{"product_id":"detex-102879-3-logic-door-controller","title":"Detex 102879-3 Logic Controller | EE\/ER Door Controller PWA","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Door Controller PWA | EE \/ ER Delayed Egress \u0026amp; Electric Latch Retraction | Detex 84-800\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRestore control functionality in a compatible Detex electrified-door system with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 102879-3 Logic Controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a replacement \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDoor Controller PWA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for Detex systems combining \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDelayed Egress (EE)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectric Latch Retraction (ER)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex factory documentation specifically identifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e102879-3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as the Door Controller PWA inside the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e84-800 Controller \/ Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which is designed for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-door EExER delayed-egress with latch-retraction application\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis listing is for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtroller circuit board only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is intended for service, repair, and replacement of compatible Detex control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex replacement controller board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePart Number: 102879-3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor Controller PWA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEE \/ ER systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUsed in the Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e84-800 Controller \/ Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports electric latch-retraction control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with delayed-egress control circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple dry-contact control inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable latch-retraction hold time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor-operator signal relay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable door-operator signal delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOnboard activity indicators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial access-control replacement component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCircuit board only\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eComplete power supply not included\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for Detex 84-800 Systems\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDetex identifies the 84-800 as a controller and power-supply system for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSingle Door Delayed Egress with Latch Retraction – EExER\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWithin the 84-800 enclosure, the major control components include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e102879-3 Door Controller PWA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDelayed Egress PWA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRegulated power-supply board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOpto-isolator circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe 102879-3 handles the latch-retraction and related door-control functions within that system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectric Latch Retraction Control\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe controller provides output control for the compatible Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eER electric latch-retraction device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen an approved access-control input is activated, the board can energize the latch-retraction output to retract the exit-device latch for authorized access or door operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex identifies three normally-open dry-contact control inputs on the controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdjustable Latch Hold Time\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe controller provides an adjustable latch-retraction hold delay.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex specifies an adjustment range of up to approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e30 Seconds\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe hold-time adjustment determines how long the latch remains retracted after the initiating control input is released.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDoor Operator Signal\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 102879-3 controller also provides an auxiliary \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSPDT dry-contact door-operator signal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis output can be used to signal a compatible automatic door operator or other equipment after the latch has retracted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex identifies the relay terminals as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Closed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNormally Open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAdjustable Operator Delay\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe automatic-door operator signal can be delayed after latch retraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex specifies an adjustable delay of approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e0.5 to 3 Seconds\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis allows the electric latch to retract before the automatic operator begins opening the door.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEE-to-ER Timing\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIn the 84-800 EExER application, the system also provides an adjustable timing relationship between the delayed-egress release and latch retraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex identifies this differential adjustment at approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e0.25 to 1 Second\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis adjustment is factory set and typically does not require field modification.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOnboard Indicators\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe controller includes visual indicators for system operation and troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex documentation identifies indicators for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eController power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor output activity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary output activity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese LEDs help technicians diagnose control and output conditions during installation or service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e24VDC System Application\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWithin the Detex 84-800 system, the power supply is configured for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the controller's power indicator confirms when 24V is being supplied to the board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 102879-3 should be treated as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereplacement system board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not as a standalone power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 102879-3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Door Controller PWA \/ Logic Controller\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePrimary Application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EE \/ ER Door Control\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex 84-800\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single-Door Delayed Egress + Latch Retraction\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSystem Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24VDC in 84-800 configuration\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Inputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Normally Open Dry Contact\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLatch Hold Adjustment:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to Approx. 30 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDoor Operator Relay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SPDT Dry Contact\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOperator Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 0.5–3 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eEE-to-ER Differential:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 0.25–1 Second\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Inside Compatible Detex Control Enclosure\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eUse:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Replacement \/ Repair \/ Service\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for servicing compatible Detex systems installed at:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDelayed-egress doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled exits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAssisted living facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure institutional facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial access-controlled openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic door applications with latch retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eReplacement Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReplace the 102879-3 when the existing controller board has been properly diagnosed as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDamaged\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProducing unreliable latch-retraction output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailing to respond to access-control inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo longer producing the proper operator signal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDamaged from electrical faults or component failure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTroubleshoot the complete system before replacing the board, including the power supply, exit device, wiring, delayed-egress board, and connected controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Compatibility Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e102879-3 is not a universal standalone access-control panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex factory documentation specifically shows it as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDoor Controller PWA in the 84-800 EExER system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting controller part number is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e102879-3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetex system model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting EE \/ ER configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower-supply condition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDelayed-egress controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit-device model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoor-operator interface requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDo not substitute another 102879 revision solely because the boards appear similar.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e(1) Detex 102879-3 Door Controller PWA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":47295879839959,"sku":"DTX102879-3","price":346.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/102879-3.png?v=1768243581","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-102879-3-logic-door-controller","provider":"Commercial Door Worx","version":"1.0","type":"link"}