- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Command Access PS210 24VDC Linear Power Supply | 1.5A Continuous, 2.5A Boost
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Command Access PS210 24VDC Linear Power Supply | 1.5A Continuous, 2.5A Boost
Command Access PS210 24VDC Linear Power Supply | 1.5A Continuous, 2.5A Boost
$340.99
$238.69
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
The Command Access Technologies PS210 Linear Power Supply is a regulated 24VDC access-control power supply for compatible electrified commercial door hardware. Designed for applications such as electric latch-retraction exit devices, electrified locksets, electric strikes, and magnetic locks, it delivers 1.5 amps continuous at 24VDC with a 2.5-amp boost capability for short-duration inrush requirements. The PS210 uses a single solid-state input/output channel and is housed in a compact metal enclosure for professional low-voltage security installations.
Power Supply Sizing for Commercial Door Hardware
The PS210 provides a 24VDC regulated source rated for 1.5A continuous operation, with a separate 2.5A short-duration boost capability. The boost rating is not the maximum continuous load rating. Match the connected latch-retraction solenoid, electrified lock, strike or control equipment to the manufacturer’s requirements before selecting this model.
Installation Checklist
- Load calculation: Confirm total steady-state current and simultaneous energization, including inrush demands, wire-run voltage drop and the rating of any external relay or controller.
- Control interfaces: Use the manufacturer’s current wiring diagram for solid-state input/output connections and any specified alarm or release interface.
- Physical mounting: Confirm enclosure mounting, AC feed, field wiring separation, environmental requirements, service clearance and required branch protection.
- Final test: Verify regulated 24VDC under load and check that each connected device actuates and returns to its safe specified state.
Supplied scope: PS210 power supply assembly; access controller, locking hardware, field wiring, door-to-frame transfer and optional backup equipment are separate unless expressly included.
Important compatibility note: The manufacturer describes the PS210 as supporting up to two suitable electric latch-pullback or lock devices through one output, provided that simultaneous startup current, holding load, conductor size, wiring distance, and duty cycle remain within its published capacity. One input/output does not mean two independently controlled outputs. Verify the exact connected hardware's requirements and Command Access power-supply compatibility matrix before specifying a system.
Key Features and Benefits
- Regulated 24VDC power: Supplies 24 volts DC for properly rated low-voltage electrified locking components, subject to factory tolerance and circuit loading.
- 1.5A continuous output: Designed for continuous operation within its rated 1.5-amp output capacity.
- 2.5A short-duration boost: Provides temporary inrush support for select motorized or solenoid-driven exit devices when operated within manufacturer duty-cycle limits.
- Single solid-state input/output: One independently triggered control channel with a corresponding regulated and protected 24VDC output.
- Resettable output protection: One 1.5A auto-resetting, PTC-protected output helps limit damage caused by shorts and overload conditions.
- Regulated linear design: Designed to deliver stable low-voltage DC and accommodate the high inrush/hold characteristics of compatible electrical latch-retraction equipment.
- 120VAC input: Designed for 110-120VAC mains power, 60Hz, with a manufacturer-specified 2A input fuse rated at 250VAC.
- Diagnostic status indicators: Red AC-power LED and green DC-output/channel LED assist installers and service technicians.
- Removable wiring connectors: Euro-style terminal connectors simplify service and electrical terminations.
- Overvoltage and output protection: Includes circuit protection and an adjustable output-voltage trim control, per factory instructions.
- Fire-alarm integration: Manufacturer wiring instructions describe a fire-alarm link/tie-in using the unit's input. Plan and test disconnect behavior according to the local code and the current installation guide.
- Commercial metal enclosure: Metal housing measures 11 inches wide x 11 inches high x 4 inches deep with 1/2-inch and 3/4-inch knockouts.
- Removable cover: Hingeless, removable enclosure cover. Cam lock not included; confirm any security-locking hardware needed for the installation.
- UL 294 6th Edition: Manufacturer documentation identifies the PS210 as UL 294 Sixth Edition listed; verify any project-specific CSA and other requirements against current certificates.
- Made in USA: Manufacturer product literature identifies the PS210 power supply as built in the United States; confirm origin if a project requires formal domestic-origin documentation.
