Replacement Door Controller PWA | EE / ER Delayed Egress & Electric Latch Retraction | Detex 84-800
Restore control functionality in a compatible Detex electrified-door system with the Detex 102879-3 Logic Controller, a replacement Door Controller PWA designed for Detex systems combining Delayed Egress (EE) with Electric Latch Retraction (ER).
Detex factory documentation specifically identifies 102879-3 as the Door Controller PWA inside the 84-800 Controller / Power Supply, which is designed for a single-door EExER delayed-egress with latch-retraction application.
This listing is for the controller circuit board only and is intended for service, repair, and replacement of compatible Detex control systems.
Key Features
-
Genuine Detex replacement controller board
-
Part Number: 102879-3
-
Door Controller PWA
-
Designed for compatible EE / ER systems
-
Used in the Detex 84-800 Controller / Power Supply
-
Supports electric latch-retraction control
-
Interfaces with delayed-egress control circuitry
-
Multiple dry-contact control inputs
-
Adjustable latch-retraction hold time
-
Door-operator signal relay
-
Adjustable door-operator signal delay
-
Onboard activity indicators
-
Commercial access-control replacement component
-
Circuit board only
-
Complete power supply not included
Designed for Detex 84-800 Systems
Detex identifies the 84-800 as a controller and power-supply system for:
Single Door Delayed Egress with Latch Retraction – EExER
Within the 84-800 enclosure, the major control components include:
-
102879-3 Door Controller PWA
-
Delayed Egress PWA
-
Regulated power-supply board
-
Opto-isolator circuitry
The 102879-3 handles the latch-retraction and related door-control functions within that system.
Electric Latch Retraction Control
The controller provides output control for the compatible Detex ER electric latch-retraction device.
When an approved access-control input is activated, the board can energize the latch-retraction output to retract the exit-device latch for authorized access or door operation.
Detex identifies three normally-open dry-contact control inputs on the controller.
Adjustable Latch Hold Time
The controller provides an adjustable latch-retraction hold delay.
Detex specifies an adjustment range of up to approximately:
30 Seconds
The hold-time adjustment determines how long the latch remains retracted after the initiating control input is released.
Door Operator Signal
The 102879-3 controller also provides an auxiliary SPDT dry-contact door-operator signal.
This output can be used to signal a compatible automatic door operator or other equipment after the latch has retracted.
Detex identifies the relay terminals as:
-
Normally Closed
-
Common
-
Normally Open
Adjustable Operator Delay
The automatic-door operator signal can be delayed after latch retraction.
Detex specifies an adjustable delay of approximately:
0.5 to 3 Seconds
This allows the electric latch to retract before the automatic operator begins opening the door.
EE-to-ER Timing
In the 84-800 EExER application, the system also provides an adjustable timing relationship between the delayed-egress release and latch retraction.
Detex identifies this differential adjustment at approximately:
0.25 to 1 Second
This adjustment is factory set and typically does not require field modification.
Onboard Indicators
The controller includes visual indicators for system operation and troubleshooting.
Detex documentation identifies indicators for:
-
Controller power
-
Door output activity
-
Auxiliary output activity
These LEDs help technicians diagnose control and output conditions during installation or service.
24VDC System Application
Within the Detex 84-800 system, the power supply is configured for 24VDC, and the controller's power indicator confirms when 24V is being supplied to the board.
The 102879-3 should be treated as a replacement system board, not as a standalone power supply.
Product Specifications
Manufacturer: Detex
Part Number: 102879-3
Product Type: Door Controller PWA / Logic Controller
Primary Application: EE / ER Door Control
Compatible System: Detex 84-800
Application Type: Single-Door Delayed Egress + Latch Retraction
System Voltage: 24VDC in 84-800 configuration
Control Inputs: Normally Open Dry Contact
Latch Hold Adjustment: Up to Approx. 30 Seconds
Door Operator Relay: SPDT Dry Contact
Operator Delay: Approx. 0.5–3 Seconds
EE-to-ER Differential: Approx. 0.25–1 Second
Mounting: Inside Compatible Detex Control Enclosure
Use: Replacement / Repair / Service
Common Applications
Ideal for servicing compatible Detex systems installed at:
-
Delayed-egress doors
-
Access-controlled exits
-
Healthcare facilities
-
Hospitals
-
Assisted living facilities
-
Schools
-
Government buildings
-
Secure institutional facilities
-
Commercial access-controlled openings
-
Automatic door applications with latch retraction
Replacement Applications
Replace the 102879-3 when the existing controller board has been properly diagnosed as:
-
Failed
-
Damaged
-
Producing unreliable latch-retraction output
-
Failing to respond to access-control inputs
-
No longer producing the proper operator signal
-
Damaged from electrical faults or component failure
Troubleshoot the complete system before replacing the board, including the power supply, exit device, wiring, delayed-egress board, and connected controls.
Important Compatibility Note
The 102879-3 is not a universal standalone access-control panel.
Detex factory documentation specifically shows it as the Door Controller PWA in the 84-800 EExER system.
Before ordering, verify:
-
Existing controller part number is 102879-3
-
Detex system model
-
Existing EE / ER configuration
-
Power-supply condition
-
Delayed-egress controller
-
Exit-device model
-
Existing wiring
-
Door-operator interface requirements
Do not substitute another 102879 revision solely because the boards appear similar.