- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Command Access MLRK1 Motorized Latch Retraction Retrofit Kits | Select Exit Device
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Command Access MLRK1 Motorized Latch Retraction Retrofit Kits | Select Exit Device
Command Access MLRK1 Motorized Latch Retraction Retrofit Kits | Select Exit Device
$631.00
$441.70
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Motorized Latch Retraction — Detailed Compatibility Guide
Command Access MLRK1 Series kits add electrically controlled motorized latch retraction to a compatible existing commercial exit device. The available variants are device-specific factory retrofit assemblies; the SKU and exit-device series must match the installed hardware. A 24VDC control and properly sized power circuit are required, and the mechanical exit function must remain available in accordance with applicable requirements.
Catalog Review – Product-Specific Notes
Exit Device Identification Before Selecting a Retrofit
Read the manufacturer, model and rail identification directly from the existing exit device. A manufacturer name alone is insufficient: different rim, mortise and vertical-rod versions can require different MLRK1 kits. Use the exact SKU from the compatibility menu and compare it with the current Command Access installation sheet.
REX distinction: MLRK1-HAG-REX is a distinct Hager configuration. Other listed kits should not be represented as including a request-to-exit signal unless the factory documentation identifies that function. Confirm controller timing, 24VDC power capacity, wire-transfer provision and free mechanical exit before finalizing the installation.
Selecting an Exit-Device-Specific Motorized Retraction Kit
MLRK1 is a family of motorized latch-retraction retrofits, not a single universal motor assembly. Each selectable SKU matches a specified exit-device manufacturer and series. Confirm the installed panic hardware’s exact model, version, length and rim / vertical-rod / mortise construction before using the compatibility selector. A different make or series can require another mounting interface and kit.
Electrical and Control-System Planning
- Power: Plan for the chosen kit’s 24VDC requirements and distinguish momentary motor retraction current from any holding current. Size the source, cabling and control contacts using the selected kit’s instructions.
- Operating modes: Define whether the door needs momentary authorized access, timed latch retraction or a sustained electric-dogging configuration permitted by the device. Confirm compatibility with the access-control sequence and egress design.
- REX signals: Request-to-exit monitoring is only present when explicitly supplied as part of a chosen configuration or separately installed accessory. The MLRK1-HAG-REX is distinct from the standard Hager kit.
- Exit device mechanics: Preserve the factory mechanical exit function, comply with the current exit-device listing and verify the modified assembly’s required fire-door and panic-hardware approvals.
Survey and Commissioning Checklist
- Record manufacturer, series, device length, hand, rail or rod system, strike and whether the current installation has dogging or monitoring.
- Match that information to the exact MLRK1 model and latest manufacturer installation sheet; verify required module, harness and mounting components.
- Confirm door/frame wiring path, power transfer, power supply and access-control relay requirements.
- After field installation, test authorized latch retraction, timed release, full relatching, free mechanical egress and normal operation on loss of electrical power.
Package scope: The chosen motor retrofit kit is not a complete exit device, power supply or access-control system. Review model-specific inclusions below for any module, switches, harness or other accessories.
Available Exit-Device Retrofit Variants
| Compatible exit device | Command Access SKU |
|---|---|
| Adams Rite 82/84/86/88/P88 Series | MLRK1-AR |
| Cal-Royal 98/2200 Series | MLRK1-CAL |
| Cal-Royal 7700 Series | MLRK1-CAL77 |
| Corbin Russwin 4000/5000 & Yale 7000 | MLRK1-COR |
| Dorma 9000 Series | MLRK1-DOR |
| Falcon 16/17 & First Choice 36/37 | MLRK1-FAL17 |
| Falcon 24/25 Series | MLRK1-FAL25 |
| Hager 4500/4600 Series | MLRK1-HAG |
| Jackson 1285/1295 & Kawneer 1686/1786 | MLRK1-JAC12 |
| Sargent 80 Series | MLRK1-SGT |
| Von Duprin 22 Series | MLRK1-VD22 |
| Von Duprin 33/35 & 98/99 Series | MLRK1-VD |
| Hager 4500 Series with REX | MLRK1-HAG-REX |
| Arrow 1000 Series | MLRK1-ARW |
| Detex Advantex & Value Series | MLRK1-DTX |
| PDQ 6200 Series | MLRK1-PDQ |
How to Select and Install an MLRK1 Kit
- Identify the host device: Check exact manufacturer, panic-device series, rim versus vertical-rod versus mortise configuration, device length and the latest approved Command Access compatibility guide.
- Understand the function: Electrical power retracts the latch for a controlled-access or push/pull operating mode; removing the electric command restores normal mechanical latching, subject to proper installation and adjustment.
