- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex 10-800 Series 800 Logic Controller & Power Supply – 120VAC Input / 12-24VDC Output
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex 10-800 Series 800 Logic Controller & Power Supply – 120VAC Input / 12-24VDC Output
Detex 10-800 Series 800 Logic Controller & Power Supply – 120VAC Input / 12-24VDC Output
$2,240.00
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
120VAC Input | Selectable 12/24VDC Output | Up to 2 Doors
Control and power electrified commercial door hardware from one centralized enclosure with the Detex 10-800 Series 800 Logic Controller & Power Supply.
Additional Product Specifications and Ordering Guidance
Electrical Integration and Controller Selection
Power supplies, controller boards, interface modules and factory wiring cables serve specific Detex electrical systems. The selected assembly must match the existing model, revision and approved circuit design. Do not assume a control board alone supplies a full enclosure or that any low-voltage output is compatible with a motor or latch.
Product SKU: DTX10-800.
Hardware Schedule and Ordering Checklist
- Read the original Detex controller or board part number and current revision, then compare the terminal and connector layout.
- Confirm actual input/output ratings, field-wire gauge and voltage drop with the factory service documentation.
- List the connected devices and any fire-alarm input, access-control request, battery backup, reset or external receiver functions.
- Disconnect electrical power and document settings and connections before replacement; use qualified personnel for energized system work.
Installation and Acceptance Checks
Measure and verify control output under normal load, alarm/reset/bypass signaling, any required emergency release and return to proper door operation.
Factory Package Scope
One specified factory electrical component or power/controller assembly; transformer, enclosure, auxiliary batteries and site wiring depend on the actual part number. Preserve and review the original detailed specifications below for the particular Detex model.
Designed for access-control and egress applications, the 10-800 combines a regulated DC power supply and programmable logic controller in one enclosure, simplifying wiring and system integration.
The unit accepts 120VAC input and provides selectable 12VDC or 24VDC output, allowing it to support a wide range of compatible electrified locks, exit devices, access-control components, alarms, and related door hardware.
Key Features
-
Genuine Detex 10-800
-
Series 800 universal logic controller and power supply
-
120VAC input
-
Selectable 12VDC / 24VDC output
-
Provides at least 2 amps of filtered, regulated DC power
-
Controls up to 2 separate doors
-
Supports standard egress applications
-
Supports 2-door interlock applications
-
Output relays for:
-
Electric locks
-
Local alarms
-
Remote alarms
-
-
Multiple fire-alarm relay input options
-
Centralized terminal connections simplify wiring
-
Built-in ON/OFF switch for service and inspection
-
Standard battery charging / backup circuit
-
Designed specifically for electrified door and access-control systems
Complete Stand-Alone Controller
The 10-800 is supplied as a complete stand-alone controller containing:
-
Back box
-
Transformer
-
Series 800 control electronics
Detex lists the 10-800 as a stand-alone 120VAC/24VDC system, with selectable 12/24VDC operation provided through the controller.
Typical Applications
-
Electrified Exit Devices
-
Electric Locks
-
Access Control Systems
-
Controlled Egress Doors
-
Door Interlock Systems
-
Card Reader Systems
-
Keypad-Controlled Entrances
-
Remote Alarm Systems
-
Commercial Security Doors
-
Institutional Access Control
Product Specifications
Brand: Detex
Model: 10-800
Series: Series 800
Product Type: Logic Controller & Power Supply
Input Power: 120VAC
Output Voltage: Selectable 12VDC / 24VDC
DC Output: At Least 2A Filtered & Regulated
Door Capacity: Up to 2 Doors
Battery Charging Circuit: Standard
Battery: Sold Separately
Application: Electrified Door Hardware & Access Control
System Capabilities
The 10-800 can receive inputs from compatible access-control and door-control devices and process those signals through its internal logic and relay outputs.
Typical system integrations may include:
-
Electric locking hardware
-
Exit devices
-
Access-control readers
-
Request-to-exit devices
-
Local alarms
-
Remote alarms
-
Fire-alarm systems
-
Two-door interlock systems
Battery Backup
A battery charging and backup circuit is standard with the controller. Backup batteries are sold separately and should be selected according to the system's voltage, current draw, and required backup duration.
Important: Verify the voltage, amperage requirements, locking hardware, access-control components, fire-alarm interface, and wiring configuration before installation.
Recently viewed products
Describe your recently viewed products here