- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex EAX-2500F / FK Gray Flush-Mount Exit Alarm | Configurations & Kits
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex EAX-2500F / FK Gray Flush-Mount Exit Alarm | Configurations & Kits
Detex EAX-2500F / FK Gray Flush-Mount Exit Alarm | Configurations & Kits
$642.00
$395.47
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detex EAX-2500F / EAX-2500FK Gray — 100 dB Flush-Mount Exit Door Alarm and Complete Installation Kit Options. The Detex EAX-2500 Series is a professional AC/DC externally powered wall-mounted exit alarm for monitoring doors that should not be used without authorization. Its compact flush-mount gray alarm is designed for a standard 4 in × 4 in electrical box and emits an approximately 100 dB piezo alarm when the attached magnetic door contact signals that an armed door has opened. The product family offers standard alarm-only units, multiple factory-installed key-control configurations, and FK complete flush-mount kits that include a flush magnetic switch and 24VAC transformer.
Important: This is audible security monitoring only. The alarm does not prevent, lock, delay or impede emergency egress, and is not an EE delayed-egress device. Compatible exit hardware, door latching, door closer, power wiring and any fire-door requirements remain separate. Select the exact SKU below to receive the specified cylinder or kit components.
Additional Product Specifications and Ordering Guidance
EAX-2500 Mounting, Keying and Alarm Options
The Detex EAX-2500 Series provides exit alarming in factory surface-mount or flush-mount configurations. Related F, FK, S and SK model codes can identify different housings, key-stop or keying options. The alarm is an exit-monitoring device, not an electric lock or delayed-egress controller.
Model and Option Identification
| Available Configuration | SKU |
|---|---|
| Alarm Configuration: Standard — No Cylinder | DTX-EAX-2500F-GRAY |
| Alarm Configuration: IC7 — 7-Pin Housing (Core Not Included) | DTX-EAX-2500F-GRAY-IC7 |
| Alarm Configuration: W-CYL KA — Mortise Cylinder (Keyed Alike) | DTX-EAX-2500F-GRAY-W-CYL-KA |
| Alarm Configuration: KS — Key Stop (No Cylinder) | DTX-EAX-2500F-KS-GRAY |
| Alarm Configuration: MC65 — Factory Mortise Cylinder | DTX-EAX-2500F-MC65-GRAY |
| Alarm Configuration: FK — Flush Kit (No Cylinder) | DTX-EAX-2500FK-GRAY |
| Alarm Configuration: FK IC7 — Flush Kit + IC7 Housing (Core Extra) | DTX-EAX-2500FK-GRAY-IC7 |
| Alarm Configuration: FK W-CYL KA — Kit + Keyed-Alike Cylinder | DTX-EAX-2500FK-GRAY-W-CYL-KA |
Product Selection and Installation Checklist
- Choose flush-mount versus surface-mount construction based on the existing or approved door preparation.
- Confirm black/gray finish, keyed arming/reset, cylinder housing or key-stop option and whether the specific factory kit includes a cylinder.
- Review the specified alarm power input, triggering switch, cable and any external monitor or remote-horn interface.
- Check compatibility with the host exit device, wall/door clearance, frame, and any weatherization requirements; standard devices are not assumed outdoor rated.
Acceptance and Service Verification
Test alarm arming, unauthorized door operation, local audible warning, authorized disarming/reset and any remote indications.
Factory Package and Related Components
One selected alarm unit or conversion kit; site wiring, external switch, access reader and separately specified cylinders are not automatically included. Consult the original model specifications below when matching the factory SKU to an existing opening.
Choose the Correct Configuration — 8 Factory Options
The options all use the Detex EAX-2500 flush-mount gray 100 dB exit alarm. The main differences are whether a mortise cylinder or IC housing comes factory-installed, whether the KS key-stop mechanism is specified, and whether the package includes the flush contact and transformer.