- Power engineering: Use a regulated 24VDC power source sized for the selected model's peak retraction current and holding current. Evaluate start-up load, wire gauge, wiring distance and voltage drop rather than relying on nominal voltage alone.
- Controller and setup: Supplied motor modules, Push-to-Set adjustments, connector details and required field components can differ by kit. Follow the exact model insert, not another MLRK1 variant's instructions.
- REX selection: The variant with the REX suffix expressly includes request-to-exit monitoring. For other versions, check whether optional REX monitoring is available and ordered separately.
- Safety and verification: Test latch retraction, full latch return, manual panic exit, supply interruption and any fire-rated or delayed-egress requirements applicable to the complete door.
Kit scope: Retrofit kit and designated factory components for the selected exit-device family; the existing exit device, external supply, access controller, special power-transfer hardware and installer labor are not automatically included.
Before You Order
- Match the exact factory model and variant to the project hardware schedule; model suffixes indicate important operational differences.
- Confirm electrical supply, wiring, control interface, local codes and compatibility with the installed equipment.
- Use current manufacturer wiring diagrams, cut sheets and installation instructions; test the complete door assembly after installation.
Command Access Technologies MLRK1 Series Motorized Latch Retraction Kits convert compatible mechanical commercial exit devices into electronically controlled latch-retraction systems. Choose the compatible exit-device manufacturer and series in the variant selector. Each option is a distinct, manufacturer-specific 24VDC motorized retrofit kit for the listed panic device—these kits are not universally interchangeable.
Key Features & Benefits
- Motorized latch retraction: Electrically retracts the exit device latch and actuates the pushpad so compatible openings can support controlled entry, electric dogging and specified push/pull applications.
- Designed for retrofit: Field-installable kit options for many popular brands of existing mechanical panic and fire-exit hardware, subject to the compatible device's configuration and listing.
- 24VDC power: MLRK1 motorized kits use nominal 24V DC. Supply regulated power within the specific model's published voltage limits using appropriate wiring and access-control equipment.
- Fail-secure / EU latch-retraction principle: On power interruption, the electric latch-retraction function releases and the mechanical device returns to its normal latching operation. Mechanical egress must remain free through the exit device.
- Motor-driven MM-series control: Manufacturer smart modules provide diagnostics and post-installation latch calibration; control module generation and electrical requirements may vary with the selected retrofit kit.
- Push-to-Set (PTS) adjustment: Electronic adjustment assists with setting latch-retraction travel after installation, reducing mechanical adjustment time.
- Continuous-duty electric dogging: When the compatible exit device is held retracted for approved applications, the kit can support push/pull passage without requiring a manually dogged pushpad.
- REX availability varies: Request-to-exit (REX) monitoring is included on certain manufacturer-specified kits and is an optional factory/field accessory on others. A separate built-in REX upgrade is not included automatically with every standard option.
- Commercial duty: Suitable for correctly specified offices, hospitals, educational facilities, institutional buildings, airports and high-traffic facilities requiring secure access control.
Select the Correct Compatible Variant
Choose the exact kit for your installed exit-device brand and series. The selected Shopify variant determines the manufacturer SKU and compatibility.
| Compatible exit device | Manufacturer part number |
|---|---|
| Adams Rite 82/84/86/88/P88 Series | MLRK1-AR |
| Adams Rite EX Series | MLRK1-AREX |
| Arrow 1000 Series | MLRK1-ARW |
| Cal-Royal 98/2200 Series | MLRK1-CAL |
| Cal-Royal 7700 Series | MLRK1-CAL77 |
| Corbin Russwin 4000/5000 & Yale 7000 | MLRK1-COR |
| Dexter 1000 Series | MLRK1-DEX |
| Dorex 9500 Series | MLRK1-DRX |
| Dorma 9000 Series | MLRK1-DOR |
| Detex Advantex & Value Series | MLRK1-DTX |
| Falcon 16/17 & First Choice 36/37 | MLRK1-FAL17 |
| Falcon 24/25 Series | MLRK1-FAL25 |
| Hager 4500/4600 Series | MLRK1-HAG |
| Jackson 1285/1295 & Kawneer 1686/1786 | MLRK1-JAC12 |
| Marshall Best Q1/2000 Series | MLRK1-MBS |
| Marks M9900 & Design Hardware 1000 | MLRK1-MRK |
| Marks M8800 Series | MLRK1-MRK8 |
| PDQ 6200 Series | MLRK1-PDQ |
| PDQ 63/6400 Series | MLRK1-PDQ63 |
| Philadelphia Hardware 9000 | MLRK1-PHI |
| Sargent 80 Series | MLRK1-SGT |
| Stanley QED 100/200 | MLRK1-SQ |
| Tell 9500 Series | MLRK1-TEL |