Product Specifications
| Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer Part Number / SKU | PS210 |
| Manufacturer Easy Order Number | 78850 |
| Category | Commercial access-control / electrified door hardware power supply |
| Design | Regulated linear DC power supply with short-duration boost |
| AC Input | 110-120VAC, nominal 120VAC, 60Hz |
| Input Fuse | 2A, 250VAC; use specified replacement only |
| Nominal DC Output | 24VDC, regulated |
| Continuous Output Current | 1.5 amperes |
| Boost Output | 2.5 amperes, short duration, subject to manufacturer duty cycle and load requirements |
| Inputs / Outputs | 1 solid-state input / 1 protected output |
| Trigger Input | Dry-contact control trigger; follow current Command Access instructions |
| Output Protection | 1 x auto-resetting 1.5A protected / PTC fused output |
| Output Voltage Adjust | Yes — manufacturer output trim control |
| Indicators | Red AC power; green DC output/channel |
| Fire Alarm Interface | Factory instructions describe a fire-alarm tie-in through the input; coordinate with system designer |
| Power Supply Enclosure | Metal; removable, hingeless cover; cam lock not included |
| Enclosure Dimensions | 11" W x 11" H x 4" D |
| Conduit Knockouts | 1/2" and 3/4" locations on enclosure sides |
| Operating Temperature | 32-120 degrees F (0-49 degrees C) |
| Maximum Humidity | 85 percent |
| Listed Standard | UL 294, 6th Edition, per manufacturer technical literature |
| Battery Back-Up | Not included with PS210 standard configuration |
| Manufacturer Product Weight | 10 lb |
| Manufacturer Shipment Weight | 11 lb |
| Shopify Shipping Weight | 11 lb per manufacturer shipment specification; reconfirm actual packed shipment as needed |
Typical Commercial Applications
- Electrified access-control mortise and cylindrical locks requiring a regulated 24VDC supply
- Compatible motor-driven latch-retraction exit devices and electric exit trim
- Compatible solenoid-driven commercial panic-device electrification hardware
- Electric strikes and magnetic locking devices within approved 24VDC current requirements
- Commercial office, institutional, healthcare, education and facility-access installations
- Replacement of a Command Access PS210 or professionally specified equivalent having one input/output and suitable electrical output ratings
PS210 versus Other Command Access Power Supplies
The PS210 has one solid-state input and one protected output for 1.5A continuous 24VDC operation and a brief boost capacity. Other Command Access models such as PS220/PS220B and PS440B offer different output counts, total amperage, and battery-backup options. Select the power supply according to the number of independently controlled doors, device inrush/hold current, expected simultaneous activity, battery-backup needs, and fire-alarm-interface design.
Installation and Ordering Checklist
- Confirm the exact model: Order PS210, not a board-only replacement or a different Command Access power supply.
- Review line power: Have qualified personnel provide the specified 110-120VAC, 60Hz branch-circuit power and observe electrical-safety procedures.
- Calculate connected hardware current: Verify the cumulative continuous, boost and simultaneous inrush loads for all connected hardware; ensure the protected output is not overloaded.
- Match control requirements: The PS210 has one solid-state input/output channel. Two devices may share a compatible output only when manufacturer conditions and the total load allow it; separate control requires another design.
- Confirm dry-contact trigger wiring: Follow the current factory installation diagram; do not apply voltage to an input intended for a dry contact.
- Check fire-alarm tie-in and egress: Coordinate any fire-alarm control, locking logic, life-safety requirements and egress code compliance with the applicable professionals.
- Protect field wiring and mount securely: Use the correct conduit knockouts, electrical grounding, wire gauges, separation and enclosure installation according to the manufacturer's instructions.
- Test the completed system: Verify red and green status LEDs, output voltage, lock or latch-retraction function, fire-alarm behavior when specified, and electrical performance during startup.
What's Included
One Command Access PS210 regulated linear 24VDC power supply in a metal enclosure with one solid-state input/output channel. Verify the manufacturer's supplied hardware and connector package for this order.
Not Included
Electrified door lock, electric strike, exit device, magnetic lock, access-control controller, independent power distribution board, backup battery, cam lock, door wiring, conduit or electrical installation labor. This listing is for the PS210 enclosed power supply only.