Commercial Door Worx University Detex Advantex Training Class
Commercial Door Worx University Detex Advantex Training Class
Commercial Door Worx University Detex Advantex Training Class
$1,550.00
/
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Build real-world knowledge of Detex commercial exit hardware with the Commercial Door Worx University Detex Advantex Training Class.
Designed for commercial door technicians, installers, locksmiths, facility-maintenance personnel, and access-control professionals, this hands-on training course focuses on the installation, adjustment, troubleshooting, and service of Detex Advantex exit devices and electrified hardware.
Students gain practical knowledge they can apply in the field—from identifying device configurations and understanding Detex part numbers to setting up delayed egress, latch retraction, alarms, switches, and power/control systems.
Course Overview
The Detex Advantex Training Class is designed to provide practical instruction on commercial panic and fire-exit hardware.
Training topics may include:
-
Advantex exit-device identification
-
Rim exit devices
-
Surface vertical rod devices
-
Concealed vertical rod devices
-
Device sizing and handing
-
Mechanical installation
-
Pushpad and latch adjustment
-
Strike selection and alignment
-
Rod adjustment
-
Outside trim
-
Dogging options
-
Electrified exit-device functions
-
Power supplies and logic controllers
-
Delayed-egress systems
-
Electric latch retraction
-
Request-to-exit switches
-
Exit alarms
-
Weatherized hardware
-
Troubleshooting and repair
-
Replacement-part identification
Detex Advantex Hardware Covered
Training may include applications involving:
Rim Exit Devices
-
Advantex 10 Series
-
Advantex 40 Series
-
Weatherized 10xW / 40xW configurations
Surface Vertical Rod Devices
-
20 Series
-
21 Series Top Rod Only
-
50 Series
-
51 Series Top Rod Only
-
Weatherized configurations
Concealed Vertical Rod Hardware
Instruction may also cover identification and service concepts for applicable Detex concealed vertical rod devices.
Electrified Detex Functions
A major portion of the class focuses on understanding Detex electrified hardware.
Topics may include:
EA – Exit Alarm
Learn how Detex alarmed exit devices monitor unauthorized egress and how the alarm, bypass, and remote signaling functions operate.
EE – Delayed Egress
Understand the operation of Detex delayed-egress hardware, including:
-
15-second delayed release
-
Audible alarm sequence
-
Arming and rearming
-
Nuisance delay
-
Fire-alarm interface
-
Power requirements
-
Cylinder dogging and Less Dogging configurations
ER / EX – Electric Latch Retraction & Request to Exit
Learn how electric latch retraction is used for:
-
Remote unlocking
-
Electronic dogging
-
Access control
-
Automatic door integration
Training can also cover EX Request-to-Exit switching and proper system integration.
EE ER – Delayed Egress with Latch Retraction
Review systems requiring both:
-
Delayed egress
-
Access-control integration
-
Remote unlocking
-
Automatic operator integration
Weatherized Electrified Hardware
Learn how Detex weatherized options differ from standard interior electrified devices and what should be considered when servicing exterior openings.
Power Supplies & Logic Controllers
Students can learn the role of Detex controllers and power supplies in electrified exit-device systems.
Topics may include:
-
12VDC vs. 24VDC systems
-
Filtered and regulated power
-
Device power requirements
-
Fire-alarm inputs
-
Remote reset
-
Remote bypass
-
Relay outputs
-
Battery backup
-
Multi-door applications
-
Troubleshooting power issues
Mechanical Installation
Proper mechanical setup is critical to dependable panic-hardware operation.
Training may cover:
-
Device height and positioning
-
Door preparation
-
Strike installation
-
Latch engagement
-
Pushpad adjustment
-
Device cutting and sizing
-
End-cap installation
-
Rod adjustment
-
Top-latch setup
-
Bottom-latch setup
-
Door and frame alignment
Strike Identification & Adjustment
Learn to identify and properly install common Detex strike configurations, including applications involving:
-
98 Strike
-
99 Strike
-
Rim-device strikes
-
Surface vertical rod strikes
-
Glass-door applications
-
Strike shims and adjustment
Troubleshooting
Hands-on troubleshooting concepts may include:
-
Device will not latch
-
Pushpad will not retract properly
-
Door will not secure
-
Delayed egress will not arm
-
Alarm will not reset
-
Electric latch retraction will not operate
-
REX signal not working
-
Device is binding
-
Rods are out of adjustment
-
Strike is misaligned
-
Power supply problems
-
Fire-alarm interface issues
-
Incorrect wiring
-
Failed or damaged replacement components
Replacement Part Identification
Learn how to identify frequently serviced Detex components such as:
-
Center cases
-
Circuit boards
-
Filler plates
-
End caps
-
Strikes
-
Top latch assemblies
-
Rod components
-
Transformers
-
Power supplies
-
Logic controllers
-
Remote interfaces
-
Alarm components
-
Dogging assemblies
-
Switches
-
Signage
-
Cover locks and keys
This section is especially useful for technicians responsible for diagnosing existing installations and ordering the correct replacement parts.
Who Should Attend?
Recommended for:
-
Commercial door technicians
-
Automatic door technicians
-
Locksmiths
-
Access-control installers
-
Facility-maintenance personnel
-
Door and hardware installers
-
Service managers
-
Project managers
-
Estimators
-
Government maintenance personnel
-
Hospital maintenance teams
-
School maintenance departments
-
Commercial building engineers
Benefits of Training
Participants can develop a better understanding of:
-
How Detex model numbers are configured
-
Which device fits a particular opening
-
Proper installation methods
-
Correct strike selection
-
Electrified-function identification
-
Power and control requirements
-
Field troubleshooting
-
Replacement-part identification
-
Preventive maintenance
-
Life-safety hardware operation
Hands-On Commercial Door Training
Commercial Door Worx University focuses on practical knowledge that technicians can use on actual commercial openings.
Rather than focusing only on product theory, the class is designed around understanding how the hardware:
-
Installs
-
Adjusts
-
Operates
-
Fails
-
Is diagnosed
-
Is repaired
Important Registration Information
Class schedules, training location, available seating, and course duration may vary.
Before registering, verify:
-
Training date
-
Start and end time
-
Training location
-
Available seating
-
Required tools
-
Required experience level
-
Lunch or refreshments
-
Any included training materials
Training content may vary based on the class session and equipment available.
Recently viewed products
Describe your recently viewed products here