- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex Advantex F10 Fire-Rated Rim Exit | 36 or 48 in
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex Advantex F10 Fire-Rated Rim Exit | 36 or 48 in
Detex Advantex F10 Fire-Rated Rim Exit | 36 or 48 in
$2,633.00
$1,621.93
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
The Detex Advantex F10 Series fire-rated rim exit devices provide panic-style egress hardware for correctly specified and listed fire-door openings. This listing offers two distinct factory arrangements in 630 / US32D satin stainless steel with a 99 surface rim strike: a 36-inch F10 LD less-dogging model without the factory EA exit alarm, and a 48-inch F10 EA LD model with the factory audible EA exit-alarm function.
Fire-door requirement: Both variants use less-dogging/no-dogging construction for the approved fire-exit function. Do not add or engage mechanical dogging on a labeled fire exit. The EA alarm in the 48-inch model provides signaling but does not intentionally delay release.
Manufacturer Configurations
| Selectable Option | Detex SKU |
|---|---|
| 36 in / Fire-Rated LD / No Exit Alarm | DTX-F10-LD-630-99-36 |
| 48 in / Fire-Rated EA Alarm + LD | DTX-F10-EA-LD-630-99-48 |
Key Features and Applications
- Advantex F10 fire-exit hardware for appropriately approved labeled door assemblies
- Less-dogging construction on both listed factory models
- 36-inch standard mechanical F10 LD and 48-inch F10 EA LD exit-alarm option
- 630 satin stainless finish and specified 99 surface strike
Ordering and Installation Checklist
- Confirm the approved fire-door label, compatible frame/strike, fire-exit listing and hardware-schedule requirements.
- Match the door width and the complete model code; do not assume the alarm is included with the 36-inch LD device.
- For the 48-inch EA model, verify the alarm power, arming and reset requirements along with any required monitoring connections.
- Verify secure relatching, self-closing operation, unrestricted egress and alarm function where equipped.
Package Contents
One factory Detex exit-device assembly selected by the exact model number. Confirm included strike, mounting hardware, trim, cylinder/keys and electronic accessories against the factory kit. Separate controllers, external power sources, door/frame, unrelated parts and installation labor are not included unless documented for that SKU.
Detailed Manufacturer-Specific Model Descriptions
36 in / Fire-Rated LD / No Exit Alarm — DTX-F10-LD-630-99-36
The Detex Advantex F10 LD 630 99 36 is a super-heavy-duty ANSI/BHMA A156.3 Grade 1 fire-rated rim exit device engineered for 36-inch-wide (3-foot) commercial fire doors. This genuine Detex F10 Series wide-stile fire exit hardware includes the required LD less/no dogging configuration, No. 99 surface-mounted rim strike, and 630 / US32D satin stainless steel finish. Its robust mechanical pushpad provides quick, unobstructed egress while allowing the door to close and latch positively after use, as required by the rated opening design.
Three-Hour Fire-Exit Hardware: The Detex F10 platform is UL 10C listed for up to 3-hour fire-door assemblies when specified and installed with the appropriate listed door, frame, strike, fasteners and, where applicable, Detex-approved fire-rated center mullion. Detex publishes applications including up to 4 ft × 10 ft single doors and up to 8 ft × 8 ft pairs with an approved F90KR keyed removable mullion. The exact permitted rating and installation depend on the complete door assembly and adopted local codes. Fire-exit hardware is not a substitute for a labeled fire door, closer, correct frame or compliant opening.
Additional Product Specifications and Ordering Guidance
Exit Device Configuration, Hardware Schedule and Service
Detex exit devices must be selected for the complete opening and the intended mechanical, alarm or electrically controlled function. Rim, surface-vertical-rod and top-rod devices have different strike and door/frame preparation; the full factory SKU controls compatibility.
Factory item on this listing: DTX-F10-LD-630-99-36.
Product Selection and Installation Checklist
- Confirm door width, height, handing, stile and the designated Detex series and device length.
- Match the panic/exit device's latch and strike layout, outside trim, finish and required mechanical dogging state.
- Review the approved hardware schedule for fire-rated, windstorm, weatherized, alarmed, delayed-egress or electric-latch-retraction requirements.
- Identify any separate power supply, access-control interface, key cylinder, required mullion or outside trim needed for complete use.
