{"product_id":"detex-90-800-series-800-power-supply-24vdc-1a-regulated","title":"Detex 90-800 Series 800 Power Supply | 24VDC 1A Regulated","description":"\u003ch2\u003eDetex 90-800 Series 800 Power Supply — 24VDC, 1 Amp Continuous\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDetex 90-800\u003c\/strong\u003e is a complete, enclosed \u003cstrong\u003e24VDC filtered and regulated power supply\u003c\/strong\u003e designed for compatible commercial \u003cstrong\u003eelectrified exit devices, electric dogging, delayed egress and electromagnetic locking systems\u003c\/strong\u003e. It accepts standard \u003cstrong\u003e120VAC input\u003c\/strong\u003e and supplies \u003cstrong\u003e24VDC at 1.0 amp continuous\u003c\/strong\u003e to approved electric locking and access-control components. A built-in \u003cstrong\u003efire-alarm interface\u003c\/strong\u003e supports the release of appropriately wired fail-safe locks when required by the installation.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eAdditional Product Specifications and Ordering Guidance\u003c\/h3\u003e\n\u003ch4\u003ePower-Supply Sizing and System Compatibility\u003c\/h4\u003e\n\u003cp\u003eDetex electrical power accessories must be sized for the selected exit-device or alarm controller rather than chosen solely by their nominal voltage. The power supply's regulated current, connected loads and emergency-release requirements affect reliable door operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFactory item on this listing:\u003c\/strong\u003e DTX-90-800.\u003c\/p\u003e\n\u003ch4\u003eProduct Selection and Installation Checklist\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMatch the original power or battery-eliminator model and approved Detex host application before substituting a different version.\u003c\/li\u003e\n\u003cli\u003eCalculate combined continuous and starting currents, cabling voltage drop and the required input power source.\u003c\/li\u003e\n\u003cli\u003eReview any alarm supervision, power-loss indication, battery\/standby requirements and control-panel interfaces for the selected assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm enclosure, mounting ventilation, protective wiring, fuse ratings and field installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAcceptance and Service Verification\u003c\/h4\u003e\n\u003cp\u003eTest output under normal operating load, startup\/inrush behavior where applicable, and the host exit\/alarm system's expected power-failure response.\u003c\/p\u003e\n\u003ch4\u003eFactory Package and Related Components\u003c\/h4\u003e\n\u003cp\u003eThe specified Detex power or battery-eliminator assembly only; additional controllers, batteries, housing and wiring depend on the selected model. Consult the original model specifications below when matching the factory SKU to an existing opening.\u003c\/p\u003e\u003c\/section\u003e\n\u003cp\u003e\u003cstrong\u003eModel selection is important:\u003c\/strong\u003e The \u003cstrong\u003e90-800 provides fixed 24VDC output and does not include a battery-charging circuit or battery backup\u003c\/strong\u003e. Unlike the separate \u003cstrong\u003eDetex 80-800\u003c\/strong\u003e, it is \u003cstrong\u003enot\u003c\/strong\u003e field-selectable for 12VDC\/24VDC and does not offer the 80-800's integrated battery charger. The listed 90-800 is the standard \u003cstrong\u003e120VAC-input\u003c\/strong\u003e configuration, \u003cstrong\u003enot\u003c\/strong\u003e the optional 90-800IN input-voltage version or 90-800LT less-transformer version.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Detex Series 800 power supply:\u003c\/strong\u003e Model \u003cstrong\u003e90-800\u003c\/strong\u003e, a complete assembled power supply in a commercial-duty metal enclosure—not just a circuit board or transformer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltered, regulated 24VDC output:\u003c\/strong\u003e Stable DC power for compatible electronic door-locking hardware and access-control components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0 amp continuous output rating:\u003c\/strong\u003e The total system load must remain within Detex's rated output and applicable circuit specifications. Do not assume two terminal connections permit 2A total output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 120VAC input:\u003c\/strong\u003e Detex installation literature specifies \u003cstrong\u003e120VAC, 60Hz, 0.65A maximum\u003c\/strong\u003e for this model. Use suitable branch circuit, wiring and disconnect procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo 24VDC output terminal sets:\u003c\/strong\u003e Detex's 90-800 wiring diagram shows separately accessible positive\/negative output terminal blocks, with the supply rated \u003cstrong\u003e1 amp continuous\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-alarm loop input:\u003c\/strong\u003e Supports fail-safe lock release where the unit is correctly integrated with the building's fire alarm and approved locking system. Configure wiring for fail-safe response according to the Detex instructions and local codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED system-status indication:\u003c\/strong\u003e Visual indication assists installation checks and system troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-resetting circuit protection:\u003c\/strong\u003e Built-in protection supports reliable operation and service after an electrical fault has been corrected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService on\/off switch:\u003c\/strong\u003e Main power control supports inspection and service by qualified personnel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty 18-gauge enclosure:\u003c\/strong\u003e Protective indoor housing for electrical power-supply components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass 2 rated output:\u003c\/strong\u003e Designed for compatible commercial access-control and electrified door-hardware installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo integral battery charging:\u003c\/strong\u003e The 90-800 does \u003cstrong\u003enot\u003c\/strong\u003e include the battery-charger, low-battery-disconnect or standby backup features of the 80-800.