{"product_id":"detex-be-961-1-battery-eliminator-120vac-to-9vdc-with-10-ft-conduit","title":"Detex BE-961 Battery Eliminator | Standard or 95 dB Supervised Alarm","description":"\u003ch2\u003eDetex BE-961 Battery Eliminator | 120VAC to 9VDC | Standard or Supervised 95 dB Alarm\u003c\/h2\u003e\n\u003cp\u003eReduce routine 9-volt battery replacement at compatible commercial security doors with the \u003cstrong\u003eDetex BE-961 Series Battery Eliminator\u003c\/strong\u003e. These compact wall-mount battery-eliminator assemblies convert building \u003cstrong\u003e120VAC power\u003c\/strong\u003e using an included \u003cstrong\u003e120VAC-to-12VAC external transformer\u003c\/strong\u003e, then produce the specified low-voltage DC power for compatible \u003cstrong\u003e9V Detex security devices\u003c\/strong\u003e. Both configurations include an approximately \u003cstrong\u003e10-foot flexible armored connection conduit\u003c\/strong\u003e, LED power-status indication and a cast-aluminum enclosure.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eAdditional Product Specifications and Ordering Guidance\u003c\/h3\u003e\n\u003ch4\u003ePower-Supply Sizing and System Compatibility\u003c\/h4\u003e\n\u003cp\u003eDetex electrical power accessories must be sized for the selected exit-device or alarm controller rather than chosen solely by their nominal voltage. The power supply's regulated current, connected loads and emergency-release requirements affect reliable door operation.\u003c\/p\u003e\n\u003ch4\u003eModel and Option Identification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAvailable Configuration\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Eliminator Model: BE-961-1 - Standard (No Supervisory Alarm)\u003c\/td\u003e\n\u003ctd\u003eDTX-BE-961-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Eliminator Model: BE-961-2 - Supervised (95 dB Alarm, ECL Only)\u003c\/td\u003e\n\u003ctd\u003eDTX-BE-961-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProduct Selection and Installation Checklist\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMatch the original power or battery-eliminator model and approved Detex host application before substituting a different version.\u003c\/li\u003e\n\u003cli\u003eCalculate combined continuous and starting currents, cabling voltage drop and the required input power source.\u003c\/li\u003e\n\u003cli\u003eReview any alarm supervision, power-loss indication, battery\/standby requirements and control-panel interfaces for the selected assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm enclosure, mounting ventilation, protective wiring, fuse ratings and field installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAcceptance and Service Verification\u003c\/h4\u003e\n\u003cp\u003eTest output under normal operating load, startup\/inrush behavior where applicable, and the host exit\/alarm system's expected power-failure response.\u003c\/p\u003e\n\u003ch4\u003eFactory Package and Related Components\u003c\/h4\u003e\n\u003cp\u003eThe specified Detex power or battery-eliminator assembly only; additional controllers, batteries, housing and wiring depend on the selected model. Consult the original model specifications below when matching the factory SKU to an existing opening.\u003c\/p\u003e\u003c\/section\u003e\n\u003cp\u003e\u003cstrong\u003eSelect the correct model before ordering:\u003c\/strong\u003e \u003cstrong\u003eBE-961-1\u003c\/strong\u003e is the \u003cstrong\u003estandard battery eliminator without an internal supervisory alarm\u003c\/strong\u003e for manufacturer-approved \u003cstrong\u003eDetex ECL, V40\/V50 EB and EAX 9V devices\u003c\/strong\u003e. \u003cstrong\u003eBE-961-2\u003c\/strong\u003e adds a \u003cstrong\u003esupervised power loop and built-in approximately 95 dB alarm\u003c\/strong\u003e that sounds if the protected power-feed wires are cut or the connected ECL alarm activates. Detex specifies \u003cstrong\u003eBE-961-2 for ECL-230 and ECL-600 family exit-control locks only — not V40 or EAX alarm devices\u003c\/strong\u003e. Neither model is a battery-backup charger or a complete exit locking system.\u003c\/p\u003e\n\u003ch3\u003eCompare the Available BE-961 Models\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel \/ Shopify SKU\u003c\/th\u003e\n\u003cth\u003eFunction and Compatibility\u003c\/th\u003e\n\u003cth\u003ePackage and Shipping\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBE-961-1 — Standard Battery Eliminator\u003c\/strong\u003e\u003cp\u003eSKU DTX-BE-961-1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBasic AC-powered 9VDC battery eliminator without a dedicated 95 dB supervision alarm.\u003c\/strong\u003e Use only with supported Detex \u003cstrong\u003eECL-230D, ECL-230X, ECL-600\u003c\/strong\u003e exit-control locks and manufacturer-approved \u003cstrong\u003eV40 EB\/EB-W, V50 EB\/EB-W, EAX-300 or EAX-500\u003c\/strong\u003e configurations. Up to \u003cstrong\u003ethree appropriately rated 9V devices\u003c\/strong\u003e, subject to the combined 0.5A limit and wiring requirements.