{"product_id":"detex-102850-2-er-ex-control-module","title":"Detex 102850-2 ERxEX Control Module – Electric Latch Retraction \/ Request-to-Exit Module","description":"\u003ch1 data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eDetex 102850-2 ERxEX Control Module\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectric Latch Retraction \/ Request-to-Exit Module | Advantex Series Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRestore the electrified operation of compatible Detex Advantex exit hardware with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 102850-2 ERxEX Control Module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned as a genuine replacement component for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdvantex ER EX exit device assemblies\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this module supports the system's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectric latch retraction and request-to-exit functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ER EX system allows compatible Detex exit devices to retract the latch and pushpad electrically for applications such as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eremote unlocking, access control, automatic door operation, and remote dogging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 102850-2\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdvantex Series replacement module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eER × EX configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectric Latch Retraction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequest-to-Exit signaling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible electrified Detex Advantex exit devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports momentary or maintained latch retraction applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnables simultaneous latch and pushpad retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with access-control applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for automatic door operator integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for commercial exit-device repair and service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFactory replacement component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eER EX Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eER EX – Electric Latch Retraction with Request-to-Exit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e function electrically retracts the exit device latch and pushpad.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote Door Unlocking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess Control Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard Reader Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic Door Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote Dogging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControlled Entry Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEX request-to-exit function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides signaling when the pushpad is operated. Detex uses a continuous-duty motor rather than a solenoid for quiet operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetex Advantex Exit Devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrified Panic Hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial Entrance Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic Door Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-Controlled Openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment Facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAirports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOffice Buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail Facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Traffic Commercial Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 102850-2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ERxEX Replacement Module\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Advantex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electric Latch Retraction \/ Request-to-Exit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSystem Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24VDC ER EX System\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electrified Commercial Exit Devices\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Replacement Module\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex lists ER EX as an electrified function available on multiple Advantex rim, mortise, surface vertical rod, and concealed vertical rod exit-device configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePower \u0026amp; Controller Requirements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe complete ER EX installation requires a compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24VDC power\/control system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e sized for the Detex latch-retraction hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex's current controller lineup should be verified when replacing or upgrading an older installation, as legacy Series 800 latch-retraction controllers have been superseded in Detex's current product line.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Verify the existing Advantex exit device model, ER EX configuration, wiring, controller, power supply, and module compatibility before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":49606745981143,"sku":"DTX102850-2","price":1155.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/Detex-Logo.webp?v=1781625364","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-102850-2-er-ex-control-module","provider":"Commercial Door Worx","version":"1.0","type":"link"}