- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex V40 EE FC3 CD Delayed Egress Rim Exit Device | 36" or 48" | 628
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex V40 EE FC3 CD Delayed Egress Rim Exit Device | 36" or 48" | 628
Detex V40 EE FC3 CD Delayed Egress Rim Exit Device | 36" or 48" | 628
$2,678.00
$1,629.08
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detex V40 EE FC3 CD Delayed Egress Rim Exit Device | 36 or 48 Inch | 628
The Detex V40 EE FC3 CD is a Grade 1 Value Series rim exit device designed for commercial and institutional openings where an approved delayed-egress arrangement is required. It combines a 15-second standard exit delay, an approximately 100 dB audible alarm, a 3-foot FC3 flexible-conduit connection, and CD cylinder dogging with a heavy-duty V40 panic bar. Both available models have the 628 / US28 Satin Aluminum finish; choose a 36-inch device for a nominal 3-foot door or a 48-inch device for a nominal 4-foot door.
Life-safety application: Delayed egress may be installed only on openings where permitted by applicable building and fire codes and approved by the authority having jurisdiction. The complete system requires the correct power, fire-alarm interface, warning signage, release sequence and commissioning.
Choose Your Device Length
| Option | Factory Configuration | CDW SKU |
|---|---|---|
| 36 in (3 ft) | V40 rim, EE delayed egress, FC3 3-foot flexible conduit, CD cylinder dogging, 628 Satin Aluminum; standard V40 99 surface strike expected—confirm the complete factory code. | DTXV40-EE-FC3-CD-36-628 |
| 48 in (4 ft) | Same EE / FC3 / CD delayed-egress features in the 48-inch length and 628 Satin Aluminum finish; standard V40 99 surface strike expected—confirm the complete factory code. | DTX-V40-EE-FC3-CD-48-628 |
The 36-inch and 48-inch options are separate device lengths, not interchangeable components. Confirm the actual door width, stile, frame, strike, available mounting clearance and manufacturer-permitted field sizing before ordering.
EE Delayed Egress — Operation and Alarm
When an armed V40 EE device senses an exit attempt through latchbolt movement, its electronics initiate the delayed-egress sequence and activate the 100 dB alarm. The standard configuration provides a 15-second release delay before permitting egress. Detex also describes visual and audible arming indicators, delayed arming after the door closes, and remote alarm signaling and bypass inputs as standard EE functions. Field options and reset behavior must be checked against the exact controller/EE board configuration and current installation instructions.
Emergency override is mandatory. The approved fire-alarm input must be connected to the appropriate Detex system power supply or factory-approved interface so that the delayed-egress lock releases during the required emergency conditions. Power-loss release behavior and the 9V alarm backup must be verified during commissioning. A 9V backup battery supports the audible alarm function only; it does not replace the required 24VDC power for normal delayed-egress operation.
Key Features
- 15-second standard delayed egress: Designed to deter unauthorized exit while following the approved emergency-release sequence.
- Integrated 100 dB alarm: Local audible warning triggered by the EE latchbolt-monitoring function.
- Grade 1 V40 platform: Commercial-duty wide-stile rim panic exit device with heavy-duty ribbed aluminum rail and angled end cap.
- 3/4-inch stainless-steel Pullman latchbolt: Deadlocking mechanical rim latch for positive engagement with the approved strike.
- CD cylinder dogging and arming: Detex's EE arrangement can use one compatible mortise cylinder for arming and cylinder dogging. A cylinder and keys are not included unless the factory order specifies a cylinder.
- FC3 conduit provision: 3-foot flexible-conduit kit mounting to the device end cap for protected low-voltage wiring between the electrified device and building connection.
- 628 Satin Aluminum finish: Clear-anodized / brushed aluminum architectural appearance on both models.
- Factory standard 99 surface strike: The V40 rim platform normally uses the 99 surface strike; verify the completed factory part number and compatible frame preparation.
- Non-handed and field-sizeable: Use the approved factory installation templates and manufacturer limits for the selected opening.
