{"product_id":"command-access-request-to-exit-switch-retrofit-kit-adams-rite-8400-8600-8800","title":"Command Access Request-to-Exit Switch Retrofit Kit | Adams Rite 8400, 8600 \u0026 8800","description":"\u003cp\u003eThe \u003cstrong\u003eCommand Access Technologies Request-to-Exit (REX) Switch Retrofit Kit\u003c\/strong\u003e adds an electrical monitoring signal to compatible \u003cstrong\u003eAdams Rite 8400, 8600 and 8800 Series\u003c\/strong\u003e commercial exit devices. Designed for \u003cstrong\u003efield installation\u003c\/strong\u003e, this switch detects operation of the exit-device pushpad from the secured side of the opening and sends a signal to a connected access-control or security panel. It allows the door's normal mechanical egress action to be monitored without installing a separate wall-mounted request-to-exit button.\u003c\/p\u003e\u003ch3\u003eREX Signal Integration and Compatibility\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eARREXKIT-ED\u003c\/strong\u003e is intended to add an electrical \u003cstrong\u003erequest-to-exit\u003c\/strong\u003e event indication to approved Adams Rite 8400, 8600 and 8800 exit devices. It is a monitoring accessory rather than an electrification or latch-retraction kit; it does not independently retract the latch or unlock the door.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit check:\u003c\/strong\u003e Identify the exact device series, internal mechanism and available switch mounting location. Follow the manufacturer’s current retrofit instructions rather than assuming all Adams Rite versions use identical switch locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact integration:\u003c\/strong\u003e Map the specified switch terminals to the controller’s REX input and verify input type, contact state and any egress shunt timing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Test REX actuation during normal pushpad operation, switch reset on release and uninterrupted manual egress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis \u003cstrong\u003eARREXKIT-ED\u003c\/strong\u003e model is intended for compatible \u003cstrong\u003emechanical or solenoid-operated Adams Rite exit devices\u003c\/strong\u003e. Motorized Adams Rite exit devices require a different Command Access REX kit, such as the \u003cstrong\u003eARREXKIT-M-ED\u003c\/strong\u003e, as specified in the manufacturer compatibility matrix.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Adams Rite compatibility:\u003c\/strong\u003e Designed for compatible \u003cstrong\u003eAdams Rite 8400, 8600 and 8800 Series\u003c\/strong\u003e exit devices. Always identify the existing hardware and verify installation clearances before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequest-to-exit monitoring:\u003c\/strong\u003e Detects interior pushpad operation and provides a control-panel signal to record an exit event or coordinate an approved access-control sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-installable retrofit:\u003c\/strong\u003e Adds a REX switch to supported existing exit devices, often without replacing the complete panic bar or adding a standalone door-side sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPDT contact design:\u003c\/strong\u003e The single-pole, double-throw switch provides \u003cstrong\u003ecommon, normally open and normally closed\u003c\/strong\u003e contacts for compatible panel input configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple three-wire connections:\u003c\/strong\u003e The manufacturer's installation sheet identifies \u003cstrong\u003egreen = common (C), blue = normally open (NO), and gray = normally closed (NC)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with supported mechanical and solenoid exit devices:\u003c\/strong\u003e The Command Access application matrix approves this kit for mechanical and solenoid-operated Adams Rite devices, not its separately designated motorized versions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-voltage security interface:\u003c\/strong\u003e Supports monitored exiting as part of a properly designed security and access-control installation. The REX switch is a \u003cstrong\u003esignal contact\u003c\/strong\u003e, not a standalone electrified lock, release controller or power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-use accessory:\u003c\/strong\u003e Useful for commercial doors, retail storefronts, offices, institutional facilities and other openings equipped with approved Adams Rite panic hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer warranty:\u003c\/strong\u003e Command Access publishes a three-year limited warranty for its REX exit-device switch kit family; confirm current terms and installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCommand Access Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003eARREXKIT-ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eField-installable request-to-exit (REX) switch retrofit kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible Exit Devices\u003c\/th\u003e\n\u003ctd\u003eAdams Rite 8400, 8600 and 8800 Series, subject to exact mechanical and electrical configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported Device Types\u003c\/th\u003e\n\u003ctd\u003eCompatible mechanical or solenoid-operated devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotorized Device Compatibility\u003c\/th\u003e\n\u003ctd\u003eNot the designated motorized kit; use the correct ARREXKIT-M-ED or manufacturer-specified motorized alternative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch Configuration\u003c\/th\u003e\n\u003ctd\u003eSPDT – single pole, double throw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Common\u003c\/th\u003e\n\u003ctd\u003eGreen wire (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNormally Open\u003c\/th\u003e\n\u003ctd\u003eBlue wire (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNormally Closed\u003c\/th\u003e\n\u003ctd\u003eGray wire (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries Cut-Sheet Contact Rating\u003c\/th\u003e\n\u003ctd\u003e0.5A at 24V AC\/DC; confirm the actual installed switch rating before applying electrical loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Installation Sheet Rating\u003c\/th\u003e\n\u003ctd\u003eA separate ARREXKIT-ED installation sheet lists 5A at 120V AC\/DC; published ratings differ, so confirm the actual switch marking and current factory documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Wiring\u003c\/th\u003e\n\u003ctd\u003e22 AWG switch wires per series cut sheet; use appropriate protected control wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eReports exit-device pushpad operation to a compatible access-control\/security monitoring input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Accessories\u003c\/th\u003e\n\u003ctd\u003eREX switch assembly and model-specific mounting\/wiring accessories; verify the current factory kit contents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eThree-year limited manufacturer REX kit warranty; current terms apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eHow the Request-to-Exit Switch Works\u003c\/h3\u003e\n\u003cp\u003eWhen an occupant presses the inside panic bar, the REX switch changes contact state. A connected controller can interpret the \u003cstrong\u003eNO or NC contact transition\u003c\/strong\u003e as an authorized exit request or recorded exit event. This signal can be used by a suitably designed access-control system to coordinate unlocking or temporarily suppress a door-forced alarm while the door opens. The REX switch itself \u003cstrong\u003edoes not unlock the door, retract the latch, energize a solenoid or provide access-control logic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation Overview\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm compatibility:\u003c\/strong\u003e Match the existing Adams Rite 8400, 8600 or 8800 device and determine whether it is mechanical, solenoid-operated or motorized. Do not substitute this model for the motorized REX kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the device:\u003c\/strong\u003e Follow the official Command Access instructions to remove the pushpad\/cover and locate the manufacturer-designated switch mounting location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the switch conductors:\u003c\/strong\u003e Fish the wires through the prescribed exit-device holes and route the wiring through an approved door power-transfer path to the monitoring equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount the switch:\u003c\/strong\u003e Use the provided or manufacturer-specified self-tapping screws to position the REX assembly so it reliably changes state as the pushpad operates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminate the contacts:\u003c\/strong\u003e Wire green to \u003cstrong\u003ecommon\u003c\/strong\u003e, blue to \u003cstrong\u003enormally open\u003c\/strong\u003e and gray to \u003cstrong\u003enormally closed\u003c\/strong\u003e as required by the controller input. Verify rating and polarity requirements of the overall low-voltage control circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest before closing:\u003c\/strong\u003e Check continuity at the released and pressed pushpad positions. Verify the monitoring panel receives the appropriate exit event, then replace the device cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the complete opening:\u003c\/strong\u003e Test free mechanical egress, proper latching, alarm coordination and any fire-rated-door or life-safety requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eSecurity-monitored commercial storefront entrances, institutional exit doors, schools, office suites, healthcare administrative spaces and other access-controlled openings where a compatible Adams Rite exit device needs \u003cstrong\u003epushpad-based request-to-exit monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePackage and Ordering Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e One factory-specified \u003cstrong\u003eCommand Access ARREXKIT-ED\u003c\/strong\u003e retrofit switch kit for supported Adams Rite exit devices. Manufacturer and distributor documents identify a switch assembly, mounting screws, wiring accessories, labeling and\/or installation instructions; confirm current carton contents for the supplied revision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e Adams Rite exit device\/panic bar, access controller, separate electrified latch-retraction system, wiring transfer, external power supply or motorized-device REX conversion kit. This is \u003cstrong\u003eone field-installable monitoring switch accessory\u003c\/strong\u003e, not a complete exit-device system.\u003c\/p\u003e","brand":"Command Access Technologies","offers":[{"title":"Default Title","offer_id":68023168729303,"sku":"ARREXKIT-ED","price":66.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/COM_REX-KIT.png?v=1794252138","url":"https:\/\/shop.commercialdoorworx.com\/products\/command-access-request-to-exit-switch-retrofit-kit-adams-rite-8400-8600-8800","provider":"Commercial Door Worx","version":"1.0","type":"link"}