\u003c\/td\u003e\n\u003ctd\u003e120VAC-to-12VAC external transformer, 10-ft flex armored conduit, power-status LED and cast-aluminum case. \u003cstrong\u003e3 lb distributor-listed shipping weight\u003c\/strong\u003e; approximately \u003cstrong\u003e10 × 7 × 5 in.\u003c\/strong\u003e packed carton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBE-961-2 — Supervised Power Loop + 95 dB Alarm\u003c\/strong\u003e\u003cp\u003eSKU DTX-BE-961-2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSupervisory-loop battery eliminator with an internal 95 dB audible alarm.\u003c\/strong\u003e The alarm sounds if the secure 9V power-feed wires are cut or the ECL unit alarms. \u003cstrong\u003eApproved Detex application: ECL-230 and ECL-600 series exit-control locks only.\u003c\/strong\u003e \u003cstrong\u003eDo not specify for V40\/V50 EB or EAX exit alarms.\u003c\/strong\u003e Verify the approved number of connected ECL locks and their total current draw for this supervised installation.\u003c\/td\u003e\n\u003ctd\u003e120VAC-to-12VAC external transformer, 10-ft flex armored conduit, integrated supervisory-loop\/alarm circuit, LED and cast-aluminum case. \u003cstrong\u003e3 lb distributor-listed shipping weight\u003c\/strong\u003e; approximately \u003cstrong\u003e10 × 7 × 5 in.\u003c\/strong\u003e packed carton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering warning:\u003c\/strong\u003e The models are not functionally interchangeable. If the application needs the \u003cstrong\u003eBE-961-2 secure power-feed alarm\u003c\/strong\u003e, choose the supervised model. If the equipment is a \u003cstrong\u003eV40 EB, V50 EB or EAX\u003c\/strong\u003e alarm, choose the \u003cstrong\u003eBE-961-1\u003c\/strong\u003e only when compatible with the precise device version and Detex's current wiring instructions. A listing elsewhere describing BE-961-2 for V40 devices does not override Detex's ECL-only restriction.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetex OEM battery eliminator:\u003c\/strong\u003e Manufacturer-designed battery-replacement power source for specified security door equipment, reducing routine disposable 9V battery changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 120VAC building supply:\u003c\/strong\u003e Both versions include an appropriate external transformer, specified as \u003cstrong\u003e120VAC input \/ 12VAC secondary\u003c\/strong\u003e, feeding the conversion board's regulated low-voltage output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9VDC device power:\u003c\/strong\u003e Power source for properly specified battery-operated Detex security equipment; confirm jumper settings and per-device voltage before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised alarm choice:\u003c\/strong\u003e The \u003cstrong\u003eBE-961-2\u003c\/strong\u003e monitors the secure power-feed loop and provides a built-in approximately \u003cstrong\u003e95 dB audible alarm\u003c\/strong\u003e in response to a cut line or connected ECL alarm. The \u003cstrong\u003eBE-961-1 does not provide this feature\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECL-only BE-961-2 compatibility:\u003c\/strong\u003e Detex limits the supervised 961-2 model to compatible \u003cstrong\u003eECL-230 and ECL-600\u003c\/strong\u003e series exit-control locks, not the V40, V50 or EAX alarm lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad BE-961-1 compatibility:\u003c\/strong\u003e The standard 961-1 can power certain approved ECL, V40 EB, V50 EB and EAX devices that use compatible 9V power; verify exact versions and technical requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.5A maximum output capacity:\u003c\/strong\u003e The Detex BE-961 series technical literature specifies \u003cstrong\u003e0.5 amp\u003c\/strong\u003e current-output capacity. Never exceed the combined rating or device-specific wiring limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to three supported 9V devices:\u003c\/strong\u003e The manufacturer advertises up to three compatible ECLs or three EB devices for the standard BE-961-1. For BE-961-2, connect only the supported ECL locks and follow the supervised-loop loading\/wiring instructions; never assume compatibility solely from the total number of devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10-foot flexible armored conduit included:\u003c\/strong\u003e Low-voltage connection may run between the wall-mount eliminator enclosure and the door security device, with an approved mounting and transfer method that will not obstruct operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED power-status indicator:\u003c\/strong\u003e Helps maintenance technicians check energized power at the eliminator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact standard cast-aluminum enclosure:\u003c\/strong\u003e Nominal dimensions \u003cstrong\u003e4-5\/8 × 4-5\/8 × 2 inches\u003c\/strong\u003e