- For labeled fire exits, retain the complete listed assembly, certified mounting and latching configuration, fire-door-compatible strike and required no-dogging behavior.
Acceptance and Service Verification
Check smooth latch engagement, free mechanical emergency exit, authorized dogging and any alarm, electrical release, automatic-door or reset sequences specified for the exact factory model.
Factory Package and Related Components
The selected exit-device assembly and components stated for its factory SKU. Separate controllers, readers, facility keys, field wiring and installation are not automatically included. Consult the original model specifications below when matching the factory SKU to an existing opening.
LD Less Dogging – Positive Latching: The LD designation means no mechanical dogging feature. Unlike Detex 10 HD (hex dogging) or 10 CD (cylinder dogging), this fire-exit device cannot hold the pushpad and latch retracted for daytime passage. The stainless steel deadlocking Pullman-style rim latch remains able to re-engage after every exit, maintaining the intended positive-latching behavior of a fire-door assembly. Never add an aftermarket dogging kit or substitute a doggable panic device where listed fire-exit hardware is required.
36-Inch Wide-Stile Rim Configuration: The 36 model is designed for compatible 36-inch door widths. Its surface-mounted rim latch engages the No. 99 surface-mounted strike on a properly prepared frame or an approved removable mullion. The device is non-handed and field-sizeable according to Detex instructions and is intended for commercial doors meeting the specified mounting clearances, typically with a minimum 4-5/8-inch stile for the 99 strike and a 1-3/4-inch to 2-1/4-inch door thickness. Verify actual door preparations using the current Detex template.
630 Satin Stainless Steel: The ordered 630 / US32D finish offers a brushed satin stainless steel architectural appearance suited to heavy-traffic institutions and commercial facilities. Detex uses a durable PVD finishing process over stainless steel exposed surfaces on its Advantex hardware. A stainless deadlocking Pullman latchbolt, heavy-duty EC1 angled/ramped end cap, and the proprietary mounting plate with strike locator support security, durability and correct installation.
Exit-Only, Mechanical Hardware: This part number does not include exterior lever trim, pull trim, rim cylinder, alarm, batteries, electrical latch retraction, delayed egress, request-to-exit switch or power supply. It is a purely mechanical fire-exit rim device, not an F10 EA alarm model. If outside entry is required, choose separately specified Detex F10-compatible and approved outside trim and required cylinders/keying without modifying the fire-exit listing.
Key Features and Benefits
- Detex Advantex F10 Series: Genuine super-heavy-duty wide-stile rim fire-exit device for high-use commercial and institutional fire doors.
- Grade 1 fire exit hardware: Built to ANSI/BHMA A156.3 Grade 1 mechanical exit requirements and Detex's fire-exit listings.
- Up to 3-hour UL 10C listing: Designed for properly specified fire-door assemblies subject to all opening and hardware listing conditions.
- 36-inch nominal device size: Designed for compatible 3-foot-wide doors; field sizing only under Detex's instructions.
- LD less/no dogging: No dogging hole, hex mechanism or mortise dogging cylinder on the ordered fire-exit configuration.
- Positive fire-door latching: Deadlocking Pullman-style stainless steel rim latch engages when the door closes.
- Detex No. 99 surface-mounted strike: Proper rim-strike hardware for the ordered F10 fire-exit model.
- 630 / US32D satin stainless finish: Durable brushed stainless architectural appearance suitable for demanding commercial facilities.
- Stainless steel construction: Heavy-duty stainless components and PVD surface finishing resist routine commercial abuse.
- Patented mounting plate: Designed for straightforward installation and accurate positioning of the rim device.
- Detex strike locator: Simplifies correct alignment of latch and No. 99 surface strike.
- EC1 angled heavy-duty endcap: Deflects accidental impacts from carts, deliveries and facility equipment.
- Non-handed exit device: Compatible with the approved right- and left-hand reverse swinging door preparations.
- Field-sizeable according to instructions: Accommodates allowed size adjustments while preserving assembly compliance.
- High-cycle Advantex platform: Detex reports testing the 10 Series beyond one million operations for demanding service.
- Fire-rated single doors: Use on correctly labeled, compatible 36-inch single fire-door openings.
- Fire-rated pairs with approved mullion: Pairs must use an approved labeled door assembly and factory-authorized mullion, such as compatible F90KR.
- Mechanical emergency egress: No electrical power, batteries, controller or alarm activation required for the pushpad to release the latch.
