- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex 106021 Transformer – 277VAC to 24VAC – 75VA
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex 106021 Transformer – 277VAC to 24VAC – 75VA
Detex 106021 Transformer – 277VAC to 24VAC – 75VA
$180.00
$151.20
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
The Detex 106021 Step-Down Transformer is a factory-designated power component for compatible commercial door-control and exit-alarm installations requiring a 277VAC primary input and 24VAC secondary output. Rated at 75 volt-amperes (75VA), this transformer provides the specified AC voltage conversion for a properly matched Detex system. It is intended for targeted replacement or new equipment installations when the approved electrical parts schedule calls for Detex part number 106021.
Critical voltage requirement: Model 106021 is a 277VAC-input transformer. It is not the correct replacement for a 120VAC-input transformer merely because both have a 24VAC output. Confirm the actual building supply voltage and equipment documentation before ordering or installing.
Key Features and Benefits
- Genuine Detex replacement component: Factory part number 106021 listed by Detex in its Exit Alarms / Power Sources parts catalog.
- 277VAC to 24VAC conversion: Steps down the specified high-voltage AC supply to a nominal 24VAC output for approved compatible equipment.
- 75VA capacity: Clearly identified volt-ampere power rating helps the specifying electrician compare the transformer with the connected equipment's required load.
- AC secondary output: Supplies 24 volts alternating current, not 24VDC. The receiving device must be rated for this voltage type or use a separately specified conversion/control assembly.
- Service replacement option: Allows replacement of a failed or damaged transformer without purchasing an entirely new exit-alarm system when the surrounding equipment remains serviceable.
- Factory part traceability: Manufacturer model 106021 simplifies matching maintenance records, service diagrams and purchasing documentation.
- Commercial application: Intended for properly specified Detex door-security and exit-alarm equipment where this transformer is identified in the manufacturer's parts and electrical documentation.
Electrical Specifications
| Manufacturer | Detex |
|---|---|
| Manufacturer part number | 106021 |
| Component type | AC step-down transformer |
| Primary / input voltage | 277VAC (alternating current) |
| Secondary / output voltage | 24VAC (alternating current) |
| Rated power | 75VA (volt-amperes) |
| Output current | Dependent on the approved transformer rating and connected system; confirm allowable loading with the manufacturer and electrical design |
| Catalog category | Detex exit-alarm power sources and transformer accessories |
| Intended use | Compatible Detex equipment specified for a 277VAC-to-24VAC transformer |
| Quantity | One transformer component |
Understanding the 75VA Rating
75VA describes the transformer's nominal apparent-power capacity, which is not automatically the same as 75 watts for every connected load. The system designer must account for the total connected equipment load, power factor when applicable, startup/inrush requirements, permitted loading, protection and any manufacturer-required capacity margin. A 24VAC label alone does not establish compatibility with an entire access-control or exit-alarm circuit.
Detex System Compatibility
Detex lists model 106021 in its power-source component family. Distributor listings also reference its use with Detex 81-800LT; the exact installation must still be verified using the current equipment-specific wiring diagram and parts list. Do not assume universal compatibility with every Detex ECL, EAX, EE, electromagnetic lock or exit alarm. Each connected unit may require its own specified AC or DC voltage, power supply, rectifier, transformer and circuit protection.
Comparison With Other Detex Transformer Models
- 106021: 277VAC primary to 24VAC secondary, 75VA — the model supplied by this listing.
- PP-5152-2: Separate Detex 120VAC-to-24VAC transformer model with a different power rating; not interchangeable solely on the basis of output voltage.
- PP-5152-3: Separate 120VAC-to-12VAC transformer model; different input and output requirements.
- PP-5452-2: Separate 240VAC-to-12VAC transformer model; not the 277VAC-to-24VAC model.
Selection reminder: Match all required specifications: manufacturer part number, actual input voltage, output voltage and AC/DC type, VA capacity, connected load and approved equipment configuration. Never substitute a transformer based solely on similar appearance or output voltage.
Replacement and Installation Guidance
- Identify the existing component: Confirm Detex part 106021 and compare the current manufacturer's parts information with the transformer being replaced.
- Confirm the circuit: Have a qualified electrician verify that the available primary supply is the specified 277VAC and that the receiving system requires 24VAC output.
- Check system loading: Verify the connected load against the rated 75VA capacity and any system-specific design or derating requirements.
- Review installation requirements: Follow the manufacturer's approved wiring diagram and electrical code requirements for disconnecting means, enclosures, mounting, conductor sizing, grounding and circuit protection.
- Install safely: Primary-side 277VAC work presents a serious electrical-shock and arc-flash hazard. Installation and testing should be performed only by qualified electrical personnel using appropriate de-energization, verification and lockout procedures.
- Commission the system: After installation, qualified personnel should confirm the specified secondary output and test the connected door-security or exit-alarm equipment according to its approved service instructions.
Typical Maintenance Applications
Replacement of an electrically failed transformer, restoration of a matching Detex exit-alarm control installation, service of appropriately specified commercial security equipment, and stocked replacement inventory for facilities whose approved equipment schedules call for the 106021.
What Is Included
One Detex 106021 277VAC-to-24VAC 75VA transformer. Exit alarms, exit devices, battery eliminators, DC conversion modules, controllers, locks, wiring, circuit-protection devices, electrical enclosures and installation labor are not included unless separately specified in an order.
Important Ordering Notes
This is a 277VAC input / 24VAC output transformer, not a 120VAC-input model and not a 24VDC power supply. Detex's official parts documentation identifies the electrical rating as 277VAC to 24VAC, 75VA. Exact physical dimensions, connection arrangement, mounting requirements and certification details should be confirmed from current manufacturer documentation before installation. Work on line-voltage circuits must follow applicable electrical and life-safety requirements.