- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
BEA 10MATRIXIIS1224 Single-Channel Inductive Loop Detector – 12–24VAC/DC | Automatic Gate & Industrial Door Vehicle Detection
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
BEA 10MATRIXIIS1224 Single-Channel Inductive Loop Detector – 12–24VAC/DC | Automatic Gate & Industrial Door Vehicle Detection
BEA 10MATRIXIIS1224 Single-Channel Inductive Loop Detector – 12–24VAC/DC | Automatic Gate & Industrial Door Vehicle Detection
$251.69
$147.24
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
BEA 10MATRIXIIS1224 Single-Channel Inductive Loop Detector – 12–24VAC/DC | Automatic Gate & Industrial Door Vehicle Detection
Commercial Vehicle Detection Controller | Automatic Sensitivity Boost | Dual Relay Outputs | Adjustable Presence & Pulse Detection | UL 508 Listed
The BEA 10MATRIXIIS1224 MATRIX Series Inductive Loop Detector is a commercial-grade, single-channel vehicle detection controller designed for automatic gates, parking barrier systems, industrial overhead doors, and commercial vehicle access applications.
Operating on 12–24VAC/VDC, the BEA 10MATRIXIIS1224 provides reliable vehicle presence detection through a properly installed inductive loop embedded in pavement or another suitable mounting surface.
Featuring Automatic Sensitivity Boost (ASB), adjustable detection sensitivity, programmable presence and pulse outputs, and two changeover relay outputs, the MATRIX Series offers flexible integration with a wide range of commercial gate operators and industrial door control systems.
The automatic sensitivity boost feature increases detection sensitivity after a vehicle is detected, helping maintain vehicle presence detection for high-clearance vehicles such as delivery trucks, commercial trailers, and industrial equipment.
The detector also supports presence detection, pulse on entry, and pulse on exit functions, allowing installers to configure the controller for specific vehicle detection and access control requirements.
With automatic loop tuning, adjustable operating frequencies, diagnostic LED indicators, and a compact plug-in design, the BEA 10MATRIXIIS1224 is ideal for warehouses, distribution centers, loading docks, parking garages, commercial gates, and industrial facilities.
Key Features & Benefits
Single-Channel Inductive Vehicle Detection
-
Designed for single-channel vehicle detection applications.
-
Monitors vehicle presence using an inductive loop detection circuit.
-
Detects changes in loop inductance caused by vehicles.
-
Provides reliable detection for commercial gates and industrial doors.
-
Suitable for vehicle entrance, exit, and presence-monitoring applications.
Automatic Sensitivity Boost (ASB)
-
Automatically increases detection sensitivity after a vehicle is detected.
-
Helps maintain detection of high-clearance vehicles.
-
Especially useful for commercial trucks, trailers, and delivery vehicles.
-
Helps reduce premature loss of vehicle presence signals.
-
Returns to the configured sensitivity after detection ends.
Adjustable Detection Sensitivity
-
Sensitivity adjustment range of 0.005% to 0.5%.
-
Allows installers to fine-tune detection settings.
-
Accommodates different loop configurations and vehicle types.
-
Helps optimize detection performance for specific installation conditions.
Multiple Vehicle Detection Modes
Presence Detection
-
Maintains the configured relay response while a vehicle is detected, subject to the selected presence-time setting.
-
Ideal for parking barriers, automatic gates, and industrial doors.
Pulse on Entry
-
Generates a momentary output when a vehicle enters the detection area.
-
Useful for activating compatible gate or industrial door controllers.
Pulse on Exit
-
Generates a momentary output when a vehicle leaves the detection area.
-
Suitable for selected vehicle counting and access control applications.
Dual Changeover Relay Outputs
-
Two potential-free changeover relay outputs.
-
Maximum contact voltage of 230VAC.
-
Maximum resistive contact current of 5 amps.
-
Supports different control functions based on selected settings.
-
Compatible with properly configured gate operators, parking barriers, and industrial door controllers.
Important: The 10MATRIXIIS1224 is a single-channel detector with two relay outputs. The relays do not provide two independently monitored vehicle detection zones.
Adjustable Vehicle Presence Time
-
Presence-time adjustment from 1 minute to infinity.
-
Allows the installer to configure maximum presence duration.
