{"product_id":"bea-falcon-ex-explosion-proof-radar-sensor-standard-xl-low-mount","title":"BEA FALCON EX Explosion-Proof Industrial Radar Sensor | Standard or XL Low Mount","description":"\u003cp\u003e\u003cstrong\u003eBEA FALCON EX Explosion-Proof Industrial Motion Sensors\u003c\/strong\u003e provide microwave radar activation for qualified industrial door and vehicle-entrance installations in \u003cstrong\u003eappropriately classified hazardous areas\u003c\/strong\u003e. The two factory models share an explosion-proof \/ flame-proof industrial enclosure and a \u003cstrong\u003e100 ft cable\u003c\/strong\u003e configuration, but differ by their required \u003cstrong\u003einstallation height\u003c\/strong\u003e. Confirm the actual hazardous-area certification, hazardous material group, zone\/class\/division and local authority approval for the specific site before specifying a sensor.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Explosion-Proof Sensor Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24.150 GHz radar motion technology:\u003c\/strong\u003e Detects moving approach traffic and supplies a compatible activation signal to a properly engineered gate or door controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized explosion-proof enclosure:\u003c\/strong\u003e Intended for specific hazardous-location applications, with suitability determined by the product label and BEA current certification documents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA 4X \/ IP66 environmental protection:\u003c\/strong\u003e Weather- and corrosion-resistant enclosure when installed to the manufacturer requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 ft factory cable:\u003c\/strong\u003e Supports routing from the hazardous-area sensor to the authorized control point, subject to cable-management and hazardous-area wiring rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12–24V AC\/DC operation:\u003c\/strong\u003e Low-voltage supply per manufacturer requirements and applicable hazardous-area installation design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo mounting profiles:\u003c\/strong\u003e Standard EX for approximately 11.5–23 ft mounting, or EX XL for approximately 6.5–11.5 ft low mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial\/industrial uses:\u003c\/strong\u003e Application-specific chemical plants, industrial processing areas, logistics entrances and hazardous-location vehicle door controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard EX Versus EX XL\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10FALCONEX100 Standard:\u003c\/strong\u003e Explosion-proof FALCON radar sensor configured with 100 ft cable for approximately \u003cstrong\u003e11.5–23 ft\u003c\/strong\u003e mounting heights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10FALCONEXXL100 Low Mount:\u003c\/strong\u003e Explosion-proof low mounting model, also with 100 ft cable, for approximately \u003cstrong\u003e6.5–11.5 ft\u003c\/strong\u003e mounting heights.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Both variants are specialized hazardous-location products and are \u003cem\u003enot\u003c\/em\u003e interchangeable with ordinary IP65 FALCON, FALCON WIDE or FALCON XL devices where an explosion-proof listing is required. Confirm the full supplied model code and approved environment before purchasing.\u003c\/p\u003e\u003ch3\u003eAvailable Factory Models and Specifications\u003c\/h3\u003e\u003cp\u003eOnly these listed manufacturer configurations are included in this product family. Use the exact model and factory SKU to select the correct installation length, height or detection profile.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFactory SKU\u003c\/th\u003e\n\u003cth\u003eMounting Range\u003c\/th\u003e\n\u003cth\u003eModel-Specific Description\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBEA- 10FALCONEX100\u003c\/td\u003e\n\u003ctd\u003eEX Standard - 11.5 to 23 ft\u003c\/td\u003e\n\u003ctd\u003eBEA 10FALCONEX100 explosion-proof industrial radar motion sensor with 100 ft cable, 11.5–23 ft mounting, NEMA 4X\/IP66 and 12–24V AC\/DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBEA-10FALCONEXXL100\u003c\/td\u003e\n\u003ctd\u003eEX XL - 6.5 to 11.5 ft\u003c\/td\u003e\n\u003ctd\u003eBEA 10FALCONEXXL100 low-mount explosion-proof radar sensor with 100 ft cable, 6.5–11.5 ft mounting range, 12–24V AC\/DC and IP66 protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eTechnical Specifications and Safety\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eBEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eFALCON EX industrial microwave motion sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor Frequency\u003c\/th\u003e\n\u003ctd\u003e24.150 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure Protection\u003c\/th\u003e\n\u003ctd\u003eNEMA 4X \/ IP66 when installed to the applicable instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Cable\u003c\/th\u003e\n\u003ctd\u003e100 ft (consult current component specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e12–24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Profiles\u003c\/th\u003e\n\u003ctd\u003eEX Standard 11.5–23 ft; EX XL 6.5–11.5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation Approvals\u003c\/th\u003e\n\u003ctd\u003eVerify BEA hazardous-location certification against actual site classification and local jurisdiction requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEngineering and Installation Checklist\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify area classification:\u003c\/strong\u003e Confirm class\/division\/zone, gas or dust group, temperature requirements, applicable NEC\/CEC or local electrical code and current manufacturer certificates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose height:\u003c\/strong\u003e Select standard or XL based on actual mounting elevation and radar field geometry; these models have different detection characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck wiring:\u003c\/strong\u003e Route the supplied cable using approved fittings and conduit practices for the location, without compromising the explosion-proof assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify power and output:\u003c\/strong\u003e Ensure door\/gate controls can accept the correct low-voltage supply and relay or activation interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall securely:\u003c\/strong\u003e Mount using approved structural hardware, maintaining enclosure seals, orientation and protective clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommission carefully:\u003c\/strong\u003e Validate radar response for expected vehicles and traffic while reducing false activation from moving machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck full system safety:\u003c\/strong\u003e Provide independent door\/gate safety devices and required emergency release as specified by the complete installation.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eIndustrial Applications and Ordering Scope\u003c\/h3\u003e\u003cp\u003eFor appropriately certified chemical, fuel, manufacturing, process and warehouse environments where qualified installers require a hazardous-location rated radar door activator. This is one factory FALCON EX industrial radar sensor with its specified cable; gate operators, additional safety devices and control panels are not included unless separately identified.\u003c\/p\u003e\u003cp\u003eEvery model has its own preserved manufacturer SKU, selling price, compare-at price, cost, inventory quantity and existing shipping weight. Confirm boxed shipping weight and packaging dimensions before carrier rating.\u003c\/p\u003e","brand":"BEA","offers":[{"title":"EX Standard - 11.5 to 23 ft","offer_id":67961541394647,"sku":"BEA- 10FALCONEX100","price":1697.7,"currency_code":"USD","in_stock":true},{"title":"EX XL - 6.5 to 11.5 ft","offer_id":68003046424791,"sku":"BEA-10FALCONEXXL100","price":1697.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/BEA10010FALCONEX100.png?v=1793648051","url":"https:\/\/shop.commercialdoorworx.com\/products\/bea-falcon-ex-explosion-proof-radar-sensor-standard-xl-low-mount","provider":"Commercial Door Worx","version":"1.0","type":"link"}