{"product_id":"camden-cx-91s-600-lb-magnetic-door-lock-basic-tds-options","title":"Camden CX-91S 600 lb Magnetic Door Lock | Basic or TDS Models","description":"\u003cp\u003eThe \u003cstrong\u003eCamden CX-91S Series 600 lb single-door electromagnetic lock\u003c\/strong\u003e is a surface-mounted commercial access-control maglock. Choose the basic or enhanced TDS model to match the installation and required monitoring.\u003c\/p\u003e\u003ch3\u003eModel Options\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCX-91S-06 Basic:\u003c\/strong\u003e 600 lb holding-force class single-door magnetic lock without the enhanced timer or monitoring features.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCX-91S-06TDS:\u003c\/strong\u003e 600 lb class with adjustable relock timer, door status monitoring, bond sensor\/relay, and LED indication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications and Ordering Notes\u003c\/h3\u003e\u003cp\u003eFor properly specified access-controlled commercial entrances, offices, and facility doors. Both models use frame-mounted electromagnetic holding and an armature plate. Verify the selected model's power supply requirements, mounting accessories, door preparation, applicable life-safety requirements, and wiring before ordering. Ensure compliant, independent emergency egress. A power supply and access controller are not automatically included.\u003c\/p\u003e\u003cp\u003eSelect your exact model from the variant menu. Each option retains its own SKU and pricing. Commercial Door Worx supplies Camden Door Controls commercial access-control hardware for professional installation.\u003c\/p\u003e\n\u003ch3\u003eCamden CX-91S Series: Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CX-91S series is designed for a \u003cstrong\u003esingle access-controlled door\u003c\/strong\u003e and holds the armature against an energized frame-mounted electromagnetic lock. It is not a mechanical latch or a replacement for a compatible exit-control design. Select the basic or monitoring version according to the door's supervision and relocking needs.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer \/ Series\u003c\/th\u003e\n\u003ctd\u003eCamden Door Controls CX-91S single-door magnetic lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHolding Force\u003c\/th\u003e\n\u003ctd\u003e600 lb factory-tested holding force; 500 lb UL-verified static strength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eSurface mount, single commercial door; appropriate armature and alignment required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003eField selectable 12VDC or 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003eApprox. 480 mA at 12VDC or 240 mA at 24VDC (CX-91S-06 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Protection\u003c\/th\u003e\n\u003ctd\u003eOn-board MOV surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003eWeather- and vandal-resistant assembly subject to manufacturer application limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring \/ Timer\u003c\/th\u003e\n\u003ctd\u003eAdded on CX-91S-06TDS model; basic model does not include TDS features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCamden Warranty\u003c\/th\u003e\n\u003ctd\u003eManufacturer lifetime limited warranty, subject to policy and terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompare the Two Available Models\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eFunctions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAMDEN-CX-91S-06\u003c\/td\u003e\n\u003ctd\u003eBasic 600 lb surface-mount maglock\u003c\/td\u003e\n\u003ctd\u003eStandard electromagnetic holding; no TDS timer, door status switch or monitoring LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAMDEN-CX-91S-06TDS\u003c\/td\u003e\n\u003ctd\u003e600 lb surface-mount with integrated TDS\u003c\/td\u003e\n\u003ctd\u003e5–25 second adjustable timer, door status switch, lock\/bond sensor relay, and LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommon Commercial Applications\u003c\/h3\u003e\n\u003cp\u003eUsed on compatible employee doors, office entrances, managed facilities, educational buildings, warehouses and access-controlled commercial openings when specified as part of a complete, code-compliant locking and egress system.\u003c\/p\u003e\n\u003ch3\u003eBefore Ordering and Installing\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm single-door compatibility:\u003c\/strong\u003e Verify door swing, handing, frame construction, armature placement and suitable mounting hardware or brackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect monitoring needs:\u003c\/strong\u003e Choose the TDS version when the design requires an onboard timer, door-position status, bond sensing and visual indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize the power supply:\u003c\/strong\u003e Use the rated 12\/24VDC current draw to select an appropriately supervised low-voltage supply and wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan life-safety functions:\u003c\/strong\u003e Coordinate the maglock with the approved access reader, request-to-exit equipment, fire-alarm release and emergency egress arrangements required at the opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest operation:\u003c\/strong\u003e Verify alignment, holding, emergency release and any programmed time delay under actual installation conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNot included unless separately stated:\u003c\/strong\u003e A complete access-control panel, reader, external power supply, request-to-exit station, and optional mounting accessories. Select the exact model SKU for the required monitoring package.\u003c\/p\u003e","brand":"Camden Door Controls","offers":[{"title":"CX-91S-06 Basic","offer_id":68000572145879,"sku":"CAMDEN-CX-91S-06","price":157.5,"currency_code":"USD","in_stock":true},{"title":"CX-91S-06TDS Timer and Monitoring","offer_id":68002956640471,"sku":"CAMDEN-CX-91S-06TDS","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/CX-91S-06.png?v=1793974897","url":"https:\/\/shop.commercialdoorworx.com\/products\/camden-cx-91s-600-lb-magnetic-door-lock-basic-tds-options","provider":"Commercial Door Worx","version":"1.0","type":"link"}