{"product_id":"centrios-grade-1-bluetooth-smart-exit-trim-augusta-lever-black-suede","title":"Centrios Grade 1 Bluetooth Smart Exit Trim – Augusta Lever | Black Suede","description":"\u003cp\u003e\u003cstrong\u003eCentrios Bluetooth Smart Exit Device Trim with Augusta Lever – Black Suede\u003c\/strong\u003e offers a modern, manageable way to control \u003cstrong\u003eexterior access through compatible commercial panic and fire-exit devices\u003c\/strong\u003e. With a sleek \u003cstrong\u003eAugusta lever\u003c\/strong\u003e in a durable \u003cstrong\u003eBlack Suede (BSP)\u003c\/strong\u003e finish, this smart trim combines \u003cstrong\u003eBluetooth mobile credentials\u003c\/strong\u003e, conventional mechanical key override, and business-friendly access management while preserving the separate exit device's intended free-egress function.\u003c\/p\u003e\n\u003cp\u003eDesigned for schools, commercial offices, healthcare facilities, warehouses, institutional buildings and other protected or exposed entrances, the Centrios Exit Trim features commercial Grade 1 durability, an \u003cstrong\u003eIP67-rated weather-resistant assembly\u003c\/strong\u003e, and manufacturer-published \u003cstrong\u003eUL 10C 3-hour fire-rated capability\u003c\/strong\u003e. It operates on \u003cstrong\u003efour AA alkaline batteries\u003c\/strong\u003e and includes an emergency 9V DC backup power interface to support door access when the installed batteries run low.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific ordering configuration:\u003c\/strong\u003e Distributor part number \u003cstrong\u003eCEE100TD-AU-BSP-1803-54L\u003c\/strong\u003e identifies the keyed \u003cstrong\u003eCEE100TD exit trim\u003c\/strong\u003e with \u003cstrong\u003eAU Augusta lever\u003c\/strong\u003e and \u003cstrong\u003eBSP Black Suede finish\u003c\/strong\u003e. The \u003cstrong\u003e1803-54L\u003c\/strong\u003e suffix identifies a conventional fixed-core cylinder specification in published Centrios\/ASSA ABLOY parts literature. Because this exact legacy exit-trim part number is not reproduced in the current public CEE100TD ordering table, \u003cstrong\u003econfirm the factory cylinder\/keyway, supplied keys and keying option with your distributor before release\u003c\/strong\u003e. Do not confuse this exit trim with a CEB100 cylindrical lock.\u003c\/p\u003e\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth mobile entry:\u003c\/strong\u003e Authorized users can unlock a compatible commercial exit-device opening with the Centrios mobile app, without issuing a traditional mechanical key to every user.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Grade 1 construction:\u003c\/strong\u003e Centrios exit trim is designed and tested for Grade 1 commercial-duty durability at demanding business and institutional openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAugusta lever design:\u003c\/strong\u003e Factory AU straight-style Augusta lever provides a clean architectural appearance and accessible grip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack Suede finish:\u003c\/strong\u003e BSP Black Suede powdercoat coordinates with black commercial exit devices, door closers, hinges and other door hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey-in-lever override:\u003c\/strong\u003e Keyed trim configuration offers a mechanical override in addition to enrolled digital credentials; verify the specific cylinder\/keyway with the supplier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified conventional cylinder:\u003c\/strong\u003e The provided ordering code specifies the 1803-54L fixed-core cylinder family; confirm keyway, cylinder inclusion, key count and keying details for this older ordering format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApp-based permissions:\u003c\/strong\u003e The Centrios system supports managed user permissions, access schedules and audit activity through the Centrios access-management platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCard and fob capability:\u003c\/strong\u003e Centrios cards and fobs can be used when supported and enabled by the appropriate Centrios service plan and product configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-powered smart trim:\u003c\/strong\u003e Runs on four AA alkaline batteries, with typical service life up to one year depending on use and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExterior emergency battery contacts:\u003c\/strong\u003e Designed with a 9V DC emergency backup power contact to support access when the internal AA batteries are depleted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in door position sensing:\u003c\/strong\u003e DPS provides information for supported door-state and privacy-control functions once the sensor is correctly installed and configured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassage and privacy modes:\u003c\/strong\u003e Configurable use modes offer flexibility for business entrances and areas that require managed periods of access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather-resistant housings:\u003c\/strong\u003e Centrios publishes an IP67 weather-resistance rating on both sides of the exit-trim assembly for appropriately installed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-rated door compatibility:\u003c\/strong\u003e Manufacturer lists UL 10C 3-hour fire-rated capability subject to the full listed door and exit-device installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-adjustable handing:\u003c\/strong\u003e Installer-adjustable configuration supports compatible left- or right-handed doors without having to purchase a separate trim hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad exit-device compatibility:\u003c\/strong\u003e Designed to work with supported ACCENTRA commercial exit devices and certain listed Von Duprin and other retrofit models, using appropriate mounting and monitoring parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode-conscious free