- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
BEA 10BR2-900 Wireless Logic Module – 2-Relay Automatic Door & Electric Lock Controller | 900 MHz
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
BEA 10BR2-900 Wireless Logic Module – 2-Relay Automatic Door & Electric Lock Controller | 900 MHz
BEA 10BR2-900 Wireless Logic Module – 2-Relay Automatic Door & Electric Lock Controller | 900 MHz
$240.53
$140.71
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Commercial Wireless Access Control | Integrated 900 MHz Receiver | Dual 2-Amp Relays | Adjustable Door Sequencing | 12–24VAC/VDC
The BEA 10BR2-900 Wireless Logic Module is a commercial-grade, two-relay control module featuring an integrated 900 MHz wireless receiver for automatic pedestrian door activation, electric locking hardware, and access control applications.
Designed to provide wireless MC25-style functionality, the BEA 10BR2-900 combines wireless reception and programmable relay control into a single compact unit, eliminating the need for separate wireless receiver and sequencing modules in many applications.
Featuring two 2-amp DPDT relays, the 10BR2-900 can be configured for sequenced or simultaneous relay activation. This allows compatible electric locking devices to release before an automatic door operator activates, helping coordinate proper door operation.
The module also incorporates Day/Night Access Control, allowing installers to configure secure and unrestricted wireless transmitter operation through an external dry-contact input.
Additional features include Extended Hold Mode, adjustable relay hold times, programmable sequencing delays, integrated signal-strength indication, and support for up to 75 individually programmed wireless transmitters.
Compatible with BEA's 900 MHz wireless transmitters, including handheld transmitters, push plate transmitters, retrofit transmitters, and Universal Transmitters, the BR2-900 offers a versatile solution for new commercial installations, accessibility upgrades, and automatic door retrofit projects.
Key Features & Benefits
Integrated 900 MHz Wireless Receiver
-
Built-in 900 MHz wireless technology eliminates the need for a separate receiver.
-
Operates across the 908–918 MHz frequency-hopping range.
-
Compatible with BEA 900 MHz wireless transmitters.
-
Reduces the need to run activation wiring from remote push plates to the controller.
-
Ideal for automatic door installations and retrofit projects.
Dual 2-Amp DPDT Relays
-
Features two double-pole, double-throw relays.
-
Each relay is rated for 2 amps at the specified operating voltage.
-
Supports simultaneous or sequenced relay activation.
-
Can control compatible electric locking device circuits and automatic door activation inputs.
-
Provides two switched contact sets per relay for additional wiring flexibility.
Adjustable Door Sequencing
-
Allows installers to configure the activation sequence between two relays.
-
Useful for coordinating electric lock release and automatic door operation.
-
Adjustable delay between relay activations.
-
Helps prevent the automatic door operator from attempting to open against a locked door when properly configured.
-
Suitable for single-door and selected vestibule applications.
Day/Night Access Control
-
Provides selectable secure and unrestricted transmitter operation.
-
Uses an external dry-contact input to determine the operating condition.
-
Allows individually programmed transmitters to be assigned secure or unsecure behavior.
-
Useful for entrances requiring different access permissions depending on building operating status.
-
Can be connected to compatible keyswitches, external timers, or access control equipment.
Important: The module does not contain an internal 24-hour scheduling clock. Day/Night switching requires an external control input.
Universal Transmitter Mode
-
Supports compatible BEA 900 MHz Universal Transmitters.
-
Preconfigured Universal Transmitters can operate without individual enrollment when Universal Mode is selected.
-
Reduces programming requirements in appropriate applications.
-
Allows convenient activation in accessibility-focused environments.
Note: Universal Mode and Day/Night-controlled transmitter restrictions cannot be used together in the same way as individually learned secure and unsecure transmitters. Configure the module according to the required security application.
Extended Hold Mode
-
Allows compatible wireless push plates to maintain relay activation while the transmitter remains pressed.
-
Supports applications requiring an extended activation signal.
-
Relay hold timing resumes according to the configured settings when the transmitter is released.
-
Provides operating flexibility similar to selected hardwired activation configurations.
Adjustable Relay Timing
-
Independent relay hold-time adjustments.
-
Configurable delay between relay activations.
-
Suitable for electric strike, electromagnetic lock, and automatic door operator sequencing applications.
-
Allows installers to fine-tune system operation.
Integrated LED Diagnostics
-
Blue LED indicates Relay 1 activation.
-
White LED indicates Relay 2 activation.