-
Useful for commercial vehicle access applications where vehicles may remain stationary over the loop.
-
Supports selected extended vehicle detection requirements.
Adjustable Pulse Output
-
Selectable 100 ms or 500 ms pulse duration.
-
Supports pulse-on-entry and pulse-on-exit applications.
-
Provides compatibility with different control input requirements.
-
Useful for automated gate and vehicle entrance sequencing.
Automatic Loop Tuning
-
Automatically tunes to the connected inductive loop.
-
Simplifies initial setup and calibration.
-
Helps compensate for changes in loop characteristics.
-
Reduces manual tuning requirements.
Adjustable Operating Frequencies
-
Detection frequency range of 20–130 kHz.
-
Four selectable frequency settings in single-loop operation.
-
Helps minimize interference from adjacent inductive loop installations.
-
Useful for commercial facilities with multiple nearby vehicle detection systems.
LED Diagnostic Indicators
-
Green LED provides power indication.
-
Red LED indicators provide loop detection and status feedback.
-
Helps installers identify activation conditions.
-
Simplifies field troubleshooting and maintenance.
Compact Commercial Design
-
Compact module measuring 1-1/2" W x 3" H x 3" D.
-
Standard 11-pin round electrical connector.
-
Suitable for installation in compatible electrical control enclosures.
-
IP40 enclosure protection.
-
UL 508 listed equipment.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer | BEA Sensors |
| Manufacturer Part Number | 10MATRIXIIS1224 |
| Product Series | MATRIX |
| Product Type | Single-Channel Inductive Loop Detector |
| Detection Technology | Inductive Loop |
| Detection Channels | 1 |
| Relay Outputs | 2 Changeover Relays |
| Operating Voltage | 12–24VAC/VDC ±10% |
| AC Supply Frequency | 48–62 Hz |
| Power Consumption | Less Than 2.5 Watts |
| Automatic Loop Tuning | Yes |
| Automatic Sensitivity Boost | Yes |
| Detection Modes | Presence / Pulse on Entry / Pulse on Exit |
| Presence Time | 1 Minute to Infinity |
| Pulse Output Duration | 100 ms or 500 ms |
| Sensitivity Range | 0.005%–0.5% |
| Detection Frequency | 20–130 kHz |
| Frequency Settings | 4 – Single-Loop Mode |
| Loop Inductance Range | 20–1000 µH |
| Reaction Time | 25 ms |
| Setup Time After Configuration | Up to 2 Seconds |
| Startup Time | Up to 8 Seconds |
| Maximum Relay Contact Voltage | 230VAC |
| Maximum Relay Contact Current | 5A Resistive |
| Connector Type | Standard 11-Pin Round (86CP11) |
| Operating Temperature | -22°F to 158°F |
| Protection Rating | IP40 |
| Product Weight | 7 oz. |
| Product Width | 1-1/2" |
| Product Height | 3" |
| Product Depth | 3" |
| Certification | UL Listed Equipment for UL 508 |
How the BEA 10MATRIXIIS1224 Works
The BEA MATRIX detector monitors electrical changes in an inductive loop installed beneath pavement or another suitable surface.
Step 1 – Vehicle Approaches
A vehicle enters the area above the installed inductive detection loop.
Step 2 – Inductance Changes
The vehicle's metal mass changes the electrical characteristics of the loop.
Step 3 – Vehicle Detection
The MATRIX controller senses the change in inductance and determines whether it exceeds the configured detection threshold.
Step 4 – Relay Activation
The detector activates the appropriate relay outputs according to its programmed settings.
Step 5 – Gate or Door Operation
The connected gate operator, parking barrier, or industrial door controller receives the detection signal and responds according to its programmed operating sequence.
Step 6 – Vehicle Departure
When the vehicle leaves the detection area, the controller responds according to its configured presence or pulse mode.
