{"product_id":"command-access-arlp88-solenoid-latch-pullback-kit-adams-rite-8800","title":"Command Access ARLP88 Solenoid Latch Pullback Kit | Adams Rite 8800 | 12V \/ 24V","description":"\u003ch2\u003eDetailed Product Overview and Voltage Selection\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eCommand Access ARLP88\u003c\/strong\u003e retrofit kit converts compatible Adams Rite 8800 Series \u003cstrong\u003erim\u003c\/strong\u003e exit devices to electrically controlled solenoid latch retraction without replacing the entire exit device. The existing mechanical pushpad must remain operative for normal egress. Choose the factory-specified voltage to match the control and power system; the 12V and 24V parts are not field-interchangeable.\u003c\/p\u003e\u003ch3\u003eCatalog Review – Product-Specific Notes\u003c\/h3\u003e\u003ch3\u003eARLP88 Voltage Identification\u003c\/h3\u003e\u003cp\u003eThe two listed options are separate factory assemblies: \u003cstrong\u003eARLP88-KIT-12V\u003c\/strong\u003e and \u003cstrong\u003eARLP88-KIT-24V\u003c\/strong\u003e. Match the exact solenoid voltage to the supplied control power. Published series literature describes approximately 900 mA at 12V versus 450 mA at 24V; confirm current draw and AC\/DC compatibility from the installation sheet supplied with the actual kit.\u003c\/p\u003e\u003cp\u003eThis retrofit is specifically intended for compatible \u003cstrong\u003eAdams Rite 8800 rim exit devices\u003c\/strong\u003e, not a generic SVR, CVR or mortise conversion. Mechanical pushpad operation must remain functional. Optional REX monitoring, the original panic bar, the external power supply and the access controller are separate components.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eRetrofit Planning, Power Requirements and Acceptance Tests\u003c\/h3\u003e\n\u003cp\u003eSpecify this kit only for a verified \u003cstrong\u003eAdams Rite 8800 Series rim exit device\u003c\/strong\u003e. The ARLP88 is a solenoid-powered latch pullback retrofit, not a motorized MLRK1 kit and not a complete exit device. Select the factory 12V or 24V variant to match the access-control power circuit; it is not a field-selectable-voltage product.\u003c\/p\u003e\n\u003ch4\u003eVoltage and Operating Considerations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12V kit:\u003c\/strong\u003e ARLP88-KIT-12V; published series current is approximately 900 mA at 12V. Verify current factory instructions and permitted AC\/DC supply type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V kit:\u003c\/strong\u003e ARLP88-KIT-24V; published series current is approximately 450 mA at 24V. Follow the wiring and voltage instructions packaged with the actual product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply selection:\u003c\/strong\u003e Verify momentary energization, hold requirements, upstream control output, wire gauge and cable run. The manufacturer’s specifications and the installed controller determine acceptable power and control methods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREX monitoring:\u003c\/strong\u003e The standard kit does not include a request-to-exit switch. Specify the compatible optional ARREXKIT-ED separately when an egress signal is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOn-Site Verification Checklist\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eInspect the existing rim device model, pushpad, internal mounting clearance, device length and any prior modifications.\u003c\/li\u003e\n\u003cli\u003eReview the manufacturer’s supplied kit contents, fasteners, plunger alignment and door\/frame wiring route before removing hardware.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with the opening’s fire-door listing, access-control wiring and applicable mechanical-egress requirements.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify controlled latch retraction, positive relatching after release, unrestricted mechanical exit and expected behavior during power loss.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering scope:\u003c\/strong\u003e The exit device, access controller or reader, separate power supply, door-to-frame wiring transfer and optional REX components are not included unless separately ordered.\u003c\/p\u003e\u003c\/section\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003ePublished solenoid draw\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eARLP88-KIT-12V\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e900 mA at 12V\u003c\/td\u003e\n\u003ctd\u003eAdams Rite 8800 rim devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARLP88-KIT-24V\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003ctd\u003e450 mA at 24V\u003c\/td\u003e\n\u003ctd\u003eAdams Rite 8800 rim devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eOperation and Retrofit Considerations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid actuation:\u003c\/strong\u003e The solenoid draws the latch back when activated by compatible access-control equipment. This is not a motorized MLRK1 latch-retraction kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage-specific wiring:\u003c\/strong\u003e Consult the insert supplied with the chosen model for allowable AC\/DC source, wire size, voltage tolerance and maximum run; published series literature describes 18 AWG guidance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice fit:\u003c\/strong\u003e Confirm Adams Rite 8800 rim configuration, internal clearances, rail length, available raceway, and the selected model's retrofit hardware before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e The optional ARREXKIT-ED request-to-exit switch is an additional component, not part of the base kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Test normal latching when unpowered, authorized powered retraction, manual exit and any applicable fire-door requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded \/ Not Included\u003c\/h3\u003e\u003cp\u003eIncludes the chosen ARLP88 solenoid latch-pullback retrofit kit as packaged by the manufacturer. The Adams Rite 8800 exit device, external power supply, credential reader, controller, electrical power-transfer hardware, optional REX kit and field installation are separate.