-
Red LED indicates radio-frequency activity and programming.
-
Tri-color signal-strength LED assists with wireless system setup and troubleshooting.
Compact Commercial Construction
-
Durable translucent white ABS housing.
-
Compact dimensions for installation in suitable electrical or control enclosures.
-
Hardwired low-voltage power connection.
-
Designed for commercial access control and automatic door equipment.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer | BEA Sensors |
| Manufacturer Part Number | 10BR2-900 |
| Product Series | BR2-900 |
| Product Type | Wireless 2-Relay Logic Module |
| Integrated Receiver | Yes |
| Wireless Technology | 900 MHz Frequency Hopping |
| Operating Frequency | 908–918 MHz |
| Supply Voltage | 12–24VAC/VDC ±10% |
| DC Current Consumption | 45 mA |
| AC Current Consumption | 75 mA |
| Power Consumption | 0.5–1.5 Watts |
| Number of Relays | 2 |
| Relay Configuration | DPDT |
| Relay Contact Rating | 2A @ 30VDC or 2A @ 24VAC |
| Relay Activation | Sequenced or Simultaneous |
| Relay 1 Hold Time | Adjustable, 0.5–10 Seconds |
| Relay 2 Hold Time | Adjustable, 0.5–10 Seconds |
| Sequencing Delay | Adjustable, 0–30 Seconds |
| Standard Transmitter Capacity | Up to 75 Programmed Transmitters |
| Universal Transmitters | No Individual Enrollment Limit in Universal Mode |
| Day/Night Input | Dry Contact |
| Auxiliary Input | Dry Contact |
| Extended Hold Mode | Yes |
| Signal Strength Indicator | Tri-Color LED |
| Operating Temperature | -22°F to 158°F |
| Housing Material | Translucent White ABS |
| Dimensions | 5.2" W x 1" H x 2.2" D |
| Certifications | FCC / IC |
| Primary Application | Automatic Door and Electric Lock Control |
How the BEA 10BR2-900 Works
The BR2-900 receives wireless activation signals from compatible BEA transmitters and operates its two relay outputs according to the selected configuration.
Application 1 – Wireless Electric Lock Release & Automatic Door Activation
Step 1 – Wireless Activation
A pedestrian presses a compatible 900 MHz wireless push plate or handheld transmitter.
Step 2 – Wireless Signal Reception
The integrated receiver recognizes the authorized transmitter signal.
Step 3 – Electric Lock Release
Relay 1 activates and switches the connected electric locking circuit according to the installation wiring.
Step 4 – Automatic Door Activation
After the configured sequencing delay, Relay 2 activates the automatic door operator input.
Step 5 – System Reset
The relays return to their normal states according to the configured hold-time settings.
This arrangement provides coordinated control of a compatible electric lock and automatic door operator.
Application 2 – Day/Night Access Control
Day/Night functionality allows the BR2-900 to distinguish between transmitters programmed for different access conditions.
Operating Configuration:
-
Secure transmitters function when the Day/Night input permits secure operation.
-
Unsecure transmitters can function in either Day/Night input state.
-
An external keyswitch, timer, or access control relay changes the Day/Night input condition.
-
The module processes received transmitter signals based on the selected configuration.
This functionality is useful for controlled commercial entrances requiring different wireless access permissions.
Application 3 – Wireless Door Sequencing
The BR2-900 can provide properly configured sequential operation of compatible door controls.
Typical applications include:
-
Electric strike release followed by automatic door activation.
-
Electromagnetic lock release followed by automatic door activation.
-
Selected vestibule door sequencing.
-
Wireless activation of multiple compatible control inputs.
Important: For bidirectional sequencing of two doors, BEA specifies that two BR2-900 modules are required.
Compatible BEA Wireless Transmitters
| Manufacturer SKU | Description |
|---|---|
| 10TD900HH1 | 900 MHz One-Button Handheld Transmitter |
| 10TD900HH2 | 900 MHz Two-Button Handheld Transmitter |
| 10TD900HH3 | 900 MHz Three-Button Handheld Transmitter |
| 10TD900HH4 | 900 MHz Four-Button Handheld Transmitter |
| 10TD900HH1U | 900 MHz Universal Handheld Transmitter |
| 10TD900PB | 900 MHz Hardwired Push Plate Transmitter |
| 10TD900TR | 900 MHz Touchless Retrofit Transmitter |
| 10EMS Series – 900 MHz | PANTHER Wireless Square Push Plates |
| 10EMR Series – 900 MHz | PANTHER Wireless Round Push Plates |
| 10LPR36-900 Series | 36" Full-Length Wireless Push Plates |
Wireless Compatibility Note: The BR2-900 operates with compatible BEA 900 MHz devices. It is not directly compatible with 300 MHz or 433 MHz transmitters.
