{"product_id":"aiphone-ry-3dl-selective-door-release-adaptor","title":"Aiphone RY-3DL Selective Door Release Adaptor | Up to 3 Doors | Form C Relays","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eAdd selective door-release control to a compatible Aiphone intercom system with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAiphone RY-3DL Selective Door Release Adaptor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for multi-door intercom installations, the RY-3DL provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree independent Form C dry-contact relay outputs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the system to release the specific door where communication is currently established.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe relay provides both \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Open (N.O.) and Normally Closed (N.C.) contacts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for controlling compatible electric strikes, magnetic locks, and other electrified door hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAiphone RY-3DL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelective door-release adaptor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControls up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3 doors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThree Form C dry-contact relays\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReleases the door associated with the active intercom communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Open contacts for electric strikes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Closed contacts for magnetic locks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with select Aiphone JP, JF, and KB systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial access-control integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAllows one door-release command to selectively operate multiple entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for multi-door video intercom installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Aiphone\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RY-3DL\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Selective Door Release Adaptor\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Relay Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRelay Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Form C Dry Contact\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRelay Input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12–18VDC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eContact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1A at 30VDC or 50VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eContact Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Normally Open \/ Normally Closed\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWiring to Master:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 Conductors\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePower Wiring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 Conductors\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLock Wiring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 Conductors to Release Mechanism\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5-1\/2\" H x 3\" W x 1-1\/2\" D\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Multi-Door Intercom \/ Access Control\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSelective Door Release\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe RY-3DL allows a compatible Aiphone master station to control multiple entrances without requiring a separate door-release button for each door.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen communication is established with a particular door station, activating the door-release command operates the corresponding relay for that entrance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes the RY-3DL ideal for systems with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple building entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeveral controlled office doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFront and rear entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMulti-tenant facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity vestibules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial access-control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eThree Form C Relay Outputs\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe RY-3DL contains \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree independent Form C dry-contact outputs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach relay provides:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eNormally Open – N.O.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCommonly used with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efail-secure electric strikes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and locking devices that release when power is applied.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eNormally Closed – N.C.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCommonly used with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efail-safe magnetic locks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and hardware that releases when power is removed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eContact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e1A at 30VDC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1A at 50VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Aiphone Systems\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe RY-3DL is designed for compatible Aiphone systems including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJP Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eJF Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKB Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelect legacy IE Series applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the specific master station and system wiring before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eJP Series Application\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWhen used with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAiphone JP-4MED\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the RY-3DL can selectively release \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoors 1, 2, and 3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAiphone documents configurations where:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRY-3DL controls Doors 1–3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAn additional relay such as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRY-24L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can be used to control a fourth door\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe master station is programmed so the appropriate release relay becomes available based on the active door station.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWiring Distance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMaximum distance from the master station to the RY-3DL:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e22 AWG:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 165 ft\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e18 AWG:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 330 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways follow the wiring requirements for the specific Aiphone system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectric Strike Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor an electric strike, use the appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Open contact\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical compatible applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric strikes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrified latch-release hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFail-secure locking devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe lock's power supply is wired separately through the relay contact.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMagnetic Lock Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor a magnetic lock or other fail-safe device, use the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Closed contact\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe relay interrupts lock power when door release is activated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll magnetic-lock installations must comply with applicable building, fire, and life-safety codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial office buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools and universities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMulti-door entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApartment and multi-tenant facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReception desks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard-access entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVideo intercom systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Ordering Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting Aiphone intercom series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNumber of doors requiring selective release\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLock voltage and current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eN.O. or N.C. relay requirement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric strike or magnetic-lock operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExternal lock power-supply requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRY-3DL provides relay switching only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and does not serve as the primary power supply for the electric lock.\u003c\/span\u003e\u003c\/p\u003e","brand":"Aiphone","offers":[{"title":"Default Title","offer_id":67822597767383,"sku":"RY-3DL","price":144.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/AIP100RY3DL.png?v=1792503984","url":"https:\/\/shop.commercialdoorworx.com\/products\/aiphone-ry-3dl-selective-door-release-adaptor","provider":"Commercial Door Worx","version":"1.0","type":"link"}