\u003c\/p\u003e\u003ch3\u003eBefore You Order\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the exact factory model and variant to the project hardware schedule; model suffixes indicate important operational differences.\u003c\/li\u003e\n\u003cli\u003eConfirm electrical supply, wiring, control interface, local codes and compatibility with the installed equipment.\u003c\/li\u003e\n\u003cli\u003eUse current manufacturer wiring diagrams, cut sheets and installation instructions; test the complete door assembly after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eCommand Access Technologies ARLP88 Series\u003c\/strong\u003e factory-configured solenoid latch pullback retrofit kit for compatible \u003cstrong\u003eAdams Rite 8800 Series rim exit devices\u003c\/strong\u003e. Select the required 12V or 24V voltage option. The kits are factory-specific; do not assume the voltages are field-convertible. The exit device, access controller, power supply and optional REX switch are sold separately.\u003c\/p\u003e\u003ch3\u003eChoose the correct voltage\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003ePublished solenoid draw\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003eARLP88-KIT-12V\u003c\/td\u003e\n\u003ctd\u003e900 mA at 12V (verify current specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003ctd\u003eARLP88-KIT-24V\u003c\/td\u003e\n\u003ctd\u003e450 mA at 24V (verify current specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBoth are designed for solenoid-operated latch retraction of compatible Adams Rite 8800 rim exit devices; neither is a full exit device nor a motorized MLRK1 kit. Verify wire gauge, current requirements and egress\/fire-door compatibility with the instructions supplied with the selected kit.\u003c\/p\u003e\u003ch3\u003eDetailed specifications, installation guidance and inclusions by model\u003c\/h3\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003e12V model — ARLP88-KIT-12V\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eUpgrade a compatible mechanical exit device for electronically controlled latch retraction with the \u003cstrong\u003eCommand Access Technologies ARLP88-KIT-12V Solenoid Latch Pullback Kit\u003c\/strong\u003e. Engineered specifically for \u003cstrong\u003eAdams Rite 8800 Series rim exit devices\u003c\/strong\u003e, this \u003cstrong\u003e12V factory-configured retrofit kit\u003c\/strong\u003e uses a robust solenoid to retract the latch when electrical power is applied, making it an economical solution for select access-controlled commercial door openings. It is \u003cstrong\u003erim-device only\u003c\/strong\u003e and is not a complete panic bar or a motorized MLRK1 assembly.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdams Rite 8800 compatibility:\u003c\/strong\u003e Designed for compatible Adams Rite 8800 Series \u003cstrong\u003erim\u003c\/strong\u003e exit devices; verify the specific device and installation instructions before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid-driven latch pullback:\u003c\/strong\u003e Electrically retracts the latch through a solenoid and plunger linkage rather than a motorized drive system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-specified 12V:\u003c\/strong\u003e The manufacturer’s ARLP88 series cut sheet specifies \u003cstrong\u003e12VAC\/DC ±10%\u003c\/strong\u003e for the 12V configuration. Follow the wiring and power-source instructions supplied with the actual 12V kit; a separate manufacturer installation insert describes the 24VDC model and should not be assumed applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial access-control applications:\u003c\/strong\u003e Provides a method for powered latch retraction on appropriate push\/pull, credential-controlled or authorized-access openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple field installation:\u003c\/strong\u003e Designed to install inside an existing compatible Adams Rite rim device with a solenoid mount, plunger bracket and wiring lead; the manufacturer notes the raceway as the main drilling requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-performance solenoid:\u003c\/strong\u003e Provides audible latch-pullback operation and is specified for extended-duration retraction where the device and power supply support it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical egress retained:\u003c\/strong\u003e The exit device's normal mechanical pushpad action remains available when correctly installed. Verify code compliance of the completed door assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional REX accessory:\u003c\/strong\u003e The manufacturer lists a separately available \u003cstrong\u003eARREXKIT-ED\u003c\/strong\u003e request-to-exit upgrade; it is \u003cstrong\u003enot included\u003c\/strong\u003e with this base kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCommand Access Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eARLP88-KIT-12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Series\u003c\/th\u003e\n\u003ctd\u003eARLP88-KIT Solenoid Latch Pullback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eAdams Rite 8800 Series rim exit devices only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Configuration\u003c\/th\u003e\n\u003ctd\u003eRim exit device; not SVR, CVR or mortise unless specifically approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Mechanism\u003c\/th\u003e\n\u003ctd\u003eElectric solenoid latch retraction \/ latch pullback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd\u003e12V (current manufacturer insert specifies 12VDC ±10%; follow actual included instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Solenoid Amperage\u003c\/th\u003e\n\u003ctd\u003e900 mA at 12V per ARLP88 manufacturer series cut sheet; confirm current factory ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Wire Gauge\u003c\/th\u003e\n\u003ctd\u003e18 AWG minimum per ARLP88 manufacturer series cut sheet; confirm with the supplied 12V instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Maximum Wire Run\u003c\/th\u003e\n\u003ctd\u003eUp to 300 ft with 18 AWG wire under the older manufacturer's stated conditions; actual allowable length depends on power-source and wiring design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Product Weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 2 lb per manufacturer cut sheet; packaged shipping weight may differ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable Voltage Family\u003c\/th\u003e\n\u003ctd\u003eSeparate 12V and 24V factory configurations; this SKU is the 12V model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eManufacturer three-year limited warranty; consult current terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequest-to-Exit\u003c\/th\u003e\n\u003ctd\u003eNot included; optional ARREXKIT-ED available separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommon Commercial Applications\u003c\/h3\u003e\n\u003cp\u003eAdams Rite 8800 rim exit devices at commercial storefronts, institutional facilities, offices, healthcare administrative buildings, schools and other specified access-control openings where an electrified latch-pullback retrofit is approved.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Compatibility Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the installed panic device is an \u003cstrong\u003eAdams Rite 8800 Series rim exit device\u003c\/strong\u003e, with appropriate internal components, device length and hardware conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm a \u003cstrong\u003e12V\u003c\/strong\u003e ARLP88 solenoid kit is appropriate; the 24V model is a separate factory part and should not be assumed field convertible.\u003c\/li\u003e\n\u003cli\u003eCheck the manufacturer's current insert installation guide, wiring restrictions, power-supply requirements, and door raceway or power-transfer details before installation.\u003c\/li\u003e\n\u003cli\u003eMount the solenoid and plunger hardware as instructed, route the supplied lead and connect the approved power source with the required wire gauge.\u003c\/li\u003e\n\u003cli\u003eTest energized latch retraction, return to normal latching when power is removed, manual exit operation and integration with any access-control controls.\u003c\/li\u003e\n\u003cli\u003eConfirm applicable fire-door, listing, emergency-egress and accessibility requirements before altering the exit-device hardware.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\n\u003cp\u003eManufacturer's \u003cstrong\u003eARLP88-KIT-12V\u003c\/strong\u003e retrofit kit. Manufacturer kit documentation describes a \u003cstrong\u003esolenoid mount, plunger bracket, silicone washer, power connector and wiring lead\u003c\/strong\u003e; confirm the supplied cable length, fasteners and part revision for the 12V kit.\u003c\/p\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAdams Rite 8800 exit device\u003c\/strong\u003e itself, access-control reader or controller, separate power supply, door wiring transfer, external credential hardware and optional request-to-exit upgrade are not included. This listing is for the \u003cstrong\u003e12V rim solenoid kit only\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003e24V model — ARLP88-KIT-24V\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eUpgrade a compatible mechanical exit device for electronically controlled latch retraction with the \u003cstrong\u003eCommand Access Technologies ARLP88-KIT-24V Solenoid Latch Pullback Kit\u003c\/strong\u003e. Engineered specifically for \u003cstrong\u003eAdams Rite 8800 Series rim exit devices\u003c\/strong\u003e, this \u003cstrong\u003e24V factory-configured retrofit kit\u003c\/strong\u003e uses a robust solenoid to retract the latch when electrical power is applied, making it an economical solution for select access-controlled commercial door openings. It is \u003cstrong\u003erim-device only\u003c\/strong\u003e and is not a complete panic bar or a motorized MLRK1 assembly.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdams Rite 8800 compatibility:\u003c\/strong\u003e Designed for compatible Adams Rite 8800 Series \u003cstrong\u003erim\u003c\/strong\u003e exit devices; verify the specific device and installation instructions before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid-driven latch pullback:\u003c\/strong\u003e Electrically retracts the latch through a solenoid and plunger linkage rather than a motorized drive system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-specified 24V:\u003c\/strong\u003e The 24V configuration uses nominal \u003cstrong\u003e24VDC ±10%\u003c\/strong\u003e per current insert instructions. The manufacturer's older series cut sheet references 24VAC\/DC configurations; follow the instructions supplied with the actual kit and verify power-source compatibility before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial access-control applications:\u003c\/strong\u003e Provides a method for powered latch retraction on appropriate push\/pull, credential-controlled or authorized-access openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple field installation:\u003c\/strong\u003e Designed to install