{"product_id":"aiphone-85160210c-16awg-2-conductor-wire-1000ft","title":"Aiphone 85160210C 16 AWG 2-Conductor Wire | 1,000'","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eInstall compatible Aiphone intercom and video-entry systems with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAiphone 85160210C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a heavy-duty \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-conductor, 16 AWG solid, non-shielded, low-capacitance cable supplied in a 1,000-foot box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned specifically to meet designated Aiphone wiring requirements, the 85160210C combines larger 16 AWG solid conductors with low-capacitance construction for dependable long-distance communication and video intercom installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efoamed polyethylene conductor insulation with a PVC outer jacket\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is UL\/cUL listed for commercial low-voltage applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAiphone-approved wire\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePart number \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e85160210C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2 conductors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e16 AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolid conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNon-shielded\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow-capacitance construction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1,000-foot box\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFoamed polyethylene conductor insulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePVC outer jacket\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to match designated Aiphone wiring specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCL3 rated\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFPL rated\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ecULus CM rated\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL and cUL listed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS III compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eREACH compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMade in USA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQualifying use of Aiphone-approved wire can extend the applicable product warranty by one additional year\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Aiphone\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 85160210C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Low-Voltage Communication Cable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWire Gauge:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConductors:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConductor Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Solid\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eShielding:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-Shielded\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCable Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Low Capacitance\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1,000 ft\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConductor Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Foamed Polyethylene\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOuter Jacket:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e PVC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 14.0 pF\/ft\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDC Resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4.02 Ohms per 1,000 ft at 68°F\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCable Ratings:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CL3, FPL, cULus CM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApproximate Weight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 26 lb\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCountry of Origin:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e USA\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e16 AWG Long-Distance Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe larger \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16 AWG conductors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provide lower resistance than standard 18 or 22 AWG intercom cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAiphone specifies approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4.02 Ohms per 1,000 ft\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes the 85160210C particularly useful in compatible systems where longer wiring distances require heavier-gauge cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLow-Capacitance Construction\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 85160210C is engineered for low-capacitance communication applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts electrical characteristics help support proper:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVideo transmission\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAudio quality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntercom communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExtended wiring distances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAiphone specifies a capacitance of approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e14.0 pF\/ft\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Aiphone Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 85160210C is specified for select Aiphone systems and components requiring \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-conductor, 16 AWG low-capacitance cable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCurrent compatible equipment includes select:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJV Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJP Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVideo intercom systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLong-distance door-station wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaster-to-expansion station wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eExamples include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJVS-1V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJVS-1F\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJV-1MD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJV-1FD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJV-DV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJV-DVF\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJPS-4AED\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJPS-4AEDF\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways confirm the required wire gauge and maximum distance in the installation instructions for the exact Aiphone system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eExtended Wiring Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 85160210C is commonly specified when an installation exceeds the distance permitted with standard 18 AWG Aiphone cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIn certain legacy Aiphone video systems, the 85160210C can also be used with the appropriate long-distance adaptor to significantly extend the distance between the entrance station and master station.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual allowable distance depends on the specific system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAiphone-Approved Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAiphone intercom systems can depend on specific cable characteristics including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWire gauge\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConductor count\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolid versus stranded construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShielding\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum wiring distance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eUsing manufacturer-specified cable helps ensure proper system performance and minimizes problems associated with unsuitable substitute wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCable Ratings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 85160210C carries commercial low-voltage cable classifications including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCL3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Class 3 low-voltage circuit cable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFPL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Power-limited fire alarm cable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – General-purpose communications cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify local electrical and building-code requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Installation Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e85160210C is non-shielded and non-plenum\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not substitute it for installations specifically requiring:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShielded cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlenum-rated cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect-burial cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAT-5e or CAT-6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDifferent conductor count\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDifferent wire gauge\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor direct-burial applications, use the appropriate Aiphone direct-burial cable specified for the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial offices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApartment buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCondominiums\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools and universities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVideo intercom systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor-entry systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLong-distance intercom wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting Aiphone system upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNew Aiphone system installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAiphone Warranty Advantage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWhen qualifying Aiphone products are installed using approved Aiphone wire in accordance with manufacturer requirements, the applicable product warranty may be extended by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone additional year\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Aiphone","offers":[{"title":"Default Title","offer_id":67823386951895,"sku":"85160210C","price":559.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/AIP10087180450C_23039862-c3d4-4aef-8949-618af27ad685.png?v=1792507672","url":"https:\/\/shop.commercialdoorworx.com\/products\/aiphone-85160210c-16awg-2-conductor-wire-1000ft","provider":"Commercial Door Worx","version":"1.0","type":"link"}