- Facility integration: Remote signal output, remote bypass, authorized reset and fire-alarm override support a properly designed commercial delayed-egress system.
Standard EE Power Supply — Important Ordering Distinction
Detex specifies a 24VDC filtered and regulated power supply for the EE system. Its standard V40 EE package includes the Detex 90-800 power supply, rated for 24VDC at 1 amp, unless the device is specifically ordered with the PS0 (Less Power Supply) option. Neither SKU in this listing identifies PS0. Confirm that the manufacturer's 90-800 power supply and required fire-alarm interface components are included in the actual purchase order and factory packing list before fulfilling either configuration.
For a replacement, shared-power or paired-door installation, the PS0 version is a different factory selection and must not be substituted without verifying the system design. External access-control readers, additional interfaces and site wiring are separate unless expressly included.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Series / Model | Value Series V40 EE FC3 CD |
| Device Type | Wide-stile rim panic exit device with delayed egress |
| Performance | ANSI/BHMA Grade 1 platform; confirm complete delayed-egress and exit-hardware listing for the opening |
| Available Device Lengths | 36 in. (nominal 3-foot door) or 48 in. (nominal 4-foot door) |
| Finish | 628 / US28 Satin Aluminum |
| Electrical Function | EE — Delayed egress with alarm and latchbolt monitoring |
| Standard Exit Delay | 15 seconds, subject to authorized setting and applicable code |
| Audible Alarm | Approximately 100 dB |
| Operating Power | 24VDC filtered and regulated |
| Standard Power Supply | Detex 90-800, 24VDC / 1A; standard EE inclusion unless PS0 is specified—confirm ordered contents |
| Backup Battery | 9V, for alarm function only during loss of primary power |
| Dogging / Alarm Arming | CD — Cylinder dogging; compatible mortise cylinder and key arrangement required |
| FC3 Power Transfer | 3-foot flexible conduit kit at end cap |
| Rim Latchbolt | 3/4-inch stainless-steel deadlocking Pullman type |
| Strike | 99 surface strike is standard for the V40 rim device; verify exact factory code |
| Handing | Non-handed, subject to approved installation |
| Standard Exterior Trim | Not included unless expressly ordered |
| Fire Rating | Not established by these standard non-F model codes; obtain listed fire-exit hardware when required |
| Weatherization | Not indicated; separate V40 weatherized configurations are available for exposed openings |
What's Included
One Detex V40 EE FC3 CD rim delayed-egress device in the selected 36-inch or 48-inch length, with the EE electronics and alarm, FC3 3-foot conduit option, CD cylinder-dogging mechanism, and standard factory V40 mechanical/mounting components. The manufacturer's standard EE package includes a 90-800 power supply and delayed-egress signage unless a factory exception such as PS0 is specified. Verify the exact 90-800 supply, strike, included signage, battery, conduit fittings and hardware against the purchase order and factory packing list.
Sold Separately
Unless explicitly part of the final factory package: mortise cylinder and keys for arming/dogging, outside-entry trim, specialized mounting components, access-control reader, additional signaling or interface equipment, site wiring, door, frame and installation services. Do not assume any extra power supplies or door-pair hardware are included beyond the documented model.
Ordering and Life-Safety Notes
Before ordering, confirm the 36-inch or 48-inch device length, 628 finish, 99 rim strike and door/frame preparation, CD cylinder keyway, FC3 wiring path, actual included EE power supply, delayed-egress signage, fire-alarm release circuit and all applicable life-safety requirements. The EE function is different from EA/EB exit alarms, EEX external-logic delayed egress, and PS0 supply-omitted devices.
Install and commission only where delayed egress is permitted by the adopted codes and the authority having jurisdiction. Test the actual audible alarm, delayed-release timing, required emergency overrides, power-loss behavior, authorization/reset functions, positive latching and unrestricted egress after required release. Do not use mechanical dogging in a way that defeats required latching on a fire-rated assembly.