egress:\u003c\/strong\u003e When paired with a correctly selected and installed exit device, the inside pushbar continues to provide mechanical egress independent of smartphone access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-year manufacturer coverage:\u003c\/strong\u003e Centrios publishes a two-year limited electronics, mechanical and finish warranty, subject to current terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentrios by ASSA ABLOY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommercial Door Worx SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTRIOS-CEE100TD-AU-BSP-1803-54L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReferenced Distributor Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCEE100TD-AU-BSP-1803-54L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentrios Exit Device Trim, CEE100TD keyed style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery-operated Bluetooth mobile-access electronic trim for compatible panic \/ fire exit devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLever Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAU – Augusta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBSP – Black Suede powdercoat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1803-54L conventional fixed-core designation as given in supplied SKU; confirm exact cylinder\/keyway with distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKey-in-lever mechanical override\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCredential Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBluetooth Low Energy mobile access through Centrios app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Credentials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentrios cards and fobs where enabled by compatible hardware and service plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccess Management\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser authorization, schedules and audit\/history capabilities through Centrios\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutside Entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuthorized electronic credential or mechanical key override\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInside Egress\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVia separate, properly installed mechanical panic\/fire exit device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \/ Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/BHMA commercial Grade 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 10C 3-hour fire rating, subject to complete opening\/listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeather Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 rated on both sides of the door when correctly installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35°F to 140°F (-37°C to 60°C), manufacturer published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessible Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADA-oriented lever hardware; comply with mounting and complete-opening requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 in. to 2-1\/4 in., manufacturer standard adjustment range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Door Stile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-1\/2 in. for typical manufacturer-approved preparations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprox. Trim Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.84 in. H × 3.60 in. W; verify installation template\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHanding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to one year, depending on use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmergency Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal 9V DC battery backup contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor Position Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported \/ typically included with factory exit-trim package; verify shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePassage \/ Privacy Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported subject to correct installation and app configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePushbar Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck whether an existing exit device contains the required pushbar monitor; retrofit kit may be necessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExit Device Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo – listing is exterior smart exit trim, not a complete panic device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Exit Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproved ACCENTRA\/Yale 6100, 6170 families; selected Von Duprin 98\/99 and other explicitly supported models – confirm model and retrofit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\/IC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer indicates applicable radio regulatory certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentrios limited 2-year electronics \/ mechanical \/ finish warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExact Packaged Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot publicly verified; measure carton before activating carrier-rated shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eIdeal Commercial Applications\u003c\/h3\u003e\n\u003cp\u003eProfessional electronic access control for \u003cstrong\u003ecommercial front and rear doors, employee access entrances, business offices, hospital service entrances, schools, university buildings, assisted-living facilities, warehouse doors, maintenance areas, exterior perimeter entrances and institutional facilities\u003c\/strong\u003e using appropriately specified rim or surface-vertical-rod exit devices. Business owners and facility teams can manage authorized entry while retaining dependable mechanical exit operation from the inside.