| Townsteel 1000 Series | MLRK1-TS1 |
| Townsteel 9700 Series | MLRK1-TS2 |
| Von Duprin 22 Series | MLRK1-VD22 |
| Von Duprin 33/35 & 98/99 Series | MLRK1-VD |
| Von Duprin 33/35 & 98/99 AX Series | MLRK1-VDAX |
Technical Information
| Manufacturer | Command Access Technologies |
|---|---|
| Product Family | MLRK1 Motorized Latch Retraction Retrofit Kits |
| Purpose | Field conversion of compatible mechanical exit devices to electronically powered latch retraction |
| Nominal Voltage | 24VDC (model-specific acceptable range and wiring requirements apply) |
| Electrical Control | Motorized latch-retraction module, compatible access-control power supply and wiring required |
| Typical Exit Device Styles | Rim, surface vertical rod, concealed vertical rod and mortise exit devices, where the specific kit supports that device |
| Fail-Secure Function | EU-style motorized latch retraction; exit hardware mechanically latches when electric retraction is removed |
| Field Adjustment | PTS electronic latch-travel calibration on applicable kits |
| Request-to-Exit | Model-dependent: may be built-in, factory-optional or field-installable; verify particular variant |
| Electrical Ratings | Peak and holding current vary by exact model and control module; follow the individual factory instruction sheet |
| Warranty | Manufacturer three-year limited warranty; current factory conditions apply |
Where These Kits Are Used
Commercial doors with existing mechanical panic bars, storefront and institutional exit devices, controlled public entrances, automatic-door integrations, warehouse doors and other applications where authorized electronic latch retraction is specified. Match each model to the actual exit-device series and mounting configuration.
Installation & Compatibility Checklist
- Identify the exit device by manufacturer, model series, device type (rim/SVR/CVR/mortise), length and existing electrification before selecting a variant.
- Confirm the chosen MLRK1 kit and existing device are compatible with the current Command Access instructions, fire-rating/listing restrictions and factory approved conversions.
- Use a regulated, appropriately sized 24VDC Class 2 power source and wiring capable of supporting the selected kit's startup/peak current.
- Follow manufacturer instructions for motor mounting, mechanical connections, exit-device cover clearance, pushpad travel and electronic PTS calibration.
- Verify whether a built-in REX switch is required and included; specify a compatible separate REX kit or enhanced model if needed.
- Test motor retraction, normal latch restoration after power removal, continuous-duty dogging if applicable, manual emergency egress and coordination with the access-control or automatic-door system.
- Check applicable fire-door, accessibility and egress rules before modifying exit hardware. Use a qualified installer where required.
Package Scope
Included: One Command Access MLRK1 motorized latch retraction retrofit kit for the selected variant, consisting of the factory-specified motor/control assembly and model-specific retrofit accessories. Exact mounting hardware, connectors, REX equipment and wiring components vary by model; consult each manufacturer's packing list.
Not assumed included: Complete exit device/panic bar, separate power supply, door controller, credential reader, extra monitoring kit, door loop or power-transfer hardware. Select one compatible kit per exit device.
Additional compatible exit-device retrofit kit options
Select the exact MLRK1 kit matching your exit device. Request-to-exit (REX) is included only with expressly designated REX kits. Not all retrofit configurations use identical mounting hardware or control electronics.
Hager 4500 Series with REX — MLRK1-HAG-REX
Upgrade an approved Hager commercial exit device for electronic access control with the Command Access Technologies MLRK1-HAG-REX Motorized Latch Retraction Kit. Designed for the Hager 4500 Series exit-device platform, this 24VDC motorized retrofit kit includes request-to-exit (REX) monitoring for applications that require an electrical indication when the exit device is operated from inside. The MLRK1 smart-module design electronically retracts the latch for authorized access while preserving normal mechanical pushpad egress when installed correctly.
Features and Benefits
- Hager exit-device retrofit: Manufacturer-specific MLRK1-HAG hardware fits approved Hager 4500/4600-series applications. Verify the precise model, rim or vertical-rod configuration, and the current factory compatibility matrix.
- Built-in REX monitoring: The -REX configuration includes a request-to-exit switch for reporting interior exit-device actuation to a compatible controller or monitoring input; this is not merely the standard kit with an unsupported REX claim.
- Motorized latch retraction: Provides electrical pullback of the exit-device latch/pushpad for authorized entry, controlled release, or approved electric dogging scenarios.
