- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
BEA UL Single-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
BEA UL Single-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
BEA UL Single-Door Electromagnetic Lock | 600 or 1200 lb, Door Status Options
$286.86
$167.81
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
The BEA UL Series Single-Door Electromagnetic Lock is a surface-mounted, electrically controlled magnetic locking system for a compatible commercial single-leaf door. Choose between 600 lb or 1,200 lb advertised magnetic holding force and standard bond-status monitoring or an additional integrated Door Status Sensor (DS). The two ratings describe different hardware sizes and capacities, and DS versions add door-position feedback; select the exact option required by the opening.
Standard Features Across the Series
- Electromagnetic fail-safe locking: Magnetic holding force is produced with power applied; any release on loss of power must be coordinated with the approved egress and access-control design.
- 12/24 VDC power: Dual-voltage commercial magnetic locking for compatible low-voltage, appropriately supervised power supplies.
- Bond-status monitoring: Monitors the magnetic armature/bond state on the models described, distinct from detecting whether the door is physically open or closed.
- LED indication: Visible lock/bond status indicator for service and operational checks.
- Adjustable relock delay: Manufacturer-listed adjustable 0–90 second relock timing.
- Commercial construction: UL 294 access-control hardware family; check the current certification and installed assembly for the specific model.
Holding Force and Door Status Choices
10MAGLOCK3UL: 600 lb nominal advertised holding force, single door, magnetic bond monitoring. 10MAGLOCK3ULDS: Same 600 lb lock class, with additional built-in door-position sensing. 10MAGLOCK1UL: 1,200 lb nominal advertised holding force, single door, magnetic bond monitoring. 10MAGLOCK1ULDS: Same 1,200 lb lock class with integrated door-position sensing.
Important: A door position sensor does not measure the magnetic bond. Choose DS when the controller must distinguish an open door from a closed but not securely bonded lock. Published UL static ratings can differ from advertised maximum magnetic holding force.
Detailed BEA Model and Variant Comparison
Choose the exact factory model below. Model number, capacity, monitoring function or mounting geometry cannot be inferred from a common product photo.
| BEA Factory SKU | Configured Option | Model-Specific Equipment |
|---|---|---|
| BEA-10MAGLOCK3ULDS | Holding Force: 600 lb | Door Status Sensor: Yes - Integrated DPS | BEA 10MAGLOCK3ULDS 600 lb single-door maglock with door status sensor, bond monitoring, LED indicator, 0–90 sec relock delay and 12/24VDC power. |
| BEA-10MAGLOCK1UL | Holding Force: 1200 lb | Door Status Sensor: No - Bond Monitor Only | BEA 10MAGLOCK1UL 1200 lb single-door maglock with UL 294 listing, bond status sensor, LED indicator, adjustable relock delay and 12/24VDC power. |
| BEA-10MAGLOCK1ULDS | Holding Force: 1200 lb | Door Status Sensor: Yes - Integrated DPS | BEA 10MAGLOCK1ULDS 1200 lb single-door maglock with door status sensor, bond monitoring, LED indicator, UL 294 listing and 12/24VDC operation. |
| BEA-10MAGLOCK3UL | Holding Force: 600 lb | Door Status Sensor: No - Bond Monitor Only | BEA 10MAGLOCK3UL 600 lb single-door maglock with bond status sensor, LED indicator, adjustable relock delay, UL 294 listing and 12/24VDC power. |
Commercial Applications
Suitable for professionally designed employee-access doors, commercial offices, secure internal doors, institutional buildings, healthcare facilities, educational properties, retail back-of-house openings and facility maintenance applications where an electromagnetic lock is permitted by code.
Installation and Safety Checklist
- Confirm the opening is one door leaf. Use a double-door magnet assembly for paired leaves instead.
- Select the correct 600 lb or 1,200 lb holding-force class and verify frame reinforcement, door material, armature alignment, compatible brackets and screw pattern.
- Confirm if door-position (DS) feedback is needed in addition to the standard bond-monitor relay; route the appropriate controller inputs.
- Size 12/24 VDC power supply and wiring for the selected maglock and required emergency backup or power interruption sequence.
- Confirm required REX devices, fire-alarm interfaces, emergency release, signage and other code-mandated egress measures. A magnetic lock must not obstruct free exit under applicable code.
- Test bond alignment, authorized unlock, door status indication, power failure, fire-release conditions and any programmed relock delay after installation.
Supplied scope: The selected BEA single-door maglock model. An access-control reader, power supply, separate release devices, optional mounting brackets and complete door hardware package are not included unless specifically stated. Each variant retains its original selling price, cost, compare-at price, inventory and configured shipping weight.