Recommended Applications
The BEA 10MATRIXIIS1224 is designed for commercial and industrial vehicle detection systems, including:
-
Automatic commercial gate systems
-
Industrial sliding and swinging gates
-
Parking garage entrance and exit systems
-
Parking barrier arms
-
Commercial rolling steel doors
-
Industrial overhead doors
-
High-speed warehouse doors
-
Distribution center vehicle entrances
-
Truck terminals
-
Loading dock access areas
-
Manufacturing facilities
-
Warehouse vehicle access points
-
Commercial parking lots
-
Industrial vehicle control systems
-
Commercial vehicle entry and exit automation
Compatible BEA Accessories
| Manufacturer Part Number | Description |
|---|---|
| 10MATRIXHARN | MATRIX 11-Pin Wiring Harness |
| 70.0262 | 11-Pin DIN-Rail Socket |
| 10PS12-24 | 12/24VDC Power Supply |
| 10PS12-24D | 12/24VDC Power Supply with Backup Circuit |
| 10PSMDR2024 | 24VDC DIN-Rail Power Supply |
| 10PSST242 | 24V, 2-Amp Plug-In Power Supply |
| 10PSVR5T | 24VAC/VDC Power Supply |
Accessory Information: Confirm which socket or connector accessories are included with the supplied detector. The optional wiring harness, external power supplies, inductive loop wire, and connected operating equipment are not part of the standalone detector listing unless specifically stated.
BEA MATRIX Model Comparison
| Model Number | Detection Channels | Operating Voltage |
|---|---|---|
| 10MATRIXIIS1224 | Single Channel | 12–24VAC/VDC |
| 10MATRIXIIS110 | Single Channel | 110–120VAC |
| 10MATRIXD1224 | Dual Channel | 12–24VAC/VDC |
| 10MATRIXD110 | Dual Channel | 110–120VAC |
Selecting the Correct MATRIX Detector
Choose the BEA 10MATRIXIIS1224 when:
-
A single vehicle detection channel is required.
-
The system provides 12–24VAC/VDC power.
-
Two relay outputs are needed for configurable control functions.
-
The installation involves a compatible industrial door or gate operator.
Choose the BEA 10MATRIXD1224 when:
-
Two independently monitored detection loops are required.
-
Separate vehicle detection zones must be monitored.
-
Directional or sequencing applications require independent loop detection.
Installation & Compatibility Information
The BEA 10MATRIXIIS1224 is designed for installation with properly configured vehicle detection loops and commercial door or gate control equipment.
Installation Requirements:
-
Install a properly designed inductive loop in the designated vehicle detection area.
-
Route the loop lead-in wiring to the detector's control enclosure.
-
Install the MATRIX detector using a compatible 11-pin socket or connection assembly.
-
Connect the appropriate 12–24VAC/VDC power supply.
-
Connect the detector relay outputs to the compatible gate, barrier, or industrial door controller.
-
Configure the required operating frequency and detection sensitivity.
-
Select the appropriate presence or pulse output settings.
-
Configure Automatic Sensitivity Boost as required.
-
Test vehicle detection and verify operation of the connected equipment.
Important Installation Notes
-
Requires an appropriately installed inductive vehicle detection loop.
-
Loop wire and field installation materials are sold separately.
-
Requires compatible 12–24VAC/VDC power.
-
Do not connect directly to 110–120VAC power.
-
Install the detector in a suitable electrical enclosure.
-
IP40 protection does not indicate waterproof construction.
-
Relay outputs must not exceed the manufacturer-rated switching capacity.
-
Proper loop installation and calibration are essential for reliable vehicle detection.
-
The detector is not a substitute for required gate or door entrapment-protection devices.
-
Follow applicable electrical, industrial door, and automatic gate safety requirements.
Why Choose the BEA 10MATRIXIIS1224?
The BEA 10MATRIXIIS1224 Single-Channel Inductive Loop Detector provides a dependable solution for commercial vehicle detection applications requiring adjustable sensitivity, automatic tuning, and flexible relay output control.
Its Automatic Sensitivity Boost helps maintain detection of commercial vehicles, while adjustable presence time and selectable pulse operation provide flexibility for different industrial door and gate systems.
With 12–24VAC/VDC operation, two changeover relay outputs, UL 508 listing, and compact construction, the MATRIX Series is well-suited for commercial door contractors, automatic gate technicians, industrial service providers, and facility maintenance departments.
Equip your commercial gate or industrial door system with the BEA 10MATRIXIIS1224 – providing reliable single-channel vehicle detection, automatic sensitivity adjustment, and commercial-grade relay control.