- 24VDC operation: Designed for a regulated 24VDC access-control supply; the published input tolerance is 24VDC ±10%.
- Smart-module diagnostics: Factory MLRK1-HAG installation literature identifies an MM5 module with audible diagnostic feedback and simplified field setup.
- Push-to-Set (PTS) calibration: One-touch latch-retraction adjustment helps match motor travel to the actual exit-device installation.
- Continuous-duty electrical dogging: Motorized latch hold and automatic re-engagement support compatible installations with electrically dogged openings where permitted.
- Built for commercial facilities: Useful for controlled office entrances, educational and institutional buildings, healthcare administration, retail storefronts and security-system retrofits.
- Three-year manufacturer warranty: Manufacturer publishes a three-year limited warranty for its compatible MLRK1 exit-device kit family; consult current written warranty terms.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer SKU | MLRK1-HAG-REX |
| Product Family | MLRK1 Motorized Latch Retraction Retrofit Kit |
| Primary Compatibility | Hager 4500 Series commercial exit devices; 45/4600 family as specified by the manufacturer |
| Mechanism | Motor-driven latch and pushpad retraction |
| Power Input | 24VDC ±10%, per current manufacturer insert |
| Average Latch-Retraction Current | Approximately 900 mA, per published HAG-family installation instructions |
| Average Holding Current | Approximately 215 mA, per published HAG-family installation instructions |
| Control Module | Manufacturer MLRK smart module; MM5 identified in HAG-family instructions |
| Adjustment | PTS (Push-to-Set) electronic latch-travel calibration |
| Request-to-Exit (REX) | Included as specified by -REX factory configuration |
| REX Contact Type | SPDT monitoring contact; manufacturer insert identifies 0.5A at 24V contact rating |
| REX Wires | Green = common; blue = normally open; gray = normally closed, per published insert |
| Minimum Supply Wiring | 18 AWG; follow voltage-drop limitations and the exact supplied wiring instructions |
| Power Supply | Appropriately sized, filtered/regulated, power-limited Class 2 DC supply |
| Electric Dogging | Continuous-duty on compatible approved exit-device applications |
| Unit Weight | Approximately 2 lb according to reseller listing; packaged shipping weight varies |
| Warranty | Manufacturer three-year limited warranty; current terms apply |
REX vs. Standard Latch Retraction
The MLRK1-HAG-REX includes request-to-exit monitoring for applications where a building's access-control or security panel needs to detect operation of the exit device. The separately designated MLRK1-HAG is the standard non-REX configuration unless its exact manufacturer order code states otherwise. REX is a monitoring contact, not a stand-alone access controller, door-position sensor or remote push button.
Compatible Exit-Device Selection
This listing is specified for Hager 4500 Series exit hardware. The underlying Command Access HAG-family design is also discussed in manufacturer literature for compatible IDC 8000, PDQ 6200, Stanley QED, LSDA 9000 and Lawrence 8000 series devices, but these may use different orderable kit SKUs. Do not assume this HAG-REX SKU substitutes for those models without written manufacturer confirmation.
Installation Checklist
- Confirm the installed panic device is a compatible Hager 4500/4600 family exit device and identify its rim/vertical-rod type, length, existing electrical options, fire-rating and opening requirements.
- Provide a 24VDC ±10% power-limited Class 2 supply appropriately rated for motor startup/retraction and holding current. Confirm device placement and voltage drop with the manufacturer installation sheet.
- Route power through approved door transfer equipment and observe the manufacturer's instruction for direct power-supply-to-module wiring, without prohibited in-line relay/controller devices.
- Install the motor mount, spacer, adjustment and fasteners supplied for the applicable Hager device; verify pushpad clearance and compatible filler plates.
- Complete the PTS calibration and verify full latch retraction, reliable relatching on removal of power and normal manual panic egress.
- Connect the included SPDT REX contact to the appropriate low-voltage monitoring input and verify the common, normally-open and normally-closed signals against the supplied wiring guide.
- Check electric-dogging behavior, access-control coordination, door hardware listings and applicable fire, accessibility and life-safety codes before returning the opening to service.
Package Contents and Exclusions
Product: One factory-configured Command Access MLRK1-HAG-REX motorized latch-retraction retrofit kit with REX capability, motor/control assembly and model-specific installation components. Published HAG-family documentation lists a motor mount with smart module, Molex pigtail, mounting screws and spacer; the actual REX switch, leads and accessory contents should be checked against the shipped kit revision.
Not included: The complete Hager panic device, independent power supply, external access controller or reader, electric hinge or door loop, door/frame and any unrelated monitoring accessory. This is a motorized retrofit kit, not a complete exit device.
