- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Command Access Request-to-Exit Switch Kit | Motorized Jackson, Kawneer & AHT Exit Devices
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Command Access Request-to-Exit Switch Kit | Motorized Jackson, Kawneer & AHT Exit Devices
Command Access Request-to-Exit Switch Kit | Motorized Jackson, Kawneer & AHT Exit Devices
$95.00
$66.50
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Add monitored exit signaling to an approved motorized panic device with the Command Access Technologies PD15REXKIT-M-ED Field-Installable Request-to-Exit (REX) Switch Kit. This hardware-specific retrofit accessory is designed for Command Access motorized exit-device configurations, including the MLRK1-JAC12 Jackson/Kawneer latch-retraction family and compatible PD15/PD16, AHT 8000/9000, Jackson 1285/1295 and Kawneer 1686/1786 applications as defined in the manufacturer's current compatibility documentation.
Motorized Exit-Device REX Selection
The PD15REXKIT-M-ED is specifically identified for compatible motorized exit-device platforms, including select Jackson, Kawneer and AHT applications. Do not interchange it with a REX kit intended only for mechanical or solenoid-driven hardware.
- Before ordering: Record the host device’s complete model and retrofit motor kit, then verify current compatibility documentation and wiring harness revision.
- Signal function: Use the REX contact to report an inside exit actuation to the access controller; confirm dry-contact type and allowable electrical load per manufacturer instructions.
- Field testing: Verify motor actuation and latch retraction separately from REX monitoring, including the correct control-panel signal during manual egress.
The switch detects compatible exit-device pushpad operation and provides an electrical signal to a connected access-control or security input. This makes it possible to recognize an egress event, coordinate approved door alarm behavior, or log use of the interior panic bar. PD15REXKIT-M-ED is a REX monitoring switch kit, not a motorized latch-retraction assembly, complete exit device or standalone access controller.
Key Features and Benefits
- Built for motorized exit-device applications: The -M-ED designation identifies the field-installable REX option intended for Command Access motorized conversions. Choose this version rather than the standard PD15REXKIT-ED mechanical-device kit when the manufacturer specifies the motorized configuration.
- Jackson and Kawneer compatibility: Listed as a field REX upgrade for MLRK1-JAC12 motorized latch retraction, covering approved Jackson and Kawneer exit-device applications.
- Broader compatible motorized platforms: Supplier references identify Command Access motorized PD15/16, AHT 8/9 and Jackson 1285/1295 exit devices. Check the precise model and electrification type before ordering.
- Integrated pushpad monitoring: Switch changes state when the approved exit-device pushpad is operated, providing an egress indication to the associated security or access-control panel.
- Field-installable accessory: Allows the REX feature to be added to an existing compatible motorized device without ordering a complete replacement motor or panic bar.
- Dry-contact request-to-exit concept: For connection to an appropriate monitored input. Confirm common/normally-open/normally-closed options, conductor identification, and electrical limits using the actual kit's wiring sheet.
- Preserves normal mechanical egress: The exit device remains mechanically operable for code-compliant egress when the retrofit is installed and tested properly.
- Commercial access-control applications: Useful for institutional, educational, healthcare, office and retail doors that already use a compatible Command Access motorized exit-device system.
- Manufacturer-backed product family: Command Access publishes a limited three-year warranty on its exit-device switch kit family, subject to current factory terms.
Technical Specifications
| Brand / Manufacturer | Command Access Technologies |
|---|---|
| Manufacturer SKU | PD15REXKIT-M-ED |
| Product Category | Field-installable request-to-exit switch kit / exit-device accessory |
| Primary Application | Compatible Command Access motorized exit-device applications, including MLRK1-JAC12 |
| Named Compatible Platforms | Motorized PD15/16, AHT 8000/9000, Jackson 1285/1295 and compatible Kawneer series (verify precise model) |
| Jackson/Kawneer Retrofit | MLRK1-JAC12 motorized latch retraction family |
| Switch Function | Detects activation of exit-device pushpad and reports a REX event |
| Installation Type | Field-installable internal switch accessory |
| Signal Output | Switch contact to compatible access-control / security monitoring input; verify wiring instructions |
| Contact Rating | Check the supplied motorized REX switch and current factory documentation; do not assume the rating of a different kit |
| Operating Voltage | REX is a switch accessory, not a standalone powered latch; its contact circuit is determined by the connected monitoring input |
| Motorized Latch Retraction | Not included; compatible motorized device or MLRK1 conversion required |
| Compatible Control | Properly designed low-voltage access-control or monitored security input |
| Warranty | Manufacturer's published three-year limited warranty for exit-device switch kits; current terms apply |
| Shipping Weight | 1 lb estimated packaged shipping weight; verify actual package before shipping |
Motorized vs. Mechanical REX Kits
PD15REXKIT-M-ED is intended for a compatible motorized Command Access exit-device retrofit and is the manufacturer-listed field option associated with MLRK1-JAC12. The separately listed PD15REXKIT-ED is a different field kit for appropriate mechanical exit-device configurations. The correct kit depends on the device's exact factory electrification, internal mechanism and motor/solenoid retrofit. These kits should not be treated as interchangeable.
How Request-to-Exit Monitoring Works
On a compatible door, an occupant presses the exit-device pushpad to leave. The retrofit REX switch changes electrical contact state, allowing a connected controller to recognize that the device has been operated. Depending on programmed access-control logic, the panel can log the exit, coordinate a door-position alarm or temporarily suppress a forced-door indication. This switch does not itself retract the latch, energize the existing motor, unlock a door, provide a reader, or change the mechanical egress function.
Installation and Compatibility Checklist
- Identify the installed exit-device manufacturer, model series, length and motorized electrification. Confirm that the proper field REX upgrade is the PD15REXKIT-M-ED rather than the similarly named mechanical kit.
- Verify the current Command Access retrofit matrix for MLRK1-JAC12, Jackson/Kawneer and other compatible motorized devices. Do not assume that every device within a brand's product line is supported.
- Review the manufacturer's specific PD15REXKIT-M-ED instructions for internal switch position, mounting components, wire routing and connector arrangement before modifying the panic device.
- Mount the switch using the approved internal parts, ensuring the contact operates consistently with pushpad movement and does not obstruct the motorized latch retraction mechanism.
- Connect the switch conductors to the appropriate controller input, checking the contact diagram, current/voltage rating and any NO/NC requirements for the installed switch.
- Test the REX signal with the exit-device pushpad at rest and when pressed, and verify that motorized retraction, mechanical egress, latching and door-alarm coordination still function correctly.
- Confirm fire-rating, exit-device listing, emergency-egress and accessibility requirements for the complete opening before returning the door to service.
What's Included and What's Not
Included: One Command Access PD15REXKIT-M-ED field-installable request-to-exit switch kit intended for approved motorized exit-device applications. Verify the current factory packing list for the exact switch assembly, mounting fasteners, lead wires, labels and documentation.
Not included: The Jackson, Kawneer, AHT or PD15/16 panic device; a separate MLRK1-JAC12 motorized latch-retraction kit; access controller, credential reader, power supply, door power-transfer hardware, door or frame. This product is a monitoring accessory, not an entire electric door-locking system.