{"product_id":"acsi-1550k-mdh-design-hardware-marks-usa-latch-retraction","title":"ACSI 1550K-MDH Latch Retraction Kit | Design Hardware \u0026 MARKS USA","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eElectrify compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDesign Hardware 1000 Series and MARKS USA M9900 Series exit devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACSI 1550K-MDH Motorized Latch Retraction and Dogging Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned specifically for these exit-device families, the 1550K-MDH provides quiet \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24VDC motorized latch retraction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the exit device to be remotely unlocked through an access-control system, automatic door operator, time schedule, or remote-release circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen energized, the motor retracts the latch while simultaneously depressing the pushbar into the dogged position for controlled free passage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACSI – Architectural Control Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1550K-MDH\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeries \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1550K-MD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned specifically for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDesign Hardware 1000 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMARKS USA M9900 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMotorized electric latch retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous latch retraction and electric dogging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VDC ±10%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1A maximum inrush current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e400mA maximum holding current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous-duty rated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuiet motorized operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-polarized wiring leads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOn-board diagnostic LEDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic retry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField-installable kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFactory installation available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with access-control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with automatic door operator applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL listed for compatible panic exit hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL listed for compatible fire exit hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit device sold separately\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Exit Devices\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMDH suffix\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e identifies the ACSI motor-drive kit designed specifically for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDesign Hardware\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1000 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMARKS USA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eM9900 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eACSI manufactures multiple 1550K-MD kits for different exit-device manufacturers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1550K-MDH should only be used with compatible Design Hardware 1000 or MARKS USA M9900 Series exit devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMotorized Latch Retraction\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWhen 24VDC power is applied, the internal motor retracts the exit-device latch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the opening to be electronically unlocked without requiring someone to manually depress the pushbar.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical control methods include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard readers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote release switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTime schedules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSimultaneous Electric Dogging\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH provides:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectric Latch Retraction + Electric Dogging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen energized:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe exit-device latch retracts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe pushbar depresses\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe pushbar remains in the dogged position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe opening operates in free-passage mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eWhen power is removed, the exit device returns to its normal mechanical secure condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24VDC ±10%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Inrush Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Holding Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 400mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWiring Leads:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-Polarized\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe kit requires a:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFiltered and Regulated 24VDC Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProper power-supply sizing is important for reliable operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eContinuous-Duty Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH is:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eContinuous-Duty Rated\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the exit device to remain electrically retracted for extended authorized unlock periods when connected to a properly sized power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBusiness-hours unlocking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled free passage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-traffic entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Motorized Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe motor-drive system provides quieter operation than many traditional high-inrush solenoid latch-retraction systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it a good choice for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniversities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLibraries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOffices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHotels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Retry\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH incorporates:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic Retry\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf the exit device cannot complete the latch-retraction cycle because of temporary binding or resistance, the system can automatically attempt another retraction cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDiagnostic LEDs\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOn-board LEDs help installers and service technicians with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSetup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTesting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTroubleshooting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperational verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe diagnostic system can help identify conditions involving:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSensor position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDevice binding\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMotor or control faults\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eNon-Polarized Leads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH uses:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNon-Polarized Wiring Leads\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eto simplify field wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDevice Length Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eACSI specifies allowable cutoff from the standard exit-device length.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStandard 33\" Device\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Allowable Cutoff: 1-1\/2\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStandard 42\" Device\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Allowable Cutoff: 4-1\/4\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eVerify the existing device length before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA device that has already been shortened beyond these limits may not provide enough internal space for the motor-drive assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRecommended Wire Size\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor a two-conductor 24VDC circuit, ACSI provides the following general wire-run guidance:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e70 ft – 22 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e110 ft – 20 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e180 ft – 18 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e280 ft – 16 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e450 ft – 14 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e720 ft – 12 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eActual installations should also account for voltage drop and any additional connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eManual Dogging Removal\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIf the exit device has an existing manual dogging assembly, the installation procedure calls for removal of those components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ACSI motor-drive assembly then provides the:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectric Dogging Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eField-Installable Kit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eK\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designation identifies the 1550K-MDH as a:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eField-Installable Kit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation requires access to the exit-device mechanism and pushbar assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProfessional installation by a qualified commercial-door or access-control technician is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFactory Installation Available\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe motorized latch-retraction system can also be factory installed when ordering or supplying a compatible exit device through ACSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAccess-Control Integration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH can interface with compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard readers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTimers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote release switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding management systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Door Operator Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1550K-MDH works well in properly sequenced automatic-door applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA typical operating sequence may be:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess is authorized\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1550K-MDH receives 24VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit-device latch retracts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePushbar reaches the dogged position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic operator activates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor opens\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor completes the operating cycle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit device returns to secure operation when power is removed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eProper sequencing is important so the operator does not attempt to open the door before the latch is fully retracted.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePanic \u0026amp; Fire Exit Hardware\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe ACSI 1550K-MD platform is UL listed for compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePanic exit hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire exit hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor fire-rated openings, the complete assembly must maintain its required listing, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFrame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrification kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways follow applicable life-safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniversities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOffice buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled unlock applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote-release applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-traffic commercial openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ACSI\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Architectural Control Systems, Inc.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1550K-MD\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1550K-MDH\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Motorized Latch Retraction \/ Dogging Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Manufacturers:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Design Hardware \/ MARKS USA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Series:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Design Hardware 1000 \/ MARKS USA M9900\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eVoltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24VDC ±10%\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Inrush Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Holding Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 400mA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDuty Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOperation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electric Latch Retraction and Dogging\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMotorized:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic Retry:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDiagnostic LEDs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWiring Leads:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-Polarized\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eField Installable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFactory Installable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e33\" Device Maximum Cutoff:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1-1\/2\"\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e42\" Device Maximum Cutoff:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4-1\/4\"\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePanic Hardware Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFire Exit Hardware Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eExit Device Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Exit Device Series\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDesign Hardware\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1000 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMARKS USA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eM9900 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTypical kit includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eACSI motorized latch-retraction assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDevice-specific mounting components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnecting hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWiring leads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eExact kit contents may vary with production revisions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNot Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesign Hardware or MARKS USA exit device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e24VDC power supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard reader\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypad\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control panel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door operator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl relay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFrame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation labor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Ordering Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit device is a compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDesign Hardware 1000 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMARKS USA M9900 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExact exit-device configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDevice length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAmount the device has been shortened\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting dogging configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e24VDC power-supply capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWire distance and gauge\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-operator requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePanic or fire-exit application\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1550K-MDH = Design Hardware 1000 \/ MARKS USA M9900\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not substitute another ACSI 1550K-MD suffix without confirming exact exit-device compatibility.\u003c\/span\u003e\u003c\/p\u003e","brand":"ACSI","offers":[{"title":"Default Title","offer_id":67792206758103,"sku":"1550K-MDH","price":602.7,"currency_code":"USD","in_stock":true}],"url":"https:\/\/shop.commercialdoorworx.com\/products\/acsi-1550k-mdh-design-hardware-marks-usa-latch-retraction","provider":"Commercial Door Worx","version":"1.0","type":"link"}