Arrow 1000 Series — MLRK1-ARW
Upgrade approved Arrow commercial panic hardware for electronic access control with the Command Access Technologies MLRK1-ARW Motorized Latch Retraction Kit. This field-installable 24VDC motorized latch-retraction retrofit is specifically documented by the manufacturer for compatible Arrow 1000 Series exit devices. It electrically retracts the latch and pushpad to support controlled entry, appropriate electric dogging and approved door-operator integrations while allowing the exit device to retain its normal mechanical egress function when correctly installed.
Compatibility note: The distributor describes this kit for Arrow 1000, 2000 and 3000 Series; current Command Access product and installation literature explicitly identify the Arrow 1000 Series. For Arrow 2000/3000 hardware, confirm exact model and installation compatibility with Command Access before ordering. This kit is not a universal retrofit and is not a complete exit device.
Key Features and Benefits
- Arrow exit-device retrofit: Engineered for the Arrow 1000 Series platform using a manufacturer-specific mounting and drive arrangement. Confirm installed panic device series, condition and hardware configuration.
- Electric latch retraction: A powered motor moves the exit device's latch/pushpad mechanism to facilitate authorized entry where the full door system is correctly designed.
- 24VDC power input: Operates at nominal 24VDC ±10% in accordance with Command Access MLRK1-ARW installation literature.
- Remote MM4S module: Factory literature for this kit identifies an MM4S remote motor-control module, associated motor mounting assembly and cable harness. Do not assume an MM5 module is included.
- Low- and high-torque modes: Manufacturer documentation lists average latch-retraction currents of 900mA (low torque) and up to 2A (high torque), depending on setup and hardware resistance.
- Efficient holding operation: Published holding currents are approximately 215mA in low-torque mode and 250mA in high-torque mode. Size the supply for the higher retraction current as well as hold current.
- Electric dogging capability: Where the exit-device application and its listings permit, powered latch retraction can hold the pushpad retracted for scheduled push/pull access.
- Mechanical free egress: The interior panic device must remain operable for normal emergency exit independent of access-control authorization.
- Field-installable kit: Retrofitting a compatible existing mechanical exit device may avoid replacement of the complete panic bar.
- REX monitoring optional: A compatible request-to-exit switch can be specified separately where available. This standard MLRK1-ARW part number does not imply built-in REX monitoring.
- UL-listed product family: Command Access advertises a UL-listed retrofit kit with a three-year manufacturer warranty; confirm the appropriate device and full-opening listing before modification.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer Part Number | MLRK1-ARW |
| Product Family | MLRK1 Motorized Latch Retraction Retrofit Kits |
| Primary Verified Compatibility | Arrow 1000 Series exit devices; other Arrow models require confirmation |
| Supplier's Additional Compatibility Description | Arrow 1000, 2000 and 3000 Series — verify 2000/3000 models with manufacturer |
| Latch-Retraction Mechanism | Motor-driven retrofit for existing compatible exit device |
| Power Input | 24VDC ±10% |
| Average Low-Torque Latch Retraction Current | 900mA |
| Average High-Torque Latch Retraction Current | 2A |
| Average Low-Torque Holding Current | 215mA |
| Average High-Torque Holding Current | 250mA |
| Control Module | Remote MM4S motor-control module, per published kit insert |
| Minimum Wiring Gauge | 18 AWG; verify distance and voltage drop |
| Recommended Supply | Power-limited Class 2 DC supply; regulated and filtered per manufacturer requirements |
| Supply-to-Module Connection | Direct power run; factory instructions prohibit relays or access-control units placed between the supply and motor module |
| Built-In Request-to-Exit | Not included in standard MLRK1-ARW SKU |
| Warranty | Three-year limited manufacturer warranty, subject to factory terms |
| Shipping Weight | 4 lb estimated packaged shipping weight; verify before dispatch |
Arrow Series Compatibility
The MLRK1-ARW is the dedicated Command Access motorized retrofit for compatible Arrow 1000 Series exit devices. The supplier catalog also refers to Arrow 2000 and 3000 Series; these additional series should be checked individually with Command Access before a retrofit is selected. Confirm the exact device model, style (rim, mortise or vertical rod as applicable), length, fire-rating, existing electric modifications and mechanical condition. Do not substitute MLRK1-AR, which is an Adams Rite motor kit, for the Arrow-specific MLRK1-ARW.
Power and Wiring Notes
The factory insert specifies 24VDC ±10% with at least 18 AWG supply conductors. Select a compatible power-limited Class 2 supply capable of supporting the motor's potential 2A high-torque retraction current when required by the application, in addition to steady holding current. The manufacturer instructs installers to run power directly from the supply to the motor module; install controls only through the permitted factory interface rather than putting an incompatible relay in series with the module's supply path. Follow the specific MM4S wiring and installation guide.
