{"product_id":"command-access-ps210-24vdc-linear-power-supply-1-5a-continuous-2-5a-boost","title":"Command Access PS210 24VDC Linear Power Supply | 1.5A Continuous, 2.5A Boost","description":"\n\u003cp\u003eThe \u003cstrong\u003eCommand Access Technologies PS210 Linear Power Supply\u003c\/strong\u003e is a regulated \u003cstrong\u003e24VDC access-control power supply\u003c\/strong\u003e for compatible electrified commercial door hardware. Designed for applications such as electric latch-retraction exit devices, electrified locksets, electric strikes, and magnetic locks, it delivers \u003cstrong\u003e1.5 amps continuous at 24VDC\u003c\/strong\u003e with a \u003cstrong\u003e2.5-amp boost capability\u003c\/strong\u003e for short-duration inrush requirements. The PS210 uses a \u003cstrong\u003esingle solid-state input\/output channel\u003c\/strong\u003e and is housed in a compact metal enclosure for professional low-voltage security installations.\u003c\/p\u003e\u003ch3\u003ePower Supply Sizing for Commercial Door Hardware\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003ePS210\u003c\/strong\u003e provides a 24VDC regulated source rated for \u003cstrong\u003e1.5A continuous operation\u003c\/strong\u003e, with a separate \u003cstrong\u003e2.5A short-duration boost\u003c\/strong\u003e capability. The boost rating is not the maximum continuous load rating. Match the connected latch-retraction solenoid, electrified lock, strike or control equipment to the manufacturer’s requirements before selecting this model.\u003c\/p\u003e\u003ch4\u003eInstallation Checklist\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad calculation:\u003c\/strong\u003e Confirm total steady-state current and simultaneous energization, including inrush demands, wire-run voltage drop and the rating of any external relay or controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl interfaces:\u003c\/strong\u003e Use the manufacturer’s current wiring diagram for solid-state input\/output connections and any specified alarm or release interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical mounting:\u003c\/strong\u003e Confirm enclosure mounting, AC feed, field wiring separation, environmental requirements, service clearance and required branch protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal test:\u003c\/strong\u003e Verify regulated 24VDC under load and check that each connected device actuates and returns to its safe specified state.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupplied scope:\u003c\/strong\u003e PS210 power supply assembly; access controller, locking hardware, field wiring, door-to-frame transfer and optional backup equipment are separate unless expressly included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant compatibility note:\u003c\/strong\u003e The manufacturer describes the PS210 as supporting up to two suitable electric latch-pullback or lock devices through one output, provided that simultaneous startup current, holding load, conductor size, wiring distance, and duty cycle remain within its published capacity. \u003cstrong\u003eOne input\/output does not mean two independently controlled outputs.\u003c\/strong\u003e Verify the exact connected hardware's requirements and Command Access power-supply compatibility matrix before specifying a system.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulated 24VDC power:\u003c\/strong\u003e Supplies 24 volts DC for properly rated low-voltage electrified locking components, subject to factory tolerance and circuit loading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.5A continuous output:\u003c\/strong\u003e Designed for continuous operation within its rated 1.5-amp output capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5A short-duration boost:\u003c\/strong\u003e Provides temporary inrush support for select motorized or solenoid-driven exit devices when operated within manufacturer duty-cycle limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle solid-state input\/output:\u003c\/strong\u003e One independently triggered control channel with a corresponding regulated and protected 24VDC output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResettable output protection:\u003c\/strong\u003e One 1.5A auto-resetting, PTC-protected output helps limit damage caused by shorts and overload conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulated linear design:\u003c\/strong\u003e Designed to deliver stable low-voltage DC and accommodate the high inrush\/hold characteristics of compatible electrical latch-retraction equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120VAC input:\u003c\/strong\u003e Designed for 110-120VAC mains power, 60Hz, with a manufacturer-specified 2A input fuse rated at 250VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic status indicators:\u003c\/strong\u003e Red AC-power LED and green DC-output\/channel LED assist installers and service technicians.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable wiring connectors:\u003c\/strong\u003e Euro-style terminal connectors simplify service and electrical terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage and output protection:\u003c\/strong\u003e Includes circuit protection and an adjustable output-voltage trim control, per factory instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-alarm integration:\u003c\/strong\u003e Manufacturer wiring instructions describe a fire-alarm link\/tie-in using the unit's input. Plan and test disconnect behavior according to the local code and the current installation guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial metal enclosure:\u003c\/strong\u003e Metal housing measures \u003cstrong\u003e11 inches wide x 11 inches high x 4 inches deep\u003c\/strong\u003e with 1\/2-inch and 3\/4-inch knockouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable cover:\u003c\/strong\u003e Hingeless, removable enclosure cover. \u003cstrong\u003eCam lock not included\u003c\/strong\u003e; confirm any security-locking hardware needed for the installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 294 6th Edition:\u003c\/strong\u003e Manufacturer documentation identifies the PS210 as UL 294 Sixth Edition listed; verify any project-specific CSA and other requirements against current certificates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in USA:\u003c\/strong\u003e Manufacturer product literature identifies the PS210 power supply as built in the United States; confirm origin if a project requires formal domestic-origin documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCommand Access Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number \/ SKU\u003c\/th\u003e\n\u003ctd\u003ePS210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Easy Order Number\u003c\/th\u003e\n\u003ctd\u003e78850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eCommercial access-control \/ electrified door hardware power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRegulated linear DC power supply with short-duration boost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Input\u003c\/th\u003e\n\u003ctd\u003e110-120VAC, nominal 120VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Fuse\u003c\/th\u003e\n\u003ctd\u003e2A, 