{"product_id":"acsi-acl9080eu-el-lmdps-electrified-mortise-lock","title":"ACSI ACL9080EU\/EL-LMDPS Electrified Mortise Lock | Latch Monitor + DPS","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eAdd electric access control and advanced lock\/door monitoring to a commercial opening with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACSI ACL9080EU\/EL-LMDPS Electrified Mortise Lock Body\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuilt around the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSchlage L9080 mortise-lock platform\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this configuration combines field-selectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFail Safe \/ Fail Secure electrification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with two important monitoring functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLM – Latch Bolt Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDPS – Door Position Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe result allows an access-control system to monitor both whether the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emain latchbolt is fully extended\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and whether the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoor itself is open or closed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe lock supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12VAC, 12VDC, 24VAC, or 24VDC operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed for commercial access-control and life-safety applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACSI – Architectural Control Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-LMDPS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBased on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSchlage L9080 mortise-lock platform\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrified commercial mortise lock body\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField-selectable electrical operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEU – Fail Secure \/ Power Unlock\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEL – Fail Safe \/ Power Lock\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLM – Latch Bolt Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDPS – Door Position Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitors full extension of the main latchbolt\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitors whether the door is open or closed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12VDC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous-duty rated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrically controlled outside trim\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical egress from inside in applicable configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKey override capability with compatible cylinder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with access-control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with compatible life-safety systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL Listed Series 1500 platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLock body only – trim and cylinder sold separately\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eLM – Latch Bolt Monitor\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLM option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a dedicated:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLatch Bolt Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe switch monitors the:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFull Extension of the Main Latchbolt\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the access-control or security system to verify that the latchbolt has extended into its normal latched position.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLM Monitoring Can Help Determine\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLatch fully extended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLatch not fully extended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor hardware not properly latched\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePossible door or strike alignment problems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor closed but latch not completely engaged\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis provides information that a standard door-position switch alone cannot provide.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eDPS – Door Position Sensor\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDPS option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e monitors the actual position of the door.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eACSI incorporates a:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Sensor in the Mortise Lock\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ethat reacts to a:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMagnet Mounted Behind the ASA Strike\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the door reaches the closed position, the magnet and sensor align and provide the appropriate monitoring signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDPS Can Monitor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor closed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor held open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor failing to return to the closed position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe access-control panel determines how these status changes are interpreted and reported.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLM + DPS Dual Monitoring\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eCombining \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLatch Bolt Monitoring and Door Position Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e gives the access-control system more detailed information about the opening.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA DPS alone can indicate that the door has returned to the frame.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe LM adds verification that the:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMain Latchbolt Has Fully Extended\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTogether, the system can better determine whether the opening is actually closed and properly latched.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eExample – Door Closed and Secure\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDPS = Door Closed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eand\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLM = Latchbolt Fully Extended\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis indicates that the door has returned to the frame and the main latch has extended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eExample – Door Closed but Not Properly Latched\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDPS = Door Closed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ebut\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLM = Latchbolt Not Fully Extended\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis may indicate:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor misalignment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBinding hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStrike alignment problems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLatch obstruction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor not completely seated in the frame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis makes the LMDPS configuration useful for openings where positive latch verification is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eField-Selectable Fail Safe \/ Fail Secure\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ACL9080EU\/EL-LMDPS provides selectable electrical locking operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEU – Fail Secure \/ Power Unlock\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIn the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFail Secure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Applied = Outside Trim Unlocked\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Removed = Outside Trim Locked\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf electrical power is lost, the exterior side remains secured.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is commonly used where maintaining security during a power failure is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEL – Fail Safe \/ Power Lock\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIn the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFail Safe\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e configuration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Applied = Outside Trim Locked\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Removed = Outside Trim Unlocked\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf electrical power is lost, the exterior side becomes unlocked.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFail-safe operation may be required for specific life-safety or emergency-release applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eFail Mode Selection\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eFail-safe versus fail-secure operation should be selected according to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding code requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire code requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLife-safety requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-alarm sequence\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuthority Having Jurisdiction requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eElectrified L9080-Style Function\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ACL9080EU\/EL-LMDPS is based on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSchlage L9080-style electrified mortise-lock function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical operation includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOutside Lever\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eElectrically locked or unlocked according to the selected EU\/EL function.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInside Lever\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides mechanical egress according to the lock configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMain Latchbolt\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMonitored by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLM switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to verify full extension.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoor Position\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMonitored by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDPS magnetic sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Cylinder\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA compatible mortise cylinder can provide mechanical override when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eMechanical Key Override\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eWhen equipped with the appropriate mortise cylinder, the latchbolt may be momentarily retracted mechanically by key even when the outside trim is electrically locked.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe lock then returns to its normal electrical control condition after mechanical key operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003e12 \/ 24 VAC or DC Operation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ACSI Series 1500 platform supports:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12VDC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the lock to integrate with a wide variety of commercial access-control power systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore installation, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC or DC operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower-supply capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWire gauge\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWire distance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower-transfer capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelay ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eContinuous-Duty Operation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe electrified lock platform is:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eContinuous-Duty Rated\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the electrical locking function to remain energized for extended periods when properly powered.