Installation and Commissioning Checklist
- Verify hardware: Confirm the installed exit device is an approved Arrow 1000 Series unit; ask the manufacturer to confirm compatibility for any Arrow 2000 or 3000 model.
- Review the installation insert: Check the required tools, manufacturer-specific motor mounting position, pushpad adjustment, door clearances, and the current parts list before disassembly.
- Prepare the opening: Protect door finishes and provide the correct transfer wiring pathway, appropriately sized power supply and controller interface for the intended access-control function.
- Fit the motor kit: Install the motor mount and remote MM4S module, route the factory connectors and cables, and ensure the pushpad and linkage move without binding.
- Configure motor operation: Set the correct low/high torque behavior in accordance with factory instructions and observe actual current draw and latch travel.
- Verify retraction and relatching: Test powered latch retraction, release on power removal, mechanical pushpad travel, dogging behavior where approved and emergency exit operation.
- Check system integration: Test credential entry or door-operator coordination and any separately installed REX or position monitoring accessories.
- Confirm required compliance: Verify fire-door listings, egress, accessibility and the complete opening's approved hardware schedule after the retrofit is complete.
Published Kit Components
The manufacturer MLRK1-ARW/MM4S insert describes a motor mount, Phillips-head mounting screw, Molex pigtail, two cable ties, mounting pads, remote MM4S module and a remote-module cable. Other insert revisions identify different connector and power-lead arrangements. Confirm the supplied revision and included hardware against the current kit packing list.
Applications
Commercial offices, institutional buildings, schools, healthcare facilities, retail stores, managed-access corridors and other facilities that use compatible Arrow exit hardware and need electronic latch retraction for secure, controlled access.
Not Included
The Arrow exit device itself, door/frame, separate access-control reader, power supply, door power-transfer hinge or loop, automatic door operator and separate request-to-exit monitoring accessories are not included unless specified in the manufacturer's kit contents. This listing is for one MLRK1-ARW motorized retrofit kit, not a complete door-hardware assembly.
Detex Advantex & Value Series — MLRK1-DTX
The Command Access Technologies MLRK1-DTX Motorized Latch Retraction Kit converts compatible Detex Advantex and Detex Value Series exit devices to electronically controlled latch retraction. This field-installable 24VDC retrofit kit uses the Command Access motorized pullback assembly and one-touch Push-to-Set (PTS) adjustment for commercial doors requiring controlled entry, electric dogging, and dependable mechanical exit operation. The MLRK1-DTX is designed specifically for the listed Detex platforms and is not a universal latch retraction kit or a complete panic bar.
Key Features and Benefits
- Designed for Detex exit devices: Factory retrofit kit for properly matched Detex Advantex and Value Series mechanical exit devices, subject to the device type, condition, and factory installation instructions.
- Motor-driven latch retraction: Electrically retracts the compatible pushpad and latch assembly, enabling authorized access or an approved electric dogging application while preserving mechanical panic egress.
- 24VDC electrical operation: Nominal 24VDC ±10%. This is not a 12V kit; size and wire the approved power supply for the published draw.
- New-generation MM5 smart module: Integrated diagnostics and audible feedback assist with power checks, adjustments and troubleshooting.
- One-touch Push-to-Set: PTS adjustment helps set optimal latch travel after installation to accommodate the actual exit device.
- Continuous-duty electric dogging: Suitable for manufacturer-approved electric latch-hold/retracted operation, with automatic re-engagement where specified by the exit-device configuration.
- Fire-rated device hardware: Manufacturer kit includes a dogging L bracket, screws, and washers for the relevant approved fire-device installation steps; verify the complete opening's labeling and compliance.
- Value and Advantex filler plates: Separate dogging-hole plugs are supplied for the two Detex platform types; Value Series plastic filler plates may require the precise factory-prescribed clearance modification.
- Request-to-exit optional: REX monitoring can be added with a model-specific factory or field option but is not included with this standard SKU. The REX-equipped model is separately identified.
