{"product_id":"detex-104252-red-pcb-ao19-power-supply","title":"Detex 104252 Red PCB | AO19 \/ 90-800 Power Supply Circuit Board","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cstrong\u003e\u003cspan\u003eOEM Replacement Power Supply PCB | 24VDC | Detex AO19 \u0026amp; 90-800 Applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRestore a compatible Detex automatic-door or electrified-door power supply with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 104252 Printed Circuit Board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, commonly identified as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ered replacement PCB\/PWA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e104252\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the factory replacement circuit board used in the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 90-800 Filtered Regulated Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which provides regulated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24VDC power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for compatible Detex door-hardware systems. The 104252 is also cataloged by Detex distributors as a replacement PCB for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAO19 automatic door operator power-supply applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex replacement circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePart Number \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e104252\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrinted Circuit Board \/ PWA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommonly identified as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ered PCB\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFactory replacement board for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 90-800\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUsed with compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAO19 automatic door operator power-supply systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRegulated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e24VDC output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFiltered DC power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-loop input circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable DC output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOnboard status LEDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectronic overload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement board only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransformer and enclosure sold separately unless specifically stated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Product Identification\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e104252 is a power-supply circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt should not be confused with the separate:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAO19 Operator Controller \/ UDC 1000 Controller\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex lists the AO19 operator controller separately in its automatic-operator documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf the automatic door has a movement, programming, or operator-control problem, verify whether the issue is actually with the operator controller before replacing the 104252.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDetex 90-800 Replacement Board\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDetex factory documentation specifically lists:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Circuit Board: PWA 104252\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efor the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90-800 Filtered Regulated Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 90-800 provides:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24VDC regulated and filtered output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efor compatible electrified door-hardware equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e24VDC Power Supply Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWithin the compatible Detex power-supply assembly, the 104252 converts and regulates incoming transformer power into the DC power required by connected door-hardware equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe board includes connections for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransformer input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e24VDC output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-loop monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnected door-hardware loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe complete 90-800 uses a Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e104254 transformer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in conjunction with the 104252 board.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFire Loop Input\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 104252 incorporates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efire-loop input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that allows the compatible power-supply system to interface with an appropriate fire-control circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex provides selectable sensing for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12V fire-loop systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e24V fire-loop systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe fire-control wiring must be configured appropriately for the complete door system and applicable life-safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOnboard Status Indicators\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe circuit board includes LED indicators that assist technicians with troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory documentation identifies indicators for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Input Good\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFire Loop OK\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Output Good\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese indicators can help determine whether the board is receiving power and whether the output and fire-loop circuits are operating correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectronic Overload Protection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 104252 incorporates protection for the DC output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a connected load or wiring develops a short circuit, the output can shut down to protect the power-supply circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex instructs technicians to correct the short or overload condition before reconnecting the load.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAO19 Application\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCurrent commercial distributors catalog \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 104252\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePCB Board, For AO19 Operator\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eor:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePrinted Circuit Board for AO19 Power Supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor catalog accuracy, the 104252 should be considered a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epower-supply PCB used in compatible AO19 installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, rather than the electronic controller that directly programs and controls operator movement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 104252\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Printed Circuit Board \/ PWA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCommon Identification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Red PCB\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePrimary Factory Application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex 90-800 Power Supply\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAO19 Application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible Power-Supply Replacement PCB\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSystem Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24VDC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePower Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Filtered \/ Regulated\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFire Loop:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12V \/ 24V Selectable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indicators:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Power Input, Fire Loop, Power Output\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Transformer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex 104254 in 90-800 assembly\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eInstallation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Inside Compatible Detex Power-Supply Enclosure\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eUse:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Replacement \/ Repair \/ Service\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eUsed in compatible systems serving:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetex AO19 automatic door operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrified exit devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric latch-retraction systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial automatic doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eReplacement Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReplace the 104252 when the existing PCB has been properly diagnosed with issues such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo 24VDC output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed power-output circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-loop circuit failure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible PCB damage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed electronic components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent power output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways test the transformer, wiring, connected load, and downstream hardware before replacing the board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA shorted device or wiring fault can cause the board's output protection to activate even when the PCB itself is functioning correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Compatibility Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify the existing board is marked:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDETEX P\/N 104252\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlso confirm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting power-supply model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAO19 system configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransformer condition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInput voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnected hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-loop configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExisting board revision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDetex has used later board revisions in newer controller and power-supply assemblies, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e104252-3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so matching the complete part number and system configuration is important before substitution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation \u0026amp; Safety\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eInstallation should be performed by qualified personnel familiar with commercial automatic-door and low-voltage access-control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisconnect incoming power before servicing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify transformer output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCorrect short circuits before installing a replacement board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain separation of high- and low-voltage wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm fire-control connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow applicable electrical and life-safety requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eDetex specifically warns that the enclosure should not be opened or serviced while energized.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e(1) Detex 104252 Printed Circuit Board \/ PWA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":47304120860887,"sku":"DTX104252RED","price":282.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/104252RedBoard.png?v=1760730568","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-104252-red-pcb-ao19-power-supply","provider":"Commercial Door Worx","version":"1.0","type":"link"}