- No exterior trim included: Complete exit-only interior device; select compatible outside pull or keyed trim separately if needed.
- Manufacturer support: Subject to the current Detex limited mechanical warranty and authorized installation requirements.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Product Line | Advantex F10 / Fire-Rated 10 Series Wide-Stile Rim |
| Manufacturer Model | F10 LD 630 99 36 |
| Shopify SKU | DTX-F10-LD-630-99-36 |
| Hardware Type | Fire-rated Grade 1 mechanical rim exit device, exit only |
| Nominal Door Width | 36 inches / 3 feet |
| Exit Device Size | 36-inch nominal door-width configuration; overall device body is shorter than nominal door width |
| Fire Listing | UL 10C, up to 3 hours on properly listed and installed fire-door assemblies |
| Fire-Door Applications | Manufacturer publishes up to 4 ft × 10 ft single doors, or pairs up to 8 ft × 8 ft with approved F90KR mullion, subject to listing |
| Dogging Option | LD – less/no dogging, for continued positive fire-door latching |
| Hex Dogging | None – not HD |
| Cylinder Dogging | None – not CD; no dogging cylinder required |
| Rim Strike | Detex No. 99 surface-mounted strike |
| Finish | 630 / US32D satin/brushed stainless steel |
| Latchbolt | Stainless steel deadlocking Pullman-type rim latchbolt |
| Handing | Non-handed exit hardware |
| Minimum Door Stile | 4-5/8 inches with Detex No. 99 strike, subject to current template |
| Door Thickness | Typically 1-3/4 inches to 2-1/4 inches; verify special applications |
| Device Grade | ANSI/BHMA A156.3 Grade 1 |
| Accessibility | Detex F10 platform meets applicable ADA/A117.1 operating hardware criteria when correctly installed |
| Endcap | EC1 heavy-duty angled/ramped end cap |
| Mounting Hardware | Manufacturer-standard mounting system with patented mounting plate and strike locator |
| Exterior Trim | None – no outside lever, pull or keyed entry trim |
| Electrical Functions | None – no EA, EB-W, EE, ER, EX or electrical power supply |
| Weatherized Option | Not specified; do not classify as a weatherized F10xW model |
| Approved Pairing | Only with listed door/frame configuration and compatible fire-rated mullion when required |
| Shipping Weight | 18 lb estimated for carton and complete 36-inch device; verify actual packaged weight before fulfillment |
| Warranty | Current Detex limited mechanical warranty terms, generally 10 years for qualified mechanical devices |
Typical Commercial Applications
- 36-inch fire-rated steel doors in schools, colleges, hospitals, senior living facilities and healthcare facilities
- Commercial offices, government buildings, airports, warehouses and industrial sites requiring rated fire-exit hardware
- High-use public building corridors with fire doors that must close and latch positively
- Single fire-door leaves and approved paired fire-door assemblies with a correctly listed center mullion
- Replacement Detex F10 fire-exit hardware where existing frame preparation and strike match the 99 surface strike
- Commercial door schedules specifying a non-handed 630 stainless steel fire-rated rim exit device without alarms or dogging
Included in the Standard Assembly
One Detex Advantex F10 36-inch fire-rated rim exit device with LD less-dogging configuration, stainless deadlocking rim latch, No. 99 surface-mounted strike, 630 satin stainless steel finish, heavy-duty end cap and manufacturer-standard mounting hardware. Verify current Detex packing contents and any factory-selected mounting accessories against the packing list.
Not Included
Outside lever, pull, keyed cylinder or exterior escutcheon trim, fire-rated removable center mullion, door, frame, closer, seals, wiring, electrical alarm equipment, power supply, installation labor and special mounting accessories are not included unless separately specified. No dogging mechanism, dogging cylinder or alarm is part of this F10 LD configuration.
Fire-Door Ordering and Installation Notes
Part number: F10 = fire-rated Advantex 10 Series wide-stile rim device; LD = less/no dogging; 630 = satin stainless steel; 99 = rim surface strike; 36 = nominal 3-foot door. Before purchase, verify the entire fire-door and frame label, UL 10C assembly listing, closing and positive-latching requirements, No. 99 strike preparation, approved F90KR or equivalent factory-approved mullion on pairs, accessibility, frame/door thickness, clearances, and local AHJ requirements. Follow Detex's current hardware templates and NFPA 80 requirements. Do not add mechanical dogging, substitute a panic-only device, or install unapproved outside trim on a fire door. The 18 lb shipping weight is an estimate and must be replaced with the actual packed carrier weight when available.
