- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex SIFV-EE Delayed Egress Kit – 36" or 48" | Satin Black
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex SIFV-EE Delayed Egress Kit – 36" or 48" | Satin Black
Detex SIFV-EE Delayed Egress Kit – 36" or 48" | Satin Black
$305.24
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Repair or service a compatible Detex Value Series V40 Rim Exit Device with the Detex SIFV-EE Delayed Egress Filler Kit.
Designed for V40 exit devices equipped with the EE delayed-egress function, this replacement fillerplate assembly is available for either 36" or 48" devices and is finished in Satin Black.
Additional Product Specifications and Ordering Guidance
This Detex OEM service component is intended to repair or refit the particular series shown in its description. Closely related Detex parts often differ by 36/48-inch length, strike style, dogging type, alarm function, finish or narrow/wide-stile preparation.
Exact Variant and SKU Reference
| Configured Option | Shopify SKU |
|---|---|
| size: 36" | DTX105032-3 |
| size: 48" | DTX105032-4 |
Before You Order
- Find the original device model and compare the precise Detex replacement part number and its current parts diagram.
- For fillerplates, covers or pushpad assemblies, verify physical length, mounting holes, environmental seals and connected alarm/dogging hardware.
- For strikes, latch pieces and center-case parts, verify the specific mechanical preparation, handed components and positive latch engagement.
- Check the current kit's fastener, wiring, cylinder and accessory inclusions; do not assume a complete exit device or power supply comes with a service part.
Field Installation and Performance Checks
After replacing the component, check smooth pushpad travel, secure strike engagement, proper alarm/dogging operation where fitted and free egress.
Package and Compatibility Scope
One selected Detex service part or factory kit, as identified by its SKU. Full panic devices and unrelated service kits are not included. The complete model-specific specifications remain in the original description below.
When incorporated into a complete Detex EE delayed-egress system, depressing the exit device initiates an audible alarm while the opening remains secured for the required 15-second delayed-egress period. After the delay, the door releases for egress. The alarm is approximately 100 dB, helping alert personnel and deter unauthorized exits.
Available Sizes
36" / 3' Device
-
Model: SIFV-EE-36
-
Detex Part Number: 105032-3
-
Designed for 36" V40 Rim Exit Devices
-
EE Configuration: 15/15
48" / 4' Device
-
Model: SIFV-EE-48
-
Detex Part Number: 105032-4
-
Designed for 48" V40 Rim Exit Devices
-
EE Configuration: 15/15
Detex's current parts documentation identifies 105032-3 and 105032-4 as the 3-foot and 4-foot Value Series Rim EE fillerplates respectively.
Key Features
-
Genuine Detex replacement component
-
Designed for Value Series V40 Rim Exit Devices
-
EE – Delayed Egress configuration
-
Available for 36" or 48" devices
-
Standard 15-second delayed-egress operation
-
Approximately 100 dB alarm when used as part of the complete EE system
-
Alarm triggered by exit-device operation
-
Helps deter unauthorized exits
-
Provides additional response time for facility personnel
-
Designed for 24VDC filtered and regulated power
-
Fire-alarm interface required as part of a complete EE system
-
9V battery backup provides alarm function during power failure
-
Tamper-resistant commercial design
-
Satin Black finish
-
Ideal for repair or replacement of existing delayed-egress hardware
How Delayed Egress Works
When an unauthorized exit attempt activates the Detex EE system:
-
The exit attempt initiates the alarm.
-
An approximately 100 dB audible alarm sounds.
-
The door remains secured during the standard 15-second delay.
-
After the delay expires, the device allows egress.
The delay provides facility personnel additional time to respond while still allowing required emergency egress.
The system must also interface with the building's fire-alarm system so the delayed locking function can be overridden during a fire emergency.
Typical Applications
-
Retail emergency exits
-
Stockrooms
-
Warehouses
-
Distribution centers
-
Hospitals
-
Assisted living facilities
-
Healthcare facilities
-
Schools and universities
-
Commercial buildings
-
Government facilities
-
Institutional buildings
-
Loss-prevention openings
-
Controlled-exit doors
Product Specifications
Brand: Detex
Series: Value Series
Product: SIFV-EE Delayed Egress Filler Kit
Device Type: V40 Rim Exit Device
Function: EE Delayed Egress
Delay: 15 Seconds
Alarm: Approximately 100 dB as part of complete EE system
Power Requirement: 24VDC Filtered & Regulated
Available Sizes: 36" or 48"
36" Part Number: 105032-3
48" Part Number: 105032-4
EE Configuration: 15/15
Finish: Satin Black
Application: Replacement / Service Component
Important Ordering Information
This product is the SIFV-EE fillerplate / filler kit only. It is not a complete exit device or complete delayed-egress system.
The exit device, power supply/controller, cylinder, wiring, signage, and other system components may be required depending on the existing installation and are not included unless specifically stated. Detex lists the SIFV-EE fillerplates and the 90-800 power supply as separate service components.
Before ordering, verify:
-
Existing Detex device is a V40 Rim
-
Required 36" or 48" device size
-
Existing device uses the EE delayed-egress function
-
Correct Detex part number
-
Electrical and controller requirements
-
Required finish
Delayed-egress systems must be installed and configured in accordance with applicable building, fire, accessibility, and life-safety codes.
Recently viewed products
Describe your recently viewed products here