{"product_id":"as-1-3-wire-commercial-door-safety-edge-air-switch","title":"AS-1 3-Wire Commercial Door Safety Edge Air Switch","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cstrong\u003e\u003cspan\u003ePneumatic Reversing Edge Switch | NO or NC Contacts | Interior \/ Exterior Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComplete or repair a commercial pneumatic safety-edge system with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAS-1 3-Wire Commercial Door Safety Edge Air Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for commercial overhead and rolling door operators, the AS-1 connects to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressurized pneumatic sensing hose installed inside the door's bottom seal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. When the sensing edge contacts an obstruction, displaced air activates the switch, which signals the compatible door operator to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estop or reverse door movement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe switch can be configured for either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Open (NO)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Closed (NC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation, providing flexibility for a variety of commercial door operator control circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAS-1 pneumatic air switch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for commercial door safety-edge systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3-wire configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with applicable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-wire or 3-wire operator systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelectable:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Open (NO)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Closed (NC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePneumatic air-pressure activation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einterior or exterior installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignals compatible operator to stop or reverse when the sensing edge is activated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePassive switch design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for replacement and retrofit applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enon-monitored safety-edge systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow It Works\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA pneumatic sensing hose is installed within the compatible bottom seal of the commercial door.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the door encounters an obstruction:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe bottom sensing edge compresses.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAir pressure travels through the pneumatic hose.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAS-1 air switch activates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe switch changes electrical contact state.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe compatible operator receives the signal and stops or reverses the door.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial Overhead Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRolling Steel Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSectional Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarehouse Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLoading Dock Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eService Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial Garage Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePneumatic Reversing Edges\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial Safety Edge Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e AS-1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pneumatic Safety Edge Air Switch\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWiring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3-Wire\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eContact Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Selectable NO \/ NC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eInstallation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Interior or Exterior\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eActivation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pneumatic Air Pressure\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSystem Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-Monitored\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Commercial Door Reversing Safety Edge Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe AS-1 is designed for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epneumatic commercial door sensing-edge systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and can be configured for use with appropriate 2-wire or 3-wire operator circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot intended for use with driveway treadle hoses.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause this is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enon-monitored sensing-edge component\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, verify the commercial operator model, wiring configuration, required contact logic, and current \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL 325 entrapment-protection requirements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before installation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Commercial Door Worx","offers":[{"title":"Default Title","offer_id":49545627271383,"sku":"A2536-00-Z","price":77.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/AirSwitch2.jpg?v=1786021601","url":"https:\/\/shop.commercialdoorworx.com\/products\/as-1-3-wire-commercial-door-safety-edge-air-switch","provider":"Commercial Door Worx","version":"1.0","type":"link"}