\u003c\/p\u003e\n\u003ch3\u003eProduct and Installation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExit trim only:\u003c\/strong\u003e This listing is for the \u003cstrong\u003eCentrios electronic exit-device trim\u003c\/strong\u003e. A panic bar \/ exit device, strike, mounting or retrofit adapters, and any separately required pushbar-monitor kit are \u003cstrong\u003enot included\u003c\/strong\u003e unless explicitly supplied as part of a separately purchased bundle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck compatibility before ordering:\u003c\/strong\u003e Confirm the exact manufacturer, series, mechanism, fire-exit labeling, handing, door thickness, stile width and drilling template of the installed panic device. Do not assume every rim or surface vertical rod device is compatible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePushbar monitoring matters:\u003c\/strong\u003e Some existing exit devices require a separately installed \u003cstrong\u003ePush Bar Monitor Switch (PBMS)\u003c\/strong\u003e for proper Centrios integration. Confirm requirements for retrofit projects; the CEE100TD listing should not be assumed to include a pushbar monitoring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyed override specification:\u003c\/strong\u003e Confirm the supplied conventional 1803-54L cylinder, keyway, number of keys and keying arrangement before ordering or rekeying. Keying is not necessarily matched to existing building master-key systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery and smartphone commissioning:\u003c\/strong\u003e Install fresh approved AA alkaline batteries, enroll the trim in the Centrios mobile application, configure credentials and access schedules, test the key override and verify the emergency 9V backup process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor sensing and privacy:\u003c\/strong\u003e Install and align the door-position sensor if required for the selected function. Test scheduled access, passage mode, privacy settings and app communication at the actual doorway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP and fire listing:\u003c\/strong\u003e Install according to all current Centrios instructions. Published IP67 and UL10C claims apply to appropriately specified, installed assemblies and do not automatically certify the existing door, exit bar or frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree egress:\u003c\/strong\u003e All required fire, life-safety and emergency exit operation must remain compliant. The inside pushbar and emergency egress must function independently of mobile credential availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot a standalone Wi-Fi keypad:\u003c\/strong\u003e The trim uses Bluetooth mobile access and other supported Centrios credentials. A keypad reader, gateway, additional subscriptions or separate access-control components must be ordered when required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Packed weight has not been verified for this exact ordering code. Confirm the actual assembled carton weight and dimensions before rate shopping or dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommercial Door Worx\u003c\/strong\u003e supplies Centrios smart door hardware, electronic exit-device trim, commercial-grade exit devices, electric locking accessories and access-control components for professional installers, security integrators and building maintenance teams.\u003c\/p\u003e\u003ch3\u003eCentrios Exit Trim: Selecting the Correct Product\u003c\/h3\u003e\n\u003cp\u003eChoose this \u003cstrong\u003eCEE100TD electronic exit-device trim\u003c\/strong\u003e for a commercial opening with a \u003cem\u003emanufacturer-approved panic or fire exit device\u003c\/em\u003e when the objective is managed exterior access through the existing exit hardware. The interior pushbar must retain proper mechanical free-egress operation. This product is \u003cstrong\u003enot\u003c\/strong\u003e a complete exit bar, a conventional cylindrical lockset, or a separate wall-mounted access reader.\u003c\/p\u003e\n\u003ch3\u003eCommercial Door Compatibility Checklist\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDocument the existing exit-device brand, series, rim or vertical-rod format, latch mechanism and fire-exit rating. Verify that the specific device is compatible.\u003c\/li\u003e\n\u003cli\u003eCheck whether an existing or retrofit \u003cstrong\u003ePush Bar Monitor Switch (PBMS)\u003c\/strong\u003e is required; do not assume the monitor or associated retrofit kit is included.\u003c\/li\u003e\n\u003cli\u003eVerify door handing, thickness, minimum stile width, mounting pattern and manufacturer-approved drill template.\u003c\/li\u003e\n\u003cli\u003eConfirm the \u003cstrong\u003e1803-54L conventional keyed cylinder\u003c\/strong\u003e, exact keyway, keying and supplied key count with the distributor.\u003c\/li\u003e\n\u003cli\u003eInstall and test Centrios mobile credentials, permitted users, schedules and any supported door-position monitoring.\u003c\/li\u003e\n\u003cli\u003eTest the four-AA battery operation, emergency exterior 9V backup contacts and required mechanical egress before putting the opening into service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering distinction:\u003c\/strong\u003e For a bored cylindrical latch opening, choose the Centrios CEB100 keyed or CEB102 key-free lock family. For a separate reader operating an HES electric strike, consider the Centrios CER reader kits. The exit device, separately required retrofit hardware, optional credentials and software-plan upgrades are not automatically included. Measure the boxed trim before carrier-rated shipping.\u003c\/p\u003e","brand":"Centrios by ASSA ABLOY","offers":[{"title":"Augusta Lever \/ Black Suede \/ 1803-54L","offer_id":68002113421527,"sku":"CENTRIOS-CEE100TD-AU-BSP-1803-54L","price":682.5,"currency_code":"USD","in_stock":true}],"url":"https:\/\/shop.commercialdoorworx.com\/products\/centrios-grade-1-bluetooth-smart-exit-trim-augusta-lever-black-suede","provider":"Commercial Door Worx","version":"1.0","type":"link"}