| Configuration | SKU | Exactly What Changes |
|---|---|---|
| Standard — No Cylinder | DTX-EAX-2500F-GRAY | Base gray flush alarm. Standard flush back box and EA-561 sign included; mortise cylinder, magnetic door contact and transformer sold separately. |
| IC7 — Housing, No Core | DTX-EAX-2500F-GRAY-IC7 | Base flush alarm with factory-installed seven-pin interchangeable-core (IC7) housing; removable core and keys NOT included. Door contact and transformer sold separately. |
| W-CYL KA — Keyed Alike | DTX-EAX-2500F-GRAY-W-CYL-KA | Base flush alarm with a factory-supplied conventional mortise cylinder keyed alike. Confirm required facility keying; contact and transformer sold separately. |
| KS — Key Stop | DTX-EAX-2500F-KS-GRAY | Base flush alarm with factory-installed Key Stop (KS), requiring the key switch in the armed/on position for key removal. No mortise cylinder included; contact and transformer sold separately. |
| MC65 — Mortise Cylinder | DTX-EAX-2500F-MC65-GRAY | Base flush alarm with factory-installed Detex MC65 conventional mortise cylinder, 1-1/8 in, Schlage C keyway, brushed-chrome finish. MC65 does not automatically mean keyed alike. Contact and transformer sold separately. |
| FK — Complete Flush Kit, No Cylinder | DTX-EAX-2500FK-GRAY | EAX-2500FK Gray complete installation kit with 24VAC transformer, flush magnetic switch contact, flush back box and EA-561 warning sign. Mortise control cylinder sold separately. |
| FK IC7 — Complete Kit + IC7 Housing | DTX-EAX-2500FK-GRAY-IC7 | Everything in FK complete flush kit PLUS factory-installed seven-pin IC7 interchangeable-core housing. Removable IC core, control key and operating keys NOT included. |
| FK W-CYL KA — Complete Kit + Keyed-Alike Mortise Cylinder | DTX-EAX-2500FK-GRAY-W-CYL-KA | Complete gray flush-mount exit-alarm kit with 24VAC transformer, flush magnetic switch contact, back box, EA-561 warning sign and a factory-supplied conventional mortise cylinder keyed alike (KA). Confirm specific facility keying and compatibility with the supplier. |
FK versus F: The F alarm alone requires a separately purchased suitable magnetic door contact and power transformer. The FK model bundles a flush magnetic contact and a 24VAC transformer with the gray EAX-2500F alarm. The IC7 option adds a factory-installed housing but does not supply a removable cylinder core or keys. FK IC7 is not a substitute for FK with a complete keyed mortise cylinder. It is also not the C / FC retrofit conversion plate for an older EA-2500F.
FK Complete Installation Kit — What Is Included
Select FK — Flush Kit (No Cylinder), FK IC7 — Flush Kit + IC7 Housing, or FK W-CYL KA — Flush Kit + Keyed-Alike Cylinder when a new hardwired installation needs the primary electrical and door-monitoring accessories bundled with the alarm. The factory FK package includes:
- Detex EAX-2500F Gray flush-mounted exit-alarm electronics and faceplate with approximately 100 dB piezo horn and key-operated alarm controls.
- 24VAC transformer for the approved alarm power arrangement, subject to correct field electrical installation.
- Flush magnetic door switch contact to detect opening of the monitored door when the system is armed.
- Manufacturer flush back box for the Detex-specified 4 in × 4 in rough-in.
- EA-561 emergency-exit alarm warning sign, standard English alarm signage.
- Standard manufacturer installation and mounting components according to the factory kit packing list.
- FK IC7 only: Factory-installed 7-pin interchangeable-core cylinder housing for the key-control function, less removable core and keys.
- FK W-CYL KA only: Factory-supplied keyed-alike conventional mortise cylinder; verify the facility's keying requirements with the supplier.
The standard FK kit does not include an operating mortise cylinder. The FK IC7 includes only the interchangeable-core housing, not the actual keyed core. The FK W-CYL KA adds a factory-supplied keyed-alike conventional mortise cylinder to the otherwise complete FK kit. Specify the correct 7-pin interchangeable-core profile, keyway, control key, and operating keys separately. A detachable 7-pin core should not be assumed interchangeable with a complete MC65 conventional mortise cylinder.
EAX-2500F Gray Standard Alarm — What's Included
The Standard, IC7, W-CYL KA, KS and MC65 models include the gray flush-mounted alarm, Detex-standard EA-561 warning sign and manufacturer back box, with the selected key-control option as indicated. These five non-FK versions do not bundle the magnetic door contact or transformer. They require separately supplied Detex-approved door contacts, hardwired power and field installation. Do not assume the pictured cylinder is supplied unless the chosen variant explicitly includes one.