Compatible Power Supply Accessories
| Manufacturer SKU | Description |
|---|---|
| 10PS12-24 | Low-Voltage Access Control Power Supply |
| 10PS12-24D | Low-Voltage Power Supply with Backup Circuit |
| 10PSMDR2024 | 24VDC Power Supply |
| 10PSST242 | 24V, 2-Amp Plug-In Power Supply |
| 10PSVR5T | 24VAC/VDC Power Supply |
The appropriate supply must be selected based on the complete installation and connected electrical equipment.
Recommended Applications
The BEA 10BR2-900 is ideal for:
-
Commercial automatic door installations
-
Wireless push plate activation
-
Electric strike and automatic door sequencing
-
Electromagnetic lock release control
-
ADA automatic door applications
-
Commercial access control systems
-
Secure building entrances
-
Hospitals and healthcare facilities
-
Assisted living and senior living facilities
-
Schools, colleges, and universities
-
Government and municipal buildings
-
Office buildings and corporate facilities
-
Airports and transportation facilities
-
Shopping malls and retail storefronts
-
Automatic swinging doors
-
Automatic sliding doors
-
Automatic door retrofit projects
-
Controlled-access vestibule applications
Installation & Compatibility Information
The BEA 10BR2-900 is designed for installation by qualified automatic door technicians, access control integrators, and commercial electrical contractors.
Installation Requirements:
-
Mount the controller in a suitable protected electrical enclosure.
-
Connect the appropriate 12–24VAC/VDC power source.
-
Connect Relay 1 and Relay 2 to the required door-control and electric-lock circuits.
-
Configure the desired relay activation sequence.
-
Adjust the relay hold times and sequencing delay.
-
Program compatible 900 MHz wireless transmitters.
-
Configure Day/Night or Universal Mode as applicable.
-
Test wireless operation, locking hardware release, and automatic door sequencing.
-
Verify that all connected life-safety and automatic door safety systems operate properly.
Important Electrical Information
-
The BR2-900 provides dry-contact relay outputs.
-
It does not supply operating power to the connected electric lock.
-
Locking devices require a compatible, separately provided power source.
-
Relay loads must remain within the manufacturer's specified contact ratings.
-
A compatible low-voltage power supply is required for the BR2-900 module.
-
The BR2-900 is not a complete automatic door operator or electric locking system.
-
The module must not defeat required emergency egress, fire alarm release, or automatic door safety functions.
-
Installation must comply with applicable building, electrical, accessibility, and life-safety requirements.
BEA 10BR2-900 vs. 10RD900 Wireless Receiver
| Feature | BR2-900 | RD900 |
|---|---|---|
| Wireless Frequency | 900 MHz | 900 MHz |
| Integrated Logic Control | Yes | Basic Receiver Function |
| Relay Outputs | Two DPDT Relays | Receiver Relay Output |
| Adjustable Sequencing | Yes | Not Equivalent |
| Electric Lock / Door Coordination | Yes | May Require Additional Logic |
| Day/Night Access Control | Yes | Not Equivalent |
| Best Application | Wireless Lock and Door Sequencing | Standard Wireless Door Activation |
The BR2-900 is the preferred choice when a project requires integrated wireless reception and programmable control of both an electric locking circuit and an automatic door operator.
For basic wireless push plate activation without additional sequencing requirements, a compatible standalone 900 MHz receiver may be sufficient.
Why Choose the BEA 10BR2-900?
The BEA 10BR2-900 Wireless 2-Relay Logic Module provides a compact, flexible solution for commercial automatic door and electronic locking applications.
By combining a 900 MHz wireless receiver with programmable relay sequencing, the BR2-900 can reduce the need for additional control modules and simplify selected access control installations.
Its dual 2-amp relays, adjustable timing, Day/Night functionality, Universal Transmitter compatibility, and Extended Hold Mode make it particularly useful for commercial door contractors, access control technicians, and facility maintenance personnel.
Upgrade your commercial access control installation with the BEA 10BR2-900 – combining wireless door activation, electric lock sequencing, and programmable two-relay control in one compact module.
Recently viewed products
Describe your recently viewed products here