excluding conduit and external transformer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput transient suppression:\u003c\/strong\u003e Manufacturer-described electrical protection for normal building-power disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial installation:\u003c\/strong\u003e Suited to stores, institutional facilities, warehouses, schools and other approved indoor installations with compatible Detex alarms or ECL exit-control locks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetex limited warranty:\u003c\/strong\u003e BE-961 product literature identifies a \u003cstrong\u003ethree-year limited manufacturer's warranty\u003c\/strong\u003e, subject to current terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eDetex Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Family\u003c\/th\u003e\n\u003ctd\u003eBE-961 Series Battery Eliminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModels Offered\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBE-961-1\u003c\/strong\u003e standard \/ \u003cstrong\u003eBE-961-2\u003c\/strong\u003e ECL-supervised with internal 95 dB alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eEnclosed commercial-door battery eliminator \/ 9V device power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilding Power Input\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e120VAC\u003c\/strong\u003e, fed through included external transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransformer\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e120VAC to 12VAC\u003c\/strong\u003e transformer included with BE-961-1 and BE-961-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Output\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e9VDC\u003c\/strong\u003e specified application, with manufacturer-directed jumper settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Current Output\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e0.5 amp\u003c\/strong\u003e, combined maximum per Detex technical documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-1 Alarm Supervision\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003eNo built-in supervisory cut-wire alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-2 Alarm Supervision\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSecure power-feed supervisory loop\u003c\/strong\u003e with internal approximately \u003cstrong\u003e95 dB\u003c\/strong\u003e alarm for cut wires or connected ECL unit alarm event\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-1 Supported Equipment\u003c\/th\u003e\n\u003ctd\u003eApproved Detex ECL-230D \/ ECL-230X \/ ECL-600, V40 EB \/ EB-W, V50 EB \/ EB-W, EAX-300 \/ EAX-500; verify the exact manufacturer's device and wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-2 Supported Equipment\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDetex ECL-230 \/ ECL-600 family only\u003c\/strong\u003e, per manufacturer. \u003cstrong\u003eNot for V40 \/ EAX\u003c\/strong\u003e; verify all proposed connections in the current ECL and BE-961 manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Flexible Conduit\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e10 ft armored flexible connecting conduit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatus Indicator\u003c\/th\u003e\n\u003ctd\u003eLED visual power-status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eCast-aluminum wall-mount enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing Dimensions\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e4-5\/8 in wide × 4-5\/8 in high × 2 in deep\u003c\/strong\u003e (not outer shipping carton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Protection\u003c\/th\u003e\n\u003ctd\u003eManufacturer-standard line-input transient suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Charger or Backup\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNone included\u003c\/strong\u003e. Requires compatible utility power; does not itself furnish battery-backed standby operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeatherized Enclosure\u003c\/th\u003e\n\u003ctd\u003eNo; the standard model is not the \u003cstrong\u003e106595-5 NEMA weatherized\u003c\/strong\u003e battery eliminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Instructions\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e101320\u003c\/strong\u003e — Detex BE-961 Battery Eliminator Installation Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eManufacturer's three-year limited warranty, subject to current conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-1 Shipping Weight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3 lb\u003c\/strong\u003e, distributor-listed package weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBE-961-2 Shipping Weight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3 lb\u003c\/strong\u003e, distributor-listed package weight; another retailer may quote differently depending on packed method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDistributor Carton Size\u003c\/th\u003e\n\u003ctd\u003eApproximately \u003cstrong\u003e10 × 7 × 5 inches\u003c\/strong\u003e for these model packages; confirm actual carton before carrier rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBE-961-1 vs BE-961-2 — Which Should You Choose?