48 in / Fire-Rated EA Alarm + LD — DTX-F10-EA-LD-630-99-48
The Detex Advantex F10 EA LD 630 99 48 is a super-heavy-duty, ANSI/BHMA A156.3 Grade 1, fire-rated wide-stile rim exit device combining 48-inch nominal fire-exit hardware, an integrated EA audible exit alarm, LD less dogging, a Detex No. 99 surface-mounted rim strike, and 630 / US32D brushed satin stainless steel finish. Designed for properly prepared 48-inch / 4-foot-wide commercial fire doors, the F10 Series combines durable, positive mechanical latching with a local audible alarm that notifies personnel when someone attempts an unauthorized exit.
F10 Fire-Rated Exit Device: The F designation specifies Detex's 3-hour UL 10C listed fire exit hardware configuration within its approved fire door assemblies, subject to the correct door, frame, strike, fasteners and any required mullion. It is not a standard 10 Series panic device. Fire doors must retain positive latching and cannot use mechanical dogging to hold the latch retracted. For that reason this model includes LD – less/no dogging rather than HD hex dogging or CD cylinder dogging. This distinction is essential for fire-rated doors and must be preserved during installation and maintenance.
Additional Product Specifications and Ordering Guidance
Exit Device Configuration, Hardware Schedule and Service
Detex exit devices must be selected for the complete opening and the intended mechanical, alarm or electrically controlled function. Rim, surface-vertical-rod and top-rod devices have different strike and door/frame preparation; the full factory SKU controls compatibility.
Factory item on this listing: DTX-F10-EA-LD-630-99-48.
Product Selection and Installation Checklist
- Confirm door width, height, handing, stile and the designated Detex series and device length.
- Match the panic/exit device's latch and strike layout, outside trim, finish and required mechanical dogging state.
- Review the approved hardware schedule for fire-rated, windstorm, weatherized, alarmed, delayed-egress or electric-latch-retraction requirements.
- Identify any separate power supply, access-control interface, key cylinder, required mullion or outside trim needed for complete use.
- For labeled fire exits, retain the complete listed assembly, certified mounting and latching configuration, fire-door-compatible strike and required no-dogging behavior.
- EA hardwired alarms, EB battery alarms and EB-W weatherized battery alarms have distinct power and control requirements; select by the specified factory code.
Acceptance and Service Verification
Check smooth latch engagement, free mechanical emergency exit, authorized dogging and any alarm, electrical release, automatic-door or reset sequences specified for the exact factory model.
Factory Package and Related Components
The selected exit-device assembly and components stated for its factory SKU. Separate controllers, readers, facility keys, field wiring and installation are not automatically included. Consult the original model specifications below when matching the factory SKU to an existing opening.
EA Alarm – Immediate Egress, Audible Security: The EA option adds a monitored pushpad switch and an approximately 100 dB piezo audible alarm. When the alarm is armed, pressing the exit pushpad generates a local alert and can send a remote alarm signal to compatible security equipment. The EA assembly supports remote alarm relay signaling, remote bypass, audible/visual arming indicators, status LEDs, and audible/visual low-battery notification. This is an exit-alarm device, NOT an EE delayed-egress device. The alarm does not impose a 15-second lock-release delay or prevent immediate mechanical egress through the listed fire-exit hardware.
Arming Timing and Alarm Control: Detex's standard EA electronics use a factory-default 15-second alarm arming delay after a key reset (1- or 5-second alternative settings available from the factory) and offer manual key arming or a field-selectable 2-minute automatic rearm mode. The 15-second setting concerns the alarm's armed status, not the time a person must wait to leave. Optional factory settings permit other rearming intervals. When properly configured and installed, a compatible security system may bypass the alarm for authorized entry or exit without disabling code-required free egress.
Power Options: The EA alarm is designed for a standard 9V battery or optional 12V/24V AC/DC external power with 9V battery backup. The standard EA arrangement provides battery-powered standalone alarming. A separate transformer, conduit kit, electrical hinge or power-transfer accessory should not be assumed included for the model as listed; select additional components based on the actual site wiring and factory packing list. Approved electrical wiring, batteries and alarm interfaces must follow current Detex installation instructions.