- Commercial retrofit: Applicable to authorized access, selected push/pull openings, and automatic-operator integrations where the complete system is specified appropriately.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer SKU | MLRK1-DTX |
| Product Family | MLRK1 Motorized Latch Retraction |
| Compatibility | Compatible Detex Advantex and Detex Value Series exit devices |
| Mechanism | Motorized exit-device pushpad and latch retraction retrofit |
| Voltage | 24VDC ±10% |
| Average Latch-Retraction Current | 900 mA, per manufacturer insert instructions |
| Average Holding Current | 215 mA, per manufacturer insert instructions |
| Recommended Wiring | 18 AWG minimum, power supply to module direct wiring as specified by manufacturer |
| Power Supply | Power-limited Class 2; follow the Command Access factory recommendations |
| PTS Calibration | One-touch post-installation Push-to-Set adjustment |
| Control Module | MM5 smart module per published MLRK1-DTX instructions |
| REX Switch | Optional, not included in this base SKU |
| Unit Weight | Approximately 3 lb per manufacturer product sheet; shipping weight may vary |
| Manufacturer Warranty | Three-year limited manufacturer warranty; confirm current terms |
Typical Applications
Commercial, institutional, educational, healthcare and facility doors equipped with compatible Detex Advantex or Value Series panic and exit devices, where properly designed electronic latch retraction can coordinate with an access-control reader, scheduled access, push/pull operation, or an automatic door operator.
Installation and Selection Checklist
- Confirm the installed device is a supported Detex Advantex or Detex Value Series model. Identify the exit-device type and length, any vertical-rod configuration and existing factory electrification before ordering.
- Use a regulated and filtered 24VDC power supply that meets the manufacturer's Class 2 requirement and supports the kit's latch-retraction and holding current.
- Follow the current factory insert and wiring instructions. A direct wire run from the power supply to the module is specified; do not place a relay or access controller in-line between supply and the motor module where the manufacturer prohibits it.
- Install the motor assembly and provided dogging L bracket and set screws per manufacturer directions. Select the appropriate Detex platform dogging-hole plug.
- On Value Series plastic filler plates, perform only the manufacturer's specified motor-clearance modification. The published Advantex metal-plate installation follows a different procedure.
- Set the pushpad travel using the PTS procedure, confirm latch retraction and restoration, and test the smart-module diagnostics.
- Verify all manual panic egress, latch engagement, fire-door restrictions, electrical access control and automatic-operator interactions against the door hardware schedule and applicable codes.
Kit Components
The manufacturer identifies an MLRK1-DTX motor assembly (60747), Molex pigtail (50944), 3/32-inch hex key (10017), four 10-32 x 1/4-inch set screws (41103), Value Series dogging-hole plug (40144), Advantex Series dogging-hole plug (41199), dogging L bracket (53023), two 10-24 x 1/4-inch pan-head screws (41196), and two #10 lock washers (41197). Check actual factory packing contents and product revisions upon receipt.
Not Included
The Detex exit device or panic bar, separate power supply, reader, access controller, power transfer, door or frame, and optional REX monitoring kit are not included unless specified separately. This listing is for one MLRK1-DTX standard motorized retrofit kit.
PDQ 6200 Series — MLRK1-PDQ
The Command Access Technologies MLRK1-PDQ Motorized Latch Retraction Kit is a field-installable electrification upgrade for compatible PDQ 6200 Series commercial exit devices. The kit converts an existing mechanical exit device to 24VDC motor-driven latch and pushpad retraction, helping commercial facilities integrate credential-controlled entry, authorized latch release, and approved continuous-duty electric dogging without replacing the complete panic device.
Designed for the PDQ 6200 platform, the Command Access retrofit features an MM5 smart control module, built-in diagnostic feedback, and electronic Push-to-Set (PTS) adjustment. It is a hardware-specific kit rather than a universal motor or complete panic bar. Always verify the installed device type, required clearance, and current factory retrofit compatibility before ordering.
Key Features & Benefits
- PDQ 6200 Series compatibility: The MLRK1-PDQ is the Command Access-designated kit for compatible PDQ 6200 Series exit devices. PDQ 63/6400 Series hardware requires a different kit, MLRK1-PDQ63.
- Motorized latch retraction: Electrically retracts the pushpad/latch mechanism to support controlled entry and approved electric dogging applications.
- 24VDC input: The manufacturer specifies 24VDC ±10% for the applicable MLRK1-HAG/PDQ retrofit family.
- MM5 smart module: Provides onboard diagnostic functions and audible feedback to simplify troubleshooting and post-installation setup.
- Electronic Push-to-Set calibration: PTS adjustment helps set the amount of latch/pushpad retraction electronically after installation.
- Low-current holding design: Manufacturer's instruction sheet lists average draw of 900mA during retraction and 215mA while holding. Power supply and wire sizing must accommodate the operating requirements.
- Continuous-duty electric dogging: On compatible, approved openings, the motorized kit can hold the latch retracted while energized, allowing push/pull passage; the device relatches when retraction power is removed.
- Mechanical emergency egress: The existing exit device's normal pushpad function must remain operable for emergency exiting when installed correctly.
