{"product_id":"command-access-request-to-exit-switch-retrofit-kit-precision-2000-series-exit-devices","title":"Command Access Request-to-Exit Switch Retrofit Kit | Precision 2000 Series Exit Devices","description":"\u003cp\u003eThe \u003cstrong\u003eCommand Access Technologies Request-to-Exit (REX) Switch Retrofit Kit\u003c\/strong\u003e provides a dedicated field-installable monitoring accessory for compatible \u003cstrong\u003ePrecision 2000 Series commercial exit devices\u003c\/strong\u003e. When the exit-device pushpad is operated, the switch sends a dry-contact signal to a compatible access-control or security panel, helping the system recognize an authorized exit event. Designed for existing mechanical and select solenoid-equipped Precision 2000 devices, the \u003cstrong\u003ePREREXKIT-ED\u003c\/strong\u003e allows an appropriately specified opening to gain monitored exit functionality without replacing the entire panic device.\u003c\/p\u003e\u003ch3\u003eMonitoring Function and Retrofit Verification\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003ePREREXKIT-ED\u003c\/strong\u003e provides a discrete REX status signal for the compatible \u003cstrong\u003ePrecision 2000 Series\u003c\/strong\u003e exit-device mechanisms named in the manufacturer instructions. It does not motorize the exit bar or replace required mechanical panic or fire-exit functionality.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice survey:\u003c\/strong\u003e Verify the exact Precision 2000 model, mechanical versus electrically operated configuration, pushpad travel and compatibility notes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController planning:\u003c\/strong\u003e Use the manufacturer’s electrical contact rating and terminal diagram to connect REX monitoring; REX signaling is not the same as a latchbolt monitor or door-position switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Confirm correct contact transition, reset and controller event interpretation throughout normal inside-exit operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision 2000 compatibility:\u003c\/strong\u003e Manufacturer's REX retrofit kit specifically for the \u003cstrong\u003ePrecision 2000 Series\u003c\/strong\u003e exit-device platform. Confirm the exact installed model, device function and hardware revision before purchasing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical and solenoid device support:\u003c\/strong\u003e The Command Access compatibility chart identifies PREREXKIT-ED for supported mechanical and solenoid exit devices, \u003cstrong\u003enot for motorized exit-device conversions\u003c\/strong\u003e. Do not substitute it for an unrelated MLRK motorized REX configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePushpad-based request-to-exit:\u003c\/strong\u003e Detects mechanical panic-bar movement from the egress side and supplies an electrical contact transition that a connected controller can use for exit-event recognition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPDT monitoring contact:\u003c\/strong\u003e A \u003cstrong\u003esingle-pole, double-throw (SPDT)\u003c\/strong\u003e switch offers a common terminal and normally-open\/normally-closed contact paths for the required monitoring circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-voltage dry-contact interface:\u003c\/strong\u003e The manufacturer switch-kit family is published with a \u003cstrong\u003e0.5 A at 24V AC\/DC\u003c\/strong\u003e contact rating and \u003cstrong\u003e22-gauge wire leads\u003c\/strong\u003e. Check current factory instructions and the supplied switch label before connecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-installable design:\u003c\/strong\u003e Enables qualified technicians to add monitoring to an existing compatible exit device using manufacturer-specified internal mounting points and wire routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess-control integration:\u003c\/strong\u003e Useful for triggering an exit-request input, logging egress activity or coordinating a properly designed door alarm function without changing the physical means of egress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintains mechanical free egress:\u003c\/strong\u003e Proper installation leaves the normal pushpad and latch operation intact; the switch is a monitoring accessory and does not power the latch or control the door lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial facility application:\u003c\/strong\u003e Designed for appropriately specified schools, offices, government facilities, institutional buildings, healthcare administrative areas and commercial buildings equipped with Precision exit hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-year manufacturer warranty:\u003c\/strong\u003e The published Command Access exit-device switch kit family includes a three-year limited warranty; current terms and approved installation requirements apply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCommand Access Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer SKU\u003c\/th\u003e\n\u003ctd\u003ePREREXKIT-ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eField-installable request-to-exit switch retrofit kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible Series\u003c\/th\u003e\n\u003ctd\u003ePrecision 2000 Series commercial exit devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible Electrification\u003c\/th\u003e\n\u003ctd\u003eSupported mechanical and solenoid-operated exit devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotorized Device Compatibility\u003c\/th\u003e\n\u003ctd\u003eNot listed as compatible with motorized devices; use a manufacturer-approved motorized REX option where required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch Configuration\u003c\/th\u003e\n\u003ctd\u003eSPDT (single-pole, double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Interface\u003c\/th\u003e\n\u003ctd\u003eCommon (C), normally open (NO) and normally closed (NC) monitoring contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Family