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eDetex Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e90-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Series\u003c\/th\u003e\n\u003ctd\u003eSeries 800 Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eComplete enclosed filtered \/ regulated DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard AC Input\u003c\/th\u003e\n\u003ctd\u003e120VAC at 60Hz, 0.65A maximum per 90-800 installation instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegulated DC Output\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e24VDC fixed\u003c\/strong\u003e (not field-selectable to 12VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Output Rating\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1.0 amp\u003c\/strong\u003e (total rated supply output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Connections\u003c\/th\u003e\n\u003ctd\u003eTwo 24VDC output terminal sets shown in the Detex wiring diagram; respect the overall 1A supply rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Classification\u003c\/th\u003e\n\u003ctd\u003eClass 2 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire-Alarm Input\u003c\/th\u003e\n\u003ctd\u003eYes; provides interface for releasing approved fail-safe locks when wired as required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatus Indicator\u003c\/th\u003e\n\u003ctd\u003eLED system-status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCircuit Protection\u003c\/th\u003e\n\u003ctd\u003eAuto-resetting protection \/ individually protected output connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eHeavy-duty 18-gauge metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery-Charging Circuit\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003eNo — 90-800 does not include a battery charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Backup\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNot included\u003c\/strong\u003e; use the proper Detex 80-800 or a separately approved backup solution if standby power is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible Device Types\u003c\/th\u003e\n\u003ctd\u003eDetex-approved ED electric dogging, EE delayed egress, and EM electromagnetic locking hardware, within the model's electrical ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIndoor use only\u003c\/strong\u003e per Detex installation instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Ambient\u003c\/th\u003e\n\u003ctd\u003eDetex instructions specify 0–49°C (32–120°F); install in a suitable indoor environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Option Supplied\u003c\/th\u003e\n\u003ctd\u003eStandard 90-800 with transformer. Optional 90-800IN or 90-800LT configurations are different factory orders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetex Installation Manual\u003c\/th\u003e\n\u003ctd\u003e103158 — 90-800 Filtered and Regulated Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10 lb provisional Shopify setting\u003c\/strong\u003e based on the existing Series 800 supply listing; exact 90-800 packed weight not manufacturer-verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24VDC power for approved commercial electrified exit-device and electric dogging systems\u003c\/li\u003e\n\u003cli\u003eCompatible Detex EE delayed-egress configurations requiring a filtered, regulated 24VDC power source\u003c\/li\u003e\n\u003cli\u003eElectromagnetic locking and access-control applications with approved fire-alarm release integration\u003c\/li\u003e\n\u003cli\u003eSchools, healthcare facilities, government buildings, warehouses, retailers and commercial properties\u003c\/li\u003e\n\u003cli\u003eReplacement of a failed complete 90-800 power-supply unit where the exact manufacturer model is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e90-800 vs. 80-800 — Important Differences\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetex 90-800 (This Listing)\u003c\/th\u003e\n\u003cth\u003eDetex 80-800 (Separate Product)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulated output\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24VDC fixed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-selectable \u003cstrong\u003e12VDC or 24VDC\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.0A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.0A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNot included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIncluded\u003c\/strong\u003e, for separately purchased compatible batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire-alarm input\u003c\/td\u003e\n\u003ctd\u003eYes, for approved fail-safe locking systems\u003c\/td\u003e\n\u003ctd\u003eYes, for approved fail-safe locking systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical choice\u003c\/td\u003e\n\u003ctd\u003eFixed 24VDC system where integral battery backup is not required\u003c\/td\u003e\n\u003ctd\u003e12\/24VDC selection or an installation needing optional battery-backed power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cp\u003eOne genuine \u003cstrong\u003eDetex 90-800 assembled power-supply unit\u003c\/strong\u003e in the standard 120VAC-input configuration, including its manufacturer-specified internal power supply, transformer, fire-alarm input circuitry, and steel enclosure. Confirm the current factory packing list for mounting hardware and documentation supplied with the unit.\u003c\/p\u003e\n\u003ch3\u003eNot Included \/ Sold Separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackup batteries, battery charger or integrated battery-backup module\u003c\/li\u003e\n\u003cli\u003eOptional 240VAC input version (90-800IN) or less-transformer version (90-800LT)\u003c\/li\u003e\n\u003cli\u003eSeparate access-control readers, exit devices, maglocks, and external security controllers\u003c\/li\u003e\n\u003cli\u003eAny remote interface\/controller necessary for an electric latch-retraction or custom delayed-egress installation\u003c\/li\u003e\n\u003cli\u003eCover lock and keys, special field wiring, conduit and electrical installation materials unless explicitly specified on the factory order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cp\u003eThe Shopify shipping weight is set to \u003cstrong\u003e10 lb as a provisional estimate\u003c\/strong\u003e. Detex-packed shipment weight and outside carton dimensions for this exact 90-800 model could not be verified. Confirm actual packaged weight and carton dimensions before rating freight or UPS shipments and update the shipping profile if the distributor's shipment differs.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Electrical-Safety Notes\u003c\/h3\u003e\n\u003cp\u003eSpecify \u003cstrong\u003eDetex 90-800\u003c\/strong\u003e for \u003cstrong\u003e120VAC-input to 24VDC \/ 1.0A continuous power\u003c\/strong\u003e. Confirm the total connected load, voltage, wiring length, fail-safe fire-alarm interface, emergency egress requirements, and compatibility with the exact electric locking product. \u003cstrong\u003eDo not substitute this model for the 80-800 where battery-backed operation or field-selectable 12V output is required.\u003c\/strong\u003e The 90-800 is intended for indoor use only. All high-voltage wiring and fire-alarm interconnection must be performed by qualified personnel with power disconnected, following the current Detex 103158 instructions, applicable electrical and life-safety codes, and the authority having jurisdiction.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":68054790111447,"sku":"DTX-90-800","price":521.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/DETEX_90-800.png?v=1794516339","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-90-800-series-800-power-supply-24vdc-1a-regulated","provider":"Commercial Door Worx","version":"1.0","type":"link"}