- Optional request-to-exit monitoring: The manufacturer's kit family supports a separate REX option; built-in REX is not assumed included in this base MLRK1-PDQ SKU.
- Commercial-duty upgrade: Suitable for appropriately specified access-controlled doors in offices, schools, healthcare facilities, retail buildings, and institutional environments.
Technical Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Part Number | MLRK1-PDQ |
| Product Category | Field-installable motorized latch retraction retrofit kit |
| Compatible Exit-Device Family | PDQ 6200 Series |
| Mechanism | Motor-driven pushpad and latch retraction |
| Nominal Input Voltage | 24VDC ±10% |
| Average Latch-Retraction Current | 900mA per published Command Access family instructions |
| Average Holding Current | 215mA per published Command Access family instructions |
| Minimum Recommended Wire Gauge | 18 AWG per manufacturer instructions |
| Power Source | Power-limited Class 2; appropriately filtered and regulated 24VDC supply |
| Control Module | MM5 smart motor module |
| Adjustment | Push-to-Set electronic latch travel calibration |
| Electric Dogging | Continuous-duty capability on approved compatible devices |
| REX Monitoring | Optional; not included unless separately ordered or confirmed |
| Warranty | Published three-year limited manufacturer warranty; verify current conditions |
| Shipping Weight | 4 lb estimated packaged weight; verify carton weight before shipping |
Compatibility and Kit Selection
Select MLRK1-PDQ for a compatible PDQ 6200 Series exit device. Do not substitute the MLRK1-PDQ63 used for PDQ 63/6400 Series devices. Because the MLRK1-HAG installation family also covers Hager, IDC, Stanley QED, Lawrence and LSDA models, other brands may require a different orderable manufacturer SKU even when certain installation instructions are shared. For PDQ 6200 devices, confirm the exact panic or fire-exit configuration, manufacturer-approved conversion, device length, and remaining filler-plate length using the current installation documents.
Electrical Design and Wiring Notes
The manufacturer specifies a regulated 24VDC ±10% supply and minimum 18 AWG conductors. Its instructions call for a direct wiring run between the power supply and MLRK module rather than inserting a relay or access controller between them where prohibited. Interface the access-control signal with the manufacturer-approved power/control arrangement. Use a supply rated for motor startup and holding current, and account for voltage drop, wire length, and the overall opening's power requirements.
Manufacturer documentation for the MLRK1-HAG/PDQ family identifies a motor mount with MM5 module, Molex pigtail, two M4 × 6mm Phillips mounting screws, and a spacer. Confirm supplied accessories against the exact kit and revision. Installation may require pushpad/filler-plate adjustment depending on the exit device and device length.
Installation Checklist
- Identify the installed exit device: Confirm the device is an approved PDQ 6200 Series model and determine its type, handing, device length, hardware prep, fire-rating, and existing electrical options.
- Confirm compatibility: Compare the opening to the current Command Access MLRK1-PDQ/HAG factory instructions and the specific PDQ hardware configuration. Do not assume every PDQ device is interchangeable.
- Prepare a suitable power source: Supply appropriately regulated and filtered 24VDC from a power-limited Class 2 supply and run manufacturer-specified wiring with acceptable voltage drop.
- Install the retrofit: Mount the motor assembly and connecting components using the applicable template, correct bracket and included hardware, leaving adequate clearance for the pushpad and filler plate.
- Set latch travel: Perform the PTS calibration using the published MM5 instructions and confirm full latch retraction without mechanical binding.
- Verify access-control functions: Test an authorized unlock/latch retraction, continuous electric dogging if applicable, and restoration of normal latching when power is removed.
- Preserve safe exit: Confirm the mechanical pushpad still operates correctly at all times and that the finished installation meets applicable fire-door, emergency-egress, accessibility, and device-listing requirements.
Commercial Applications
Commercial offices, healthcare facilities, educational campuses, institutional buildings, warehouse administration areas, and other access-controlled openings with compatible PDQ 6200 Series mechanical exit devices. Appropriate configurations may coordinate with an access-control reader, building schedules, push/pull operating modes, or a low-energy automatic door operator.
What Is Included
Product: One Command Access MLRK1-PDQ motorized latch-retraction retrofit kit for a compatible PDQ 6200 Series exit device. Published family instructions identify the motor/MM5 assembly, wiring pigtail and mounting hardware; verify exact shipped contents and revisions.
Not Included
The complete PDQ panic/exit device, access-control reader or controller, separate 24VDC power supply, electrified hinge or door loop, automatic door operator, unrelated latch-monitoring accessories, and optional REX kit are not assumed included. This product is a motorized latch retraction retrofit kit only.