Contact Rating\u003c\/th\u003e\n\u003ctd\u003e0.5 A at 24V AC\/DC; verify rating on the supplied switch and current factory literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished Family Lead Wire\u003c\/th\u003e\n\u003ctd\u003e22 AWG; refer to the supplied PREREXKIT-ED instructions for specific conductor colors and terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring Trigger\u003c\/th\u003e\n\u003ctd\u003eMovement or actuation of the compatible exit-device pushpad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eNot a self-powered locking system; connect dry-contact output to a compatible low-voltage monitoring input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRetrofit Format\u003c\/th\u003e\n\u003ctd\u003eField-installable internal exit-device accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Hardware\u003c\/th\u003e\n\u003ctd\u003eSwitch assembly and model-specific installation components; verify factory carton contents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Warranty\u003c\/th\u003e\n\u003ctd\u003eThree-year limited warranty for Command Access exit-device switch kit family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat Does the REX Kit Do?\u003c\/h3\u003e\n\u003cp\u003eIn a properly configured access-control opening, a request-to-exit switch informs the access controller that a person has pressed the exit-device pushpad to leave the secured area. The panel may use that input to recognize or log an exit event and to apply its programmed door-alarm behavior. \u003cstrong\u003eThe switch does not release an electric lock, retract the latch, energize a solenoid or replace the controller.\u003c\/strong\u003e Its only role is to provide the appropriate switch signal from a compatible Precision device.\u003c\/p\u003e\n\u003ch3\u003ePrecision 2000 Compatibility Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePREREXKIT-ED\u003c\/strong\u003e is the manufacturer-designated field-installable REX switch for the Precision 2000 Series. It is shown as compatible with \u003cstrong\u003emechanical and solenoid-operated configurations\u003c\/strong\u003e in Command Access documentation, while \u003cstrong\u003emotorized applications are excluded\u003c\/strong\u003e from this switch-kit entry. Verify the actual Precision model and the available switch mounting and internal space before ordering. This Precision kit is distinct from the Adams Rite \u003cstrong\u003eARREXKIT-ED\u003c\/strong\u003e, Von Duprin \u003cstrong\u003eVDREXKIT-ED\u003c\/strong\u003e and other hardware-specific REX kits.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify device identification:\u003c\/strong\u003e Confirm an approved Precision 2000 Series mechanical or solenoid-equipped exit device and check that the selected kit matches the manufacturer's latest compatibility matrix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview the factory instructions:\u003c\/strong\u003e Locate the specified switch installation position, pushpad contact point, mounting hardware and wire routing for this Precision model. Do not use a different manufacturer's drilling template.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreserve normal exit function:\u003c\/strong\u003e Install the switch without restricting pushpad travel, latch engagement, trim operation, dogging or emergency egress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the monitoring conductors:\u003c\/strong\u003e Terminate common, normally-open or normally-closed contacts as required by the security system. Confirm conductor colors using the \u003cstrong\u003especific PREREXKIT-ED kit instructions\u003c\/strong\u003e, not an unrelated REX kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck contact ratings:\u003c\/strong\u003e Do not route lock power or an unsuitable load through the REX switch. Match the panel input and low-voltage wiring to the manufacturer's electrical limitations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest all operating modes:\u003c\/strong\u003e Verify that the switch changes state when the pushpad is pressed, the controller detects the intended exit signal, the door relatches normally and emergency egress remains available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm compliance:\u003c\/strong\u003e Check applicable fire-door listings, egress, accessibility, and local access-control requirements before returning the opening to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommercial Applications\u003c\/h3\u003e\n\u003cp\u003ePrecision 2000 exit devices serving controlled-access commercial corridors, institutional entrances, school and university buildings, public facilities, office suites, and other security-monitored exits requiring a \u003cstrong\u003epushpad-based request-to-exit signal\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePackage Scope\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e One Command Access \u003cstrong\u003ePREREXKIT-ED\u003c\/strong\u003e field-installable REX switch kit for supported Precision 2000 Series exit devices. Confirm the supplied switch assembly, mounting fasteners, leads and installation sheet against the current manufacturer packing list.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e The Precision 2000 exit device or panic bar, standalone access controller, electric strike, maglock, power supply, separate power transfer, reader, complete solenoid retrofit kit, or motorized-exit-device REX upgrade. This product is a \u003cstrong\u003emonitoring switch kit only\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Command Access Technologies","offers":[{"title":"Default Title","offer_id":68023189340375,"sku":"PREREXKIT-ED","price":66.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/COM_REX-KIT_170925df-29ad-4981-b273-f935f0849bc6.png?v=1794252261","url":"https:\/\/shop.commercialdoorworx.com\/products\/command-access-request-to-exit-switch-retrofit-kit-precision-2000-series-exit-devices","provider":"Commercial Door Worx","version":"1.0","type":"link"}