- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
BEA UL Double-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
BEA UL Double-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
BEA UL Double-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
$704.28
$412.00
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
BEA UL Series Double-Door Electromagnetic Locks secure two compatible door leaves with a dual-magnet assembly. Choose the correct 600 lb or 1,200 lb advertised holding force per locking position and decide whether the access system requires integrated Door Status Sensors (DS) for both leaves. These options are hardware specifications, not cosmetic finishes; the correct model must be specified for the opening and controller.
Commercial Double Maglock Features
- Two locking positions: Designed for matched double-door openings with magnetic armatures aligned at both leaves.
- Advertised holding force: Either 600 lb per door magnet or 1,200 lb per door magnet, according to factory model.
- 12/24 VDC operation: Suitable for compatible supervised commercial low-voltage access-control power supplies.
- Magnetic bond-status feedback: Monitor the holding contact/bond where supported.
- Door position feedback: The DS variations incorporate two integrated door-position sensors for monitoring the open/closed state of the separate leaves.
- LED lock status: Visual feedback for installation testing and ongoing service.
- Adjustable relock delay: 0–90 second timing per manufacturer model instructions.
- UL 294 family: Listed access-control lock product line; confirm exact certification and assembly requirements.
Exact Model Differences
10MAGLOCK6UL: 600 lb per magnet, double door, bond status monitoring. 10MAGLOCK6ULDS: 600 lb per magnet with two door status sensors. 10MAGLOCK5UL: 1,200 lb per magnet, double door, bond status monitoring. 10MAGLOCK5ULDS: 1,200 lb per magnet with two door status sensors. Rated UL static strength may differ from advertised holding capacity.
Detailed BEA Model and Variant Comparison
Choose the exact factory model below. Model number, capacity, monitoring function or mounting geometry cannot be inferred from a common product photo.
| BEA Factory SKU | Configured Option | Model-Specific Equipment |
|---|---|---|
| BEA-10MAGLOCK5ULDS | Holding Force per Door: 1200 lb each | Door Status Sensors: Yes - Two DPS | BEA 10MAGLOCK5ULDS 1200 lb double-door maglock with two door status sensors, bond monitoring, LED indicators, UL 294 listing and 12/24VDC power. |
| BEA-10MAGLOCK6UL | Holding Force per Door: 600 lb each | Door Status Sensors: No - Bond Monitor Only | BEA 10MAGLOCK6UL 600 lb double-door maglock with bond status monitoring, LED indicators, adjustable relock delay, UL 294 listing and 12/24VDC power. |
| BEA-10MAGLOCK5UL | Holding Force per Door: 1200 lb each | Door Status Sensors: No - Bond Monitor Only | BEA 10MAGLOCK5UL 1200 lb double-door maglock with bond status monitoring, LED indicators, adjustable relock delay, UL 294 listing and 12/24VDC power. |
| BEA-10MAGLOCK6ULDS | Holding Force per Door: 600 lb each | Door Status Sensors: Yes - Two DPS | BEA 10MAGLOCK6ULDS 600 lb double-door maglock with two door status sensors, bond monitoring, LED indicators, UL 294 listing and 12/24VDC power. |
Door Pair Installation Requirements
- Identify the opening: Confirm double doors, inactive/active leaves, frame header construction, door swing and whether required armatures can align properly.
- Choose holding-force class: 600 lb or 1,200 lb per door magnet according to the design and security/structural requirements.
- Choose monitoring: Bond sensors provide magnet contact information; two integrated DS door-position sensors are added only to the DS models.
- Verify electrical capacity: Confirm the model-specific combined current draw and 12/24VDC supply and wiring against current manufacturer documents.
- Specify accessories: Choose proper L/Z mounting brackets, armature plates, door closers and frame reinforcement for both leaves.
- Plan code-compliant egress: Integrate required release-on-fire, request-to-exit, emergency controls and life-safety circuitry; do not use the magnets as a substitute for approved egress hardware.
- Commission both leaves: Test each bond, each door-position indication, relock delay, power failure, authorized entry and emergency release at the installed opening.
Where Double Maglocks Are Used
Compatible commercial double doors, managed entry vestibules, institutional buildings, office access points, educational facilities, healthcare sites, high-traffic security entrances and professional facility retrofits requiring two controlled magnetic locking points.
Product scope: One selected factory BEA double-door electromagnetic lock assembly. The door frame, access controller, reader, separate power supply, emergency release station, mounting adapters and additional accessories are not automatically included. Each variant retains its original Shopify SKU, price, cost, compare-at price, stock and shipping weight. Verify actual packed shipping dimensions prior to carrier-rated shipping.
Recently viewed products
Describe your recently viewed products here