- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Command Access ARLP88 Solenoid Latch Pullback Kit | Adams Rite 8800 | 12V / 24V
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Command Access ARLP88 Solenoid Latch Pullback Kit | Adams Rite 8800 | 12V / 24V
Command Access ARLP88 Solenoid Latch Pullback Kit | Adams Rite 8800 | 12V / 24V
$259.00
$181.30
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detailed Product Overview and Voltage Selection
The Command Access ARLP88 retrofit kit converts compatible Adams Rite 8800 Series rim exit devices to electrically controlled solenoid latch retraction without replacing the entire exit device. The existing mechanical pushpad must remain operative for normal egress. Choose the factory-specified voltage to match the control and power system; the 12V and 24V parts are not field-interchangeable.
Catalog Review – Product-Specific Notes
ARLP88 Voltage Identification
The two listed options are separate factory assemblies: ARLP88-KIT-12V and ARLP88-KIT-24V. Match the exact solenoid voltage to the supplied control power. Published series literature describes approximately 900 mA at 12V versus 450 mA at 24V; confirm current draw and AC/DC compatibility from the installation sheet supplied with the actual kit.
This retrofit is specifically intended for compatible Adams Rite 8800 rim exit devices, not a generic SVR, CVR or mortise conversion. Mechanical pushpad operation must remain functional. Optional REX monitoring, the original panic bar, the external power supply and the access controller are separate components.
Retrofit Planning, Power Requirements and Acceptance Tests
Specify this kit only for a verified Adams Rite 8800 Series rim exit device. The ARLP88 is a solenoid-powered latch pullback retrofit, not a motorized MLRK1 kit and not a complete exit device. Select the factory 12V or 24V variant to match the access-control power circuit; it is not a field-selectable-voltage product.
Voltage and Operating Considerations
- 12V kit: ARLP88-KIT-12V; published series current is approximately 900 mA at 12V. Verify current factory instructions and permitted AC/DC supply type.
- 24V kit: ARLP88-KIT-24V; published series current is approximately 450 mA at 24V. Follow the wiring and voltage instructions packaged with the actual product.
- Power supply selection: Verify momentary energization, hold requirements, upstream control output, wire gauge and cable run. The manufacturer’s specifications and the installed controller determine acceptable power and control methods.
- REX monitoring: The standard kit does not include a request-to-exit switch. Specify the compatible optional ARREXKIT-ED separately when an egress signal is required.
On-Site Verification Checklist
- Inspect the existing rim device model, pushpad, internal mounting clearance, device length and any prior modifications.
- Review the manufacturer’s supplied kit contents, fasteners, plunger alignment and door/frame wiring route before removing hardware.
- Confirm compatibility with the opening’s fire-door listing, access-control wiring and applicable mechanical-egress requirements.
- After installation, verify controlled latch retraction, positive relatching after release, unrestricted mechanical exit and expected behavior during power loss.
Ordering scope: The exit device, access controller or reader, separate power supply, door-to-frame wiring transfer and optional REX components are not included unless separately ordered.
| Model | Voltage | Published solenoid draw | Application |
|---|---|---|---|
| ARLP88-KIT-12V | 12V | 900 mA at 12V | Adams Rite 8800 rim devices |
| ARLP88-KIT-24V | 24V | 450 mA at 24V | Adams Rite 8800 rim devices |
Operation and Retrofit Considerations
- Solenoid actuation: The solenoid draws the latch back when activated by compatible access-control equipment. This is not a motorized MLRK1 latch-retraction kit.
- Voltage-specific wiring: Consult the insert supplied with the chosen model for allowable AC/DC source, wire size, voltage tolerance and maximum run; published series literature describes 18 AWG guidance.
- Device fit: Confirm Adams Rite 8800 rim configuration, internal clearances, rail length, available raceway, and the selected model's retrofit hardware before installation.
- Monitoring: The optional ARREXKIT-ED request-to-exit switch is an additional component, not part of the base kit.
- Safety: Test normal latching when unpowered, authorized powered retraction, manual exit and any applicable fire-door requirements.
Included / Not Included
Includes the chosen ARLP88 solenoid latch-pullback retrofit kit as packaged by the manufacturer. The Adams Rite 8800 exit device, external power supply, credential reader, controller, electrical power-transfer hardware, optional REX kit and field installation are separate.
Before You Order
- Match the exact factory model and variant to the project hardware schedule; model suffixes indicate important operational differences.
- Confirm electrical supply, wiring, control interface, local codes and compatibility with the installed equipment.
- Use current manufacturer wiring diagrams, cut sheets and installation instructions; test the complete door assembly after installation.
Command Access Technologies ARLP88 Series factory-configured solenoid latch pullback retrofit kit for compatible Adams Rite 8800 Series rim exit devices. Select the required 12V or 24V voltage option. The kits are factory-specific; do not assume the voltages are field-convertible. The exit device, access controller, power supply and optional REX switch are sold separately.