inside an existing compatible Adams Rite rim device with a solenoid mount, plunger bracket and wiring lead; the manufacturer notes the raceway as the main drilling requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-performance solenoid:\u003c\/strong\u003e Provides audible latch-pullback operation and is specified for extended-duration retraction where the device and power supply support it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical egress retained:\u003c\/strong\u003e The exit device's normal mechanical pushpad action remains available when correctly installed. Verify code compliance of the completed door assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional REX accessory:\u003c\/strong\u003e The manufacturer lists a separately available \u003cstrong\u003eARREXKIT-ED\u003c\/strong\u003e request-to-exit upgrade; it is \u003cstrong\u003enot included\u003c\/strong\u003e with this base kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCommand Access Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eARLP88-KIT-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Series\u003c\/th\u003e\n\u003ctd\u003eARLP88-KIT Solenoid Latch Pullback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eAdams Rite 8800 Series rim exit devices only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Configuration\u003c\/th\u003e\n\u003ctd\u003eRim exit device; not SVR, CVR or mortise unless specifically approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Mechanism\u003c\/th\u003e\n\u003ctd\u003eElectric solenoid latch retraction \/ latch pullback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd\u003e24V (current manufacturer insert specifies 24VDC ±10%; follow actual included instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Solenoid Amperage\u003c\/th\u003e\n\u003ctd\u003e450 mA at 24V per ARLP88 manufacturer series cut sheet; confirm current factory ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Wire Gauge\u003c\/th\u003e\n\u003ctd\u003e18 AWG per current manufacturer insert instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Maximum Wire Run\u003c\/th\u003e\n\u003ctd\u003eUp to 300 ft with 18 AWG wire under the older manufacturer's stated conditions; actual allowable length depends on power-source and wiring design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Product Weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 2 lb per manufacturer cut sheet; packaged shipping weight may differ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable Voltage Family\u003c\/th\u003e\n\u003ctd\u003eSeparate 12V and 24V factory configurations; this SKU is the 24V model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eManufacturer three-year limited warranty; consult current terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequest-to-Exit\u003c\/th\u003e\n\u003ctd\u003eNot included; optional ARREXKIT-ED available separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommon Commercial Applications\u003c\/h3\u003e\n\u003cp\u003eAdams Rite 8800 rim exit devices at commercial storefronts, institutional facilities, offices, healthcare administrative buildings, schools and other specified access-control openings where an electrified latch-pullback retrofit is approved.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Compatibility Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the installed panic device is an \u003cstrong\u003eAdams Rite 8800 Series rim exit device\u003c\/strong\u003e, with appropriate internal components, device length and hardware conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm a \u003cstrong\u003e24V\u003c\/strong\u003e ARLP88 solenoid kit is appropriate; the 12V model is a separate factory part and should not be assumed field convertible.\u003c\/li\u003e\n\u003cli\u003eCheck the manufacturer's current insert installation guide, wiring restrictions, power-supply requirements, and door raceway or power-transfer details before installation.\u003c\/li\u003e\n\u003cli\u003eMount the solenoid and plunger hardware as instructed, route the supplied lead and connect the approved power source with the required wire gauge.\u003c\/li\u003e\n\u003cli\u003eTest energized latch retraction, return to normal latching when power is removed, manual exit operation and integration with any access-control controls.\u003c\/li\u003e\n\u003cli\u003eConfirm applicable fire-door, listing, emergency-egress and accessibility requirements before altering the exit-device hardware.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\n\u003cp\u003eManufacturer's \u003cstrong\u003eARLP88-KIT-24V\u003c\/strong\u003e retrofit kit. The published insert instructions identify a \u003cstrong\u003esolenoid mount with four screws, plunger bracket, silicone washer, power connector and an 8-ft lead\u003c\/strong\u003e; verify actual carton contents and part revisions on receipt.\u003c\/p\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAdams Rite 8800 exit device\u003c\/strong\u003e itself, access-control reader or controller, separate power supply, door wiring transfer, external credential hardware and optional request-to-exit upgrade are not included. This listing is for the \u003cstrong\u003e24V rim solenoid kit only\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/details\u003e","brand":"Command Access Technologies","offers":[{"title":"24V","offer_id":68022907666647,"sku":"ARLP88-KIT-24V","price":181.3,"currency_code":"USD","in_stock":true},{"title":"12V","offer_id":68030717395159,"sku":"ARLP88-KIT-12V","price":181.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/COM_ARLP88-KIT.png?v=1794248478","url":"https:\/\/shop.commercialdoorworx.com\/products\/command-access-arlp88-solenoid-latch-pullback-kit-adams-rite-8800","provider":"Commercial Door Worx","version":"1.0","type":"link"}