Mortise Cylinder for EA Arming – No Dogging: The exit-alarm key switch uses a compatible mortise cylinder with standard Yale cam to arm, disarm or reset the alarm. The cylinder is sold separately unless a factory-installed cylinder is explicitly ordered. Because this is an F10 LD fire-rated assembly, the arming cylinder does NOT dog the pushpad or hold the latch retracted. Do not describe this model as cylinder dogging or install dogging parts on it. LD means no mechanical dogging feature.
Exit-Only, No Outside Entry Trim: The manufacturer code F10 EA LD 630 99 48 does not specify an exterior lever, pull, key-retracting trim, blank exterior escutcheon, exterior cylinder or a removable center mullion. The ordered item is the interior fire-exit rim device with EA alarm and 99 strike. Any outside entry trim must be separately approved for the F10 rated fire-door application. Additional keying and installation preparations are sold separately.
Key Features and Benefits
- Detex Advantex F10 fire exit hardware: Fire-rated configuration of the super-heavy-duty Grade 1 10 Series wide-stile rim exit device.
- 3-hour fire-exit hardware listing: F10 platform has UL 10C listing for applicable fire-door assemblies; the complete door opening and chosen mullion must match the listing.
- 48-inch nominal size: Designed for appropriately prepared commercial fire doors up to 4 feet wide.
- LD less dogging: No hex or cylinder dogging mechanism; positively latching fire exit hardware is required for rated doors.
- EA audible alarm: Approximately 100 dB alarm notifies facility personnel when the armed interior touchpad is depressed.
- Free mechanical egress: The pushpad releases the latch promptly even when the alarm is armed; not a delayed-egress electrical lock.
- Mortise-cylinder key arming: Compatible standard-Yale-cam mortise cylinder operates EA arming/disarming/reset; cylinder sold separately, no dogging function.
- 9V alarm operation: Supports standard battery use or appropriately specified 12/24V AC/DC supply with battery backup.
- Visual and audible status: Green/red arming indication, status feedback and low-battery alert support routine inspections.
- Remote alarm contacts: Alarm relay contacts support connection to compatible monitoring or remote annunciation systems.
- Remote bypass input: Can be connected to authorized external controls where permitted and properly wired.
- 15-second alarm-arming interval: Standard factory setting after key reset, distinct from any restriction on egress.
- Selectable rearming: Manual key arming or approximately 2-minute automatic rearming per factory/field setup.
- Detex No. 99 surface-mounted rim strike: Standard F10 Series strike for properly prepared frame or approved fire-rated mullion.
- 630 / US32D brushed stainless: Satin stainless steel architectural finish, with PVD treatment on exposed stainless surfaces.
- Deadlocking stainless Pullman rim latch: Reliable positive engagement when the device closes and latches.
- ANSI/BHMA A156.3 Grade 1: Built for frequent use in schools, medical institutions, public facilities and heavy-use commercial sites.
- Non-handed, field-sizeable hardware: Device mounting and allowable cutting must follow manufacturer's current instructions.
- Patented mounting plate and strike locator: Helps the installer accurately position the device and strike.
- EC1 heavy-duty angled endcap: Deflects incidental impacts from carts and equipment.
- Exterior entry trim sold separately: Specify Detex-approved fire-rated outside trim for any outside-entry requirement.
- Standard alarm signage: EA alarm package is typically furnished with an EA-561 alarm warning sign; confirm exact factory package and project-specific signage.