Choose the correct voltage
| Voltage | SKU | Published solenoid draw |
|---|---|---|
| 12V | ARLP88-KIT-12V | 900 mA at 12V (verify current specifications) |
| 24V | ARLP88-KIT-24V | 450 mA at 24V (verify current specifications) |
Both are designed for solenoid-operated latch retraction of compatible Adams Rite 8800 rim exit devices; neither is a full exit device nor a motorized MLRK1 kit. Verify wire gauge, current requirements and egress/fire-door compatibility with the instructions supplied with the selected kit.
Detailed specifications, installation guidance and inclusions by model
12V model — ARLP88-KIT-12V
Upgrade a compatible mechanical exit device for electronically controlled latch retraction with the Command Access Technologies ARLP88-KIT-12V Solenoid Latch Pullback Kit. Engineered specifically for Adams Rite 8800 Series rim exit devices, this 12V factory-configured retrofit kit uses a robust solenoid to retract the latch when electrical power is applied, making it an economical solution for select access-controlled commercial door openings. It is rim-device only and is not a complete panic bar or a motorized MLRK1 assembly.
Features and Benefits
- Adams Rite 8800 compatibility: Designed for compatible Adams Rite 8800 Series rim exit devices; verify the specific device and installation instructions before ordering.
- Solenoid-driven latch pullback: Electrically retracts the latch through a solenoid and plunger linkage rather than a motorized drive system.
- Factory-specified 12V: The manufacturer’s ARLP88 series cut sheet specifies 12VAC/DC ±10% for the 12V configuration. Follow the wiring and power-source instructions supplied with the actual 12V kit; a separate manufacturer installation insert describes the 24VDC model and should not be assumed applicable.
- Commercial access-control applications: Provides a method for powered latch retraction on appropriate push/pull, credential-controlled or authorized-access openings.
- Simple field installation: Designed to install inside an existing compatible Adams Rite rim device with a solenoid mount, plunger bracket and wiring lead; the manufacturer notes the raceway as the main drilling requirement.
- High-performance solenoid: Provides audible latch-pullback operation and is specified for extended-duration retraction where the device and power supply support it.
- Mechanical egress retained: The exit device's normal mechanical pushpad action remains available when correctly installed. Verify code compliance of the completed door assembly.
- Optional REX accessory: The manufacturer lists a separately available ARREXKIT-ED request-to-exit upgrade; it is not included with this base kit.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer SKU | ARLP88-KIT-12V |
| Product Series | ARLP88-KIT Solenoid Latch Pullback |
| Application | Adams Rite 8800 Series rim exit devices only |
| Device Configuration | Rim exit device; not SVR, CVR or mortise unless specifically approved |
| Operating Mechanism | Electric solenoid latch retraction / latch pullback |
| Nominal Voltage | 12V (current manufacturer insert specifies 12VDC ±10%; follow actual included instructions) |
| Published Solenoid Amperage | 900 mA at 12V per ARLP88 manufacturer series cut sheet; confirm current factory ratings |
| Minimum Wire Gauge | 18 AWG minimum per ARLP88 manufacturer series cut sheet; confirm with the supplied 12V instructions |
| Published Maximum Wire Run | Up to 300 ft with 18 AWG wire under the older manufacturer's stated conditions; actual allowable length depends on power-source and wiring design |
| Nominal Product Weight | Approximately 2 lb per manufacturer cut sheet; packaged shipping weight may differ |
| Available Voltage Family | Separate 12V and 24V factory configurations; this SKU is the 12V model |
| Warranty | Manufacturer three-year limited warranty; consult current terms |
| Request-to-Exit | Not included; optional ARREXKIT-ED available separately |
Common Commercial Applications
Adams Rite 8800 rim exit devices at commercial storefronts, institutional facilities, offices, healthcare administrative buildings, schools and other specified access-control openings where an electrified latch-pullback retrofit is approved.
Installation and Compatibility Guidelines
- Verify the installed panic device is an Adams Rite 8800 Series rim exit device, with appropriate internal components, device length and hardware conditions.
- Confirm a 12V ARLP88 solenoid kit is appropriate; the 24V model is a separate factory part and should not be assumed field convertible.
- Check the manufacturer's current insert installation guide, wiring restrictions, power-supply requirements, and door raceway or power-transfer details before installation.
- Mount the solenoid and plunger hardware as instructed, route the supplied lead and connect the approved power source with the required wire gauge.
- Test energized latch retraction, return to normal latching when power is removed, manual exit operation and integration with any access-control controls.
- Confirm applicable fire-door, listing, emergency-egress and accessibility requirements before altering the exit-device hardware.
