{"product_id":"detex-10-ee-er-630-rim-exit-device","title":"Detex 10 EE ER 630 Rim Exit Device | 36\" or 48\" | Delayed Egress + Latch Retraction","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eCombine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edelayed-egress security, access control, and powered latch retraction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in one heavy-duty commercial exit device with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 10 EE ER 630 Advantex Rim Exit Device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for demanding commercial and institutional openings, the Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEE ER\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e configuration combines a standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-second delayed-egress function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectric latch retraction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This allows the opening to deter unauthorized egress while also supporting authorized remote unlocking, remote dogging, card-reader access, and automatic-door operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e36\" or 48\" device lengths\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the 10 EE ER features durable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e630 \/ US32D Satin Stainless Steel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e construction and Detex Advantex Grade 1 performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex Advantex 10 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeavy-duty \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erim exit device\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eANSI\/BHMA Grade 1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEE – Delayed Egress\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eER – Electric Latch Retraction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-second delayed-egress period\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 dB alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e through the required system interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuiet electric latch retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote unlocking capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote dogging capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-door operator compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequest-to-Exit monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePushpad monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDeadlatch monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic rearm after authorized entry or exit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired fire-alarm interface for emergency release\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvailable in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e36\" or 48\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e630 \/ US32D Satin Stainless Steel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-handed rim-device design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField sizeable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for extreme high-traffic applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Sizes\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e36\" Device\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-foot commercial doors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e48\" Device\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for commercial doors up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4 feet wide\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChoose the required device length when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEE – Delayed Egress\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEE delayed-egress function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps deter unauthorized use of an emergency exit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen an unauthorized exit attempt occurs:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePressure on the exit device initiates the delayed-egress sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe system's approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 dB alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e sounds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe door remains secured for the standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-second delay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter the required delay expires, egress is permitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eThe delayed-egress function provides facility personnel additional response time while maintaining required life-safety operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eER – Electric Latch Retraction\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eER Electric Latch Retraction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e function electrically retracts the exit-device latch for authorized access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen activated by the compatible Detex controller or access-control system, the latch can retract for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard-reader access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypad access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote door release\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote dogging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-door operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuthorized entry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuthorized exit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the opening to be electronically controlled without requiring an electric strike or magnetic lock for normal authorized access.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEE + ER Combined Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEE and ER functions serve different purposes within the same system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e controls unauthorized exit attempts through delayed egress.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eER\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides powered latch retraction when an authorized electrical signal is received.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe electric latch-retraction function should not be confused with the release that occurs at the end of the delayed-egress cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAccess Control Integration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EE ER configuration is ideal for openings integrated with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard readers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeypads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCredential systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote release stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding access-control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic swing-door operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity-management systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it particularly useful for controlled entrances where both \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eauthorized access and unauthorized-exit prevention\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLogic Controller \/ Power Supply Required\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex logic controller \/ power supply is required and sold separately\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eController selection depends on the specific installation and system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex controller options for EE ER applications provide the required control logic and remote interface functions, including the system alarm and status indication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the appropriate controller before ordering the complete system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFire Alarm Interface\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDelayed-egress applications require an approved \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efire-alarm interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the required emergency signal is received, the delayed locking function is overridden to permit immediate egress as required by the applicable life-safety system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation must comply with local building and fire codes and requirements of the Authority Having Jurisdiction.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e630 Satin Stainless Steel\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e630 \/ US32D Satin Stainless Steel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e finish provides excellent durability and a professional commercial appearance for high-traffic openings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAirports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional properties\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-use access-controlled openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Advantex 10 Series\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 EE ER 630\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDevice Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rim Exit Device\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Delayed Egress with Electric Latch Retraction\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDelayed Egress:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EE\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLatch Retraction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ER\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eStandard Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 15 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAlarm:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 100 dB through system interface\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAvailable Sizes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 36\" or 48\"\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFinish:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 630 \/ US32D Satin Stainless Steel\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ANSI\/BHMA Grade 1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHanding:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-Handed\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSizing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Field Sizeable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAccess Control Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic Operator Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFire Alarm Interface:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Required\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLogic Controller \/ Power Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Required – Sold Separately\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail loss-prevention exits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals and healthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAssisted living facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAirports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools and universities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarehouses\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistribution centers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-door openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestricted-access areas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Ordering Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLogic controller \/ power supply is required and sold separately.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e36\" or 48\" device length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor width\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRequired strike\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-operator requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eController requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-alarm interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTrim and cylinder requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocal delayed-egress code requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e","brand":"Detex","offers":[{"title":"36 Inch","offer_id":48287177933015,"sku":"DTX10-EER-630-CD-99-36","price":0.0,"currency_code":"USD","in_stock":true},{"title":"48 Inch","offer_id":48287177965783,"sku":"DTX10-EER-630-CD-99-48","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/10EEER_4b099878-e204-40ed-ac1f-823f220c5281.jpg?v=1770925831","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-10-ee-er-630-rim-exit-device","provider":"Commercial Door Worx","version":"1.0","type":"link"}