\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eBE-961-1 Standard\u003c\/th\u003e\n\u003cth\u003eBE-961-2 Supervised\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e120VAC to 9VDC device power\u003c\/td\u003e\n\u003ctd\u003eYes, external transformer included\u003c\/td\u003e\n\u003ctd\u003eYes, external transformer included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10-foot armored conduit \/ LED\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in supervisory loop and 95 dB alarm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECL-230 \/ ECL-600 exit-control locks\u003c\/td\u003e\n\u003ctd\u003eCompatible approved versions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDesigned specifically for these locks\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV40 \/ V50 EB exit alarms\u003c\/td\u003e\n\u003ctd\u003eCompatible approved versions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo — ECL-only configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAX-300 \/ EAX-500 alarms\u003c\/td\u003e\n\u003ctd\u003eCompatible approved versions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo — ECL-only configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup battery or charger supplied\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\n\u003cp\u003eEach selected model includes a genuine \u003cstrong\u003eDetex BE-961-series battery eliminator\u003c\/strong\u003e in standard cast-aluminum wall-mount housing, an \u003cstrong\u003eexternal 120VAC-to-12VAC transformer\u003c\/strong\u003e, \u003cstrong\u003e10-foot armored flex connecting conduit\u003c\/strong\u003e, LED indicator, and manufacturer-standard power-conversion electronics. \u003cstrong\u003eBE-961-2 additionally incorporates a secure supervisory power loop and internal 95 dB alarm\u003c\/strong\u003e. Confirm current factory-supplied wiring and hardware with the distributor's packing list.\u003c\/p\u003e\n\u003ch3\u003eSold Separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetex ECL exit-control locks, V40\/V50 battery alarm exit devices, EAX alarm housings, or other connected equipment\u003c\/li\u003e\n\u003cli\u003eOutdoor NEMA battery-eliminator enclosure, additional protective conduit and specialized door power-transfer parts\u003c\/li\u003e\n\u003cli\u003eBattery-backup equipment, rechargeable batteries and accessories for emergency standby power\u003c\/li\u003e\n\u003cli\u003eDoor, frame, locking hardware and installation labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBE-961-1: 3 lb\u003c\/strong\u003e shipping weight. \u003cstrong\u003eBE-961-2: 3 lb\u003c\/strong\u003e shipping weight. Distributor-listed shipping cartons for this product family are approximately \u003cstrong\u003e10 × 7 × 5 inches\u003c\/strong\u003e. These packed weights are \u003cstrong\u003eseparate from the case dimensions of 4-5\/8 × 4-5\/8 × 2 inches\u003c\/strong\u003e. The BE-961-1 original Shopify weight and stock have been preserved. Verify actual warehouse packaging or carrier weight before purchasing a shipping label.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Life-Safety Information\u003c\/h3\u003e\n\u003cp\u003eHave a qualified installer follow the current \u003cstrong\u003eDetex installation instructions 101320\u003c\/strong\u003e and the exact connected-device installation manual. Verify the utility supply, transformer hookup, output jumper settings, connector and cable routing, maximum combined current, ground\/short protection, and compatibility of the installed lock with the selected BE-961 model. \u003cstrong\u003eThe 95 dB supervised alarm is available only on the BE-961-2 ECL-specific configuration\u003c\/strong\u003e. Do not use that version with V40, V50 or EAX devices unless Detex provides explicit approval for the exact hardware; manufacturer catalog restrictions take precedence over third-party retailer summaries. The battery eliminator is \u003cstrong\u003enot\u003c\/strong\u003e an emergency power backup, exit device, delayed-egress timer or fire-alarm release system.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"BE-961-1 - Standard (No Supervisory Alarm)","offer_id":68054827008215,"sku":"DTX-BE-961-1","price":250.71,"currency_code":"USD","in_stock":true},{"title":"BE-961-2 - Supervised (95 dB Alarm, ECL Only)","offer_id":68054957424855,"sku":"DTX-BE-961-2","price":438.05,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/DET100BE9611.png?v=1794516935","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-be-961-1-battery-eliminator-120vac-to-9vdc-with-10-ft-conduit","provider":"Commercial Door Worx","version":"1.0","type":"link"}