250VAC; use specified replacement only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal DC Output\u003c\/th\u003e\n\u003ctd\u003e24VDC, regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd\u003e1.5 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBoost Output\u003c\/th\u003e\n\u003ctd\u003e2.5 amperes, short duration, subject to manufacturer duty cycle and load requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs \/ Outputs\u003c\/th\u003e\n\u003ctd\u003e1 solid-state input \/ 1 protected output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrigger Input\u003c\/th\u003e\n\u003ctd\u003eDry-contact control trigger; follow current Command Access instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Protection\u003c\/th\u003e\n\u003ctd\u003e1 x auto-resetting 1.5A protected \/ PTC fused output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage Adjust\u003c\/th\u003e\n\u003ctd\u003eYes — manufacturer output trim control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicators\u003c\/th\u003e\n\u003ctd\u003eRed AC power; green DC output\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire Alarm Interface\u003c\/th\u003e\n\u003ctd\u003eFactory instructions describe a fire-alarm tie-in through the input; coordinate with system designer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply Enclosure\u003c\/th\u003e\n\u003ctd\u003eMetal; removable, hingeless cover; cam lock not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure Dimensions\u003c\/th\u003e\n\u003ctd\u003e11\" W x 11\" H x 4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConduit Knockouts\u003c\/th\u003e\n\u003ctd\u003e1\/2\" and 3\/4\" locations on enclosure sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e32-120 degrees F (0-49 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Humidity\u003c\/th\u003e\n\u003ctd\u003e85 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed Standard\u003c\/th\u003e\n\u003ctd\u003eUL 294, 6th Edition, per manufacturer technical literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Back-Up\u003c\/th\u003e\n\u003ctd\u003eNot included with PS210 standard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Product Weight\u003c\/th\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Shipment Weight\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e11 lb\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShopify Shipping Weight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e11 lb\u003c\/strong\u003e per manufacturer shipment specification; reconfirm actual packed shipment as needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Commercial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrified access-control mortise and cylindrical locks requiring a regulated 24VDC supply\u003c\/li\u003e\n\u003cli\u003eCompatible motor-driven latch-retraction exit devices and electric exit trim\u003c\/li\u003e\n\u003cli\u003eCompatible solenoid-driven commercial panic-device electrification hardware\u003c\/li\u003e\n\u003cli\u003eElectric strikes and magnetic locking devices within approved 24VDC current requirements\u003c\/li\u003e\n\u003cli\u003eCommercial office, institutional, healthcare, education and facility-access installations\u003c\/li\u003e\n\u003cli\u003eReplacement of a Command Access PS210 or professionally specified equivalent having one input\/output and suitable electrical output ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePS210 versus Other Command Access Power Supplies\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePS210\u003c\/strong\u003e has \u003cstrong\u003eone solid-state input and one protected output\u003c\/strong\u003e for \u003cstrong\u003e1.5A continuous 24VDC\u003c\/strong\u003e operation and a brief boost capacity. Other Command Access models such as PS220\/PS220B and PS440B offer different output counts, total amperage, and battery-backup options. Select the power supply according to the number of independently controlled doors, device inrush\/hold current, expected simultaneous activity, battery-backup needs, and fire-alarm-interface design.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Ordering Checklist\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the exact model:\u003c\/strong\u003e Order \u003cstrong\u003ePS210\u003c\/strong\u003e, not a board-only replacement or a different Command Access power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview line power:\u003c\/strong\u003e Have qualified personnel provide the specified \u003cstrong\u003e110-120VAC, 60Hz\u003c\/strong\u003e branch-circuit power and observe electrical-safety procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculate connected hardware current:\u003c\/strong\u003e Verify the cumulative continuous, boost and simultaneous inrush loads for all connected hardware; ensure the protected output is not overloaded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch control requirements:\u003c\/strong\u003e The PS210 has \u003cstrong\u003eone\u003c\/strong\u003e solid-state input\/output channel. Two devices may share a compatible output only when manufacturer conditions and the total load allow it; separate control requires another design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm dry-contact trigger wiring:\u003c\/strong\u003e Follow the current factory installation diagram; do not apply voltage to an input intended for a dry contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck fire-alarm tie-in and egress:\u003c\/strong\u003e Coordinate any fire-alarm control, locking logic, life-safety requirements and egress code compliance with the applicable professionals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect field wiring and mount securely:\u003c\/strong\u003e Use the correct conduit knockouts, electrical grounding, wire gauges, separation and enclosure installation according to the manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the completed system:\u003c\/strong\u003e Verify red and green status LEDs, output voltage, lock or latch-retraction function, fire-alarm behavior when specified, and electrical performance during startup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cp\u003eOne \u003cstrong\u003eCommand Access PS210\u003c\/strong\u003e regulated linear \u003cstrong\u003e24VDC power supply\u003c\/strong\u003e in a metal enclosure with one solid-state input\/output channel. Verify the manufacturer's supplied hardware and connector package for this order.\u003c\/p\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cp\u003eElectrified door lock, electric strike, exit device, magnetic lock, access-control controller, independent power distribution board, backup battery, cam lock, door wiring, conduit or electrical installation labor. This listing is for the \u003cstrong\u003ePS210 enclosed power supply\u003c\/strong\u003e only.\u003c\/p\u003e","brand":"Command Access Technologies","offers":[{"title":"Default Title","offer_id":68030630297815,"sku":"PS210","price":238.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/COM_PS210.png?v=1794339176","url":"https:\/\/shop.commercialdoorworx.com\/products\/command-access-ps210-24vdc-linear-power-supply-1-5a-continuous-2-5a-boost","provider":"Commercial Door Worx","version":"1.0","type":"link"}