- Manufacturer limited warranty: Detex limited warranty terms apply; typical 10-year mechanical / 3-year electrical coverages subject to current conditions.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Product Series | Advantex F10 / 10 Series Wide-Stile Rim Fire Exit |
| Manufacturer Model | F10 EA LD 630 99 48 |
| Shopify SKU | DTX-F10-EA-LD-630-99-48 |
| Hardware Type | Grade 1 fire-rated wide-stile rim exit device with integrated alarm |
| Nominal Door Width | 48 inches / 4 feet |
| Fire Exit Listing | F10, UL 10C, up to 3 hours within manufacturer-listed fire door assemblies |
| Dogging | LD – Less/No Dogging; no mechanical dogging permitted on this fire-exit configuration |
| Alarm Option | EA – stand-alone local electronic exit alarm |
| Alarm Sound | Approximately 100 dB piezo horn |
| Alarm Trigger | Monitored pushpad activation when armed |
| Standard Alarm Power | 9-volt battery; or external 12V/24V AC/DC with 9V backup |
| External Transformer / Power Transfer | Not assumed included; optional accessories sold separately as required |
| Alarm Arming Delay | Factory default 15 seconds after key reset; NOT an egress-release delay |
| Alarm Rearming | Manual key arming or field-selectable approx. 2-minute automatic rearm |
| Remote Alarm Output | Remote alarm relay signaling for compatible security/monitoring inputs |
| Remote Bypass | Remote bypass input, for authorized external controls |
| Alarm Indicators | Audible/visual arming, status LEDs, audible/visual low-battery alert |
| Key Cylinder | Compatible mortise cylinder with standard Yale cam, for alarm arming/disarming; sold separately unless factory specified |
| Cylinder Dogging? | No – LD fire-exit configuration has no dogging, regardless of alarm key switch |
| Hex Dogging? | No – fire-rated LD is not HD |
| Delayed Egress? | No – EA alerts but does not delay mechanical exit |
| Strike | Detex No. 99 surface-mounted rim strike |
| Finish | 630 / US32D brushed / satin stainless steel |
| Rim Latch | Stainless steel deadlocking Pullman-style latchbolt |
| Handing | Non-handed rim exit device |
| Door Thickness | Standard approximately 1-3/4 to 2-1/4 inches; confirm Detex template |
| Minimum Stile with Strike 99 | 4-5/8 inches, subject to manufacturer door preparation |
| Mounting | Patented Detex mounting plate and strike locator; heavy-duty EC1 angled endcap |
| Outside Entry Trim | None included; factory-compatible F10 trim selected separately if necessary |
| Fire-Rated Pair Applications | Follow specific Detex-approved F-series mullion and compatible door assembly listing |
| Weatherized Option | None specified; do not assume exterior weatherized alarm components |
| Shipping Weight | 23 lb estimated including 48-inch device, alarm and packaging; verify actual carton weight |
| Warranty | Detex limited manufacturer mechanical and electrical warranty conditions |
Commercial Applications
- Fire-rated egress doors in schools, universities, hospitals, senior care buildings and government facilities
- 48-inch commercial fire doors requiring an audible warning when the armed emergency exit is used
- High-traffic industrial, retail and institutional fire exit openings where maintenance of positive latching is essential
- Rated single doors, or approved fire-rated paired doors with compatible factory-listed mullion
- Door schedules calling for super-heavy-duty 630 stainless fire-exit hardware and an EA exit-alarm module
What's Included
One Detex Advantex F10 48-inch rim fire exit device with EA exit-alarm module, LD less-dogging (no dogging), Detex No. 99 surface rim strike, 630 satin stainless finish, deadlocking rim latch and standard factory mounting hardware. Standard EA package normally includes a 9V battery and the EA-561 alarm warning sign. Verify current shipment components, battery condition, and alarm signage before installation.
Not Included Unless Specifically Specified
Mortise cylinder for alarm arming, factory-installed cylinder option, outside lever/pull trim, keyed exterior access, approved fire-rated center mullion, optional external electrical transformer, conduit/power transfer, other remote alarm equipment, door, frame, specialty mounting materials and installation labor are not included unless separately ordered. No dogging mechanism or dogging cylinder is part of this F10 LD fire-rated hardware.
Fire-Door Installation and Ordering Notes
Model code: F10 = Advantex 10 Series 3-hour fire-exit rim hardware; EA = electronically monitored exit alarm; LD = less/no dogging; 630 = brushed satin stainless steel; 99 = surface-mounted rim strike; 48 = nominal 48-inch door-width model. For a fire-rated opening, confirm the door/frame label, accepted strike and mullion, listed installation, fasteners, closing/latching performance, accessible operating force, NFPA 80 inspection requirements, and current local fire/life-safety approvals. Never add mechanical dogging to this fire-exit device. Confirm the compatible mortise cylinder for EA arming, applicable alarm reset/bypass procedure, optional power supply, and desired outside entry trim separately. The alarm's 15-second arming delay must never be confused with delayed egress. The 23 lb shipping weight is an estimate; verify actual packed weight for carrier service before shipping.
Recently viewed products
Describe your recently viewed products here