What Is Included
Manufacturer's ARLP88-KIT-12V retrofit kit. Manufacturer kit documentation describes a solenoid mount, plunger bracket, silicone washer, power connector and wiring lead; confirm the supplied cable length, fasteners and part revision for the 12V kit.
Not Included
The Adams Rite 8800 exit device itself, access-control reader or controller, separate power supply, door wiring transfer, external credential hardware and optional request-to-exit upgrade are not included. This listing is for the 12V rim solenoid kit only.
24V model — ARLP88-KIT-24V
Upgrade a compatible mechanical exit device for electronically controlled latch retraction with the Command Access Technologies ARLP88-KIT-24V Solenoid Latch Pullback Kit. Engineered specifically for Adams Rite 8800 Series rim exit devices, this 24V factory-configured retrofit kit uses a robust solenoid to retract the latch when electrical power is applied, making it an economical solution for select access-controlled commercial door openings. It is rim-device only and is not a complete panic bar or a motorized MLRK1 assembly.
Features and Benefits
- Adams Rite 8800 compatibility: Designed for compatible Adams Rite 8800 Series rim exit devices; verify the specific device and installation instructions before ordering.
- Solenoid-driven latch pullback: Electrically retracts the latch through a solenoid and plunger linkage rather than a motorized drive system.
- Factory-specified 24V: The 24V configuration uses nominal 24VDC ±10% per current insert instructions. The manufacturer's older series cut sheet references 24VAC/DC configurations; follow the instructions supplied with the actual kit and verify power-source compatibility before installation.
- Commercial access-control applications: Provides a method for powered latch retraction on appropriate push/pull, credential-controlled or authorized-access openings.
- Simple field installation: Designed to install inside an existing compatible Adams Rite rim device with a solenoid mount, plunger bracket and wiring lead; the manufacturer notes the raceway as the main drilling requirement.
- High-performance solenoid: Provides audible latch-pullback operation and is specified for extended-duration retraction where the device and power supply support it.
- Mechanical egress retained: The exit device's normal mechanical pushpad action remains available when correctly installed. Verify code compliance of the completed door assembly.
- Optional REX accessory: The manufacturer lists a separately available ARREXKIT-ED request-to-exit upgrade; it is not included with this base kit.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer SKU | ARLP88-KIT-24V |
| Product Series | ARLP88-KIT Solenoid Latch Pullback |
| Application | Adams Rite 8800 Series rim exit devices only |
| Device Configuration | Rim exit device; not SVR, CVR or mortise unless specifically approved |
| Operating Mechanism | Electric solenoid latch retraction / latch pullback |
| Nominal Voltage | 24V (current manufacturer insert specifies 24VDC ±10%; follow actual included instructions) |
| Published Solenoid Amperage | 450 mA at 24V per ARLP88 manufacturer series cut sheet; confirm current factory ratings |
| Minimum Wire Gauge | 18 AWG per current manufacturer insert instructions |
| Published Maximum Wire Run | Up to 300 ft with 18 AWG wire under the older manufacturer's stated conditions; actual allowable length depends on power-source and wiring design |
| Nominal Product Weight | Approximately 2 lb per manufacturer cut sheet; packaged shipping weight may differ |
| Available Voltage Family | Separate 12V and 24V factory configurations; this SKU is the 24V model |
| Warranty | Manufacturer three-year limited warranty; consult current terms |
| Request-to-Exit | Not included; optional ARREXKIT-ED available separately |
Common Commercial Applications
Adams Rite 8800 rim exit devices at commercial storefronts, institutional facilities, offices, healthcare administrative buildings, schools and other specified access-control openings where an electrified latch-pullback retrofit is approved.
Installation and Compatibility Guidelines
- Verify the installed panic device is an Adams Rite 8800 Series rim exit device, with appropriate internal components, device length and hardware conditions.
- Confirm a 24V ARLP88 solenoid kit is appropriate; the 12V model is a separate factory part and should not be assumed field convertible.
- Check the manufacturer's current insert installation guide, wiring restrictions, power-supply requirements, and door raceway or power-transfer details before installation.
- Mount the solenoid and plunger hardware as instructed, route the supplied lead and connect the approved power source with the required wire gauge.
- Test energized latch retraction, return to normal latching when power is removed, manual exit operation and integration with any access-control controls.
- Confirm applicable fire-door, listing, emergency-egress and accessibility requirements before altering the exit-device hardware.
What Is Included
Manufacturer's ARLP88-KIT-24V retrofit kit. The published insert instructions identify a solenoid mount with four screws, plunger bracket, silicone washer, power connector and an 8-ft lead; verify actual carton contents and part revisions on receipt.
Not Included
The Adams Rite 8800 exit device itself, access-control reader or controller, separate power supply, door wiring transfer, external credential hardware and optional request-to-exit upgrade are not included. This listing is for the 24V rim solenoid kit only.
Recently viewed products
Describe your recently viewed products here