{"product_id":"detex-105083-eexer-remote-interface-circuit-board-kit","title":"Detex 105083 – EExER Remote Interface Circuit Board Kit For EAX-2500 Keyswitch","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cstrong\u003e\u003cspan\u003eRUI Remote Interface Board | EExER Delayed Egress Systems | Key Cylinder Input | LED \u0026amp; Horn Control | 84-800 \/ 85-800\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 105083 EExER Remote Interface Circuit Board Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a genuine replacement \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRUI circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for compatible Detex delayed-egress and electric latch-retraction systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstalled inside the Detex Remote Interface Unit, the 105083 provides the electrical interface for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ekeyswitch, status LEDs, horn, and controller connection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e used with compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEExER systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis replacement board is commonly used with Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e84-800 and 85-800 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e controller installations and is ideal for repairing a damaged or malfunctioning remote keyswitch\/interface assembly without replacing the complete control station.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex replacement circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetex part number \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e105083\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOfficial designation: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRUI Circuit Board Kit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEExER Remote Interface Units\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 84-800\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex 85-800\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports remote \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ekey-cylinder operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControls \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egreen status LED\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControls \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ered status LED\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides horn connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with the Detex controller\/power supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelectable setup for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ekey cylinder or dummy cylinder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial delayed-egress replacement component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eRemote Interface Functions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex 105083 provides connections for several functions within the Remote Interface Unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSupported Connections\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGreen LED Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRed LED Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKey Cylinder Input\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHorn Negative\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHorn Positive\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGround\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese connections allow the remote interface to provide visual and audible system status while giving authorized personnel keyswitch control of the delayed-egress system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Cylinder \/ Dummy Cylinder Selection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 105083 board includes an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eS2 selector \/ shunt setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that allows the Remote Interface Unit to be configured according to the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Cylinder Application\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSet \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eS2 to ON\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the remote interface uses a functioning key cylinder.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDummy Cylinder Application\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSet \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eS2 to OFF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when a dummy cylinder is used and keyswitch operation is not required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the existing installation before changing the board configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 105083\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Remote Interface Circuit Board Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDetex Description:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RUI Circuit Board Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSystem Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EExER\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Controllers:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 84-800 \/ 85-800\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKey Cylinder Input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGreen LED Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRed LED Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHorn Output Connections:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCylinder Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Keyed or Dummy\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Delayed Egress \/ Electric Latch Retraction\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Location:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Remote Interface Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEExER System Application\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEExER\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e system combines:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDelayed egress\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric latch retraction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote system control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAudible alarm functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStatus indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFire-alarm integration through the associated controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e105083 Remote Interface Board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e serves as the interface between the remote control station and the associated Detex controller\/power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible Detex systems including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e84-800 Single-Door EExER Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e85-800 Two-Door \/ Pair EExER Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDetex Remote Interface Units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKey-operated delayed-egress control stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the existing board part number and system configuration before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eReplacement Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex 105083 is ideal when servicing a remote interface experiencing issues such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeyswitch not controlling the system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStatus LEDs not operating correctly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote horn not functioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDamaged circuit board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCorroded or damaged terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent remote-interface operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed EExER remote control station\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eProper troubleshooting should be performed before replacing the circuit board.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant EAX-2500 Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e105083 is an EExER Remote Interface circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not the standard replacement alarm board used inside a standalone EAX-2500 exit alarm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe EExER remote interface uses a keyswitch-style control assembly with several components also associated with Detex remote alarm\/control hardware, which can lead to it being described as an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEAX-2500-style keyswitch interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epart number 105083\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on the existing board before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation Note\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Detex Remote Interface enclosure must be properly grounded according to the installation instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation and service should be performed by qualified personnel familiar with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDelayed-egress hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrified exit devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-control wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial life-safety systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePower should be disconnected before servicing the Remote Interface Unit or associated controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e(1) Detex 105083 RUI Remote Interface Circuit Board Kit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRemote interface cover, cylinder, cam assembly, horn, LEDs, controller, power supply, wiring harnesses, and other components are sold separately unless specifically stated otherwise.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":47323541668055,"sku":"DTX-105083","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/105083.png?v=1768246244","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-105083-eexer-remote-interface-circuit-board-kit","provider":"Commercial Door Worx","version":"1.0","type":"link"}