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBusiness-hours unlocking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControlled office entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStairwell doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure rooms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional access control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eAccess-Control Integration\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ACL9080EU\/EL-LMDPS can interface with compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard readers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMobile credential systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTime schedules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding management systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity-management systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote release switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-alarm interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eAdvanced Door Status Monitoring\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe combination of LM and DPS can provide useful information to the access-control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on system programming, the controller may distinguish between:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor closed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor properly latched\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor closed but latch not extended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor held open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor failing to secure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis can improve troubleshooting and security reporting on monitored openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLM vs. RX\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLM option should not be confused with RX \/ Authorized Egress monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLM\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLatch Bolt Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitors whether the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emain latchbolt is fully extended\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRX \/ AE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRequest to Exit \/ Authorized Egress\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitors operation of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einside trim\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTherefore:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-RX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e monitors egress activity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-LMDPS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e monitors latchbolt extension and door position.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eDPS Installation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe DPS system uses:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic sensor incorporated into the mortise lock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnet located behind the compatible ASA strike\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCorrect magnet-to-sensor alignment is important for reliable monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eASA Strike Requirement\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBecause the DPS magnet is positioned at the strike location, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStrike type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFrame preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStrike alignment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor\/frame clearances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ebefore installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLife-Safety Integration\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eACSI Series 1500 electrified mortise locks are designed to interface with compatible life-safety systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on the opening, the system may be integrated with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire alarm controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmergency release circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStairwell unlocking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding access-control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe required operating sequence depends on the selected electrical function and applicable code requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eFire-Rated Applications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eFor a fire-rated opening, verify the complete assembly including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFrame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMortise lock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLever trim\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCylinder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStrike\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLM monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDPS monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe complete opening must maintain the required fire-door listing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eServer rooms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData centers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniversities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure offices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControlled laboratories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePharmaceutical storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmployee-only areas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStairwell openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-security commercial doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoors requiring latch-status verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled openings requiring door-position monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ACSI\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Architectural Control Systems, Inc.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ACL9080EU\/EL-LMDPS\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1500 Electric Lock\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electrified Mortise Lock Body\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePlatform:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Schlage L9080-Type Mortise Lock\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Field Selectable Fail Safe \/ Fail Secure\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eEU:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fail Secure \/ Power Unlock\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eEL:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fail Safe \/ Power Lock\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLM:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Latch Bolt Monitor\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLM Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monitors Full Extension of Main Latch\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDPS:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Door Position Sensor\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDPS Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monitors Door Open \/ Closed Position\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eVoltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12\/24VAC\/DC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDuty Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOutside Trim:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electrically Controlled\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eInside Egress:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical in Applicable Configuration\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKey Override:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e With Compatible Cylinder\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLock Body:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Included\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLever Trim:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Included\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCylinder:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Included\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eMonitoring Functions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eLM – Latch Bolt Monitor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMonitors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFull extension of the main latchbolt\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDPS – Door Position Sensor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMonitors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDoor position through a magnetic sensor in the mortise lock and magnet behind the ASA strike\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eTypical ACL9080EU\/EL-LMDPS configuration includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eACSI-modified L9080 electrified mortise lock body\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEU\/EL electrical control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLM Latch Bolt Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDPS Door Position Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDPS magnetic strike component as applicable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical connector and internal wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired internal monitoring components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eExact factory packaging may vary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eNot Included\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eUnless specifically stated:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExterior lever trim\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterior lever trim\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRose\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEscutcheon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMortise cylinder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterchangeable core\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeys\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control reader\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypad\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control panel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFrame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstallation labor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eImportant Ordering Information\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-LMDPS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFail-safe or fail-secure requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLM latch-monitoring requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDPS door-position monitoring requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC or DC operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor thickness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackset\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLever trim\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRose or escutcheon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCylinder format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFinish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eASA strike preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDPS magnet installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower-transfer requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-rating requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control inputs available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMonitoring Model Comparison\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eElectrified lock body – no added LM\/DPS monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-RX\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eElectrified lock body + Request-to-Exit monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-RXDPS\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eElectrified lock body + Request-to-Exit + Door Position Sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eACL9080EU\/EL-LMDPS\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eElectrified lock body + Latch Bolt Monitor + Door Position Sensor\u003c\/span\u003e\u003c\/p\u003e","brand":"ACSI","offers":[{"title":"Default Title","offer_id":67793450500311,"sku":"ACL9080EU\/EL-LMDPS","price":725.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/ACSI_ACL9080EU-EL.png?v=1792173772","url":"https:\/\/shop.commercialdoorworx.com\/products\/acsi-acl9080eu-el-lmdps-electrified-mortise-lock","provider":"Commercial Door Worx","version":"1.0","type":"link"}