Features and Benefits
- Detex EAX-2500 Series: Heavy-duty AC/DC external-powered wall-mounted exit alarm for commercial and institutional doors.
- Loud approximately 100 dB piezo output: Immediate audible warning when an armed monitored door is opened without authorization.
- Standard gray finish: Professional neutral gray housing that coordinates with commercial architectural door hardware.
- Flush-mount installation: Compact faceplate fits a standard 4 in × 4 in double-gang electrical back box.
- Hardwired alarm power: Suitable Detex-approved 12/24V AC/DC power arrangement; FK kits specifically include a compatible 24VAC transformer.
- Door magnetic contact activation: Door-opening signals start the audible alarm while armed; flush contact is included only on FK kits.
- Remote alarm signaling: Compatible remote relay output for monitoring or annunciation equipment.
- Remote bypass: Enables authorized bypass for security staff, building systems or approved controlled passage.
- Extended bypass function: When properly configured, accommodates controlled open-door periods and rearming after closure.
- Manual key reset / arming: An appropriate cylinder and key permit authorized arming, disarming and reset.
- KS key-stop option: Factory switch option retains the key unless the alarm is in the armed/on position; sold as its own variant.
- MC65 cylinder option: Factory-installed conventional mortise cylinder, different from IC7 interchangeable-core housing and from the W-CYL KA keying arrangement.
- IC7 housing option: Factory-installed seven-pin IC housing, removable core and keys sold separately, available in both alarm-only and FK kit models.
- Automatic rearming capability: Field-selectable two-minute automatic rearm, with additional extended-bypass/rearm settings depending on device programming.
- Silent arming and status options: Field-selectable status/arming settings according to Detex instructions.
- Low-backup-battery monitoring: Alarm status provisions support optional 9V battery backup; check the exact factory configuration because L9 removes backup.
- EA-561 warning sign: Included with the standard alarm and complete FK kits.
- Not delayed egress: Horn and monitoring features do not intentionally hold the door locked or delay emergency release.
- Suitable for high-use facilities: Commonly used in commercial buildings, schools, healthcare buildings, warehouses, institutions and security-sensitive exits.
Detailed Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Product Family | EAX-2500F / EAX-2500FK AC/DC external-powered, flush-mount exit alarm |
| Color / Finish | Standard GRAY |
| Mounting Style | F = flush mount to suitable 4 in × 4 in back box |
| Audible Alarm | Approximately 100 dB piezo horn |
| Primary Power | Detex-approved hardwired AC/DC supply; FK kit furnishes 24VAC transformer |
| Door Monitoring | Magnetic door switch contact, included on FK variants; required separately on non-FK variants |
| Remote Alarm Relay | Supported for compatible facility security system interface |
| Remote Bypass | Supported; extended-bypass settings subject to Detex programming |
| Alarm Rearming | Manual keyed reset or selectable 2-minute automatic rearm per approved setting |
| Factory Alarm Arming Delay | Typically 15 seconds; alternative factory settings available. This is NOT a delay on physical egress. |
| Key Control / Cylinder | Varies by selected variant: standard no cylinder; IC7 housing less core; W-CYL KA keyed-alike mortise cylinder; KS Key Stop less cylinder; MC65 preinstalled mortise cylinder; FK W-CYL KA complete kit with keyed-alike mortise cylinder |
| IC7 | Factory-installed 7-pin interchangeable-core housing, core and keys not included |
| FK IC7 | Complete FK flush kit with 24VAC transformer, flush magnetic contact, back box, EA-561 sign and factory 7-pin IC housing, less removable core |
| MC65 | Factory-installed 1-1/8-in conventional mortise cylinder, Schlage C keyway; not automatically keyed alike to facility locks |
| W-CYL KA | Conventional factory mortise cylinder ordered keyed alike; confirm requested common keying separately |
| KS Key Stop | Factory key-stop switch, allows key removal only while armed/on; operating cylinder separately required |
| Conversion Plate (C / FC) | NOT included with F, FK or FK IC7; Detex 102640 EA-2500F retrofit conversion is a separate model/option |
| Alarm Face | Approx. 4.65 in wide × 4.60 in high; verify exact installation drawing |
| Projection | Approx. 1.0 in beyond flush box; verify current drawing |
| Backup Power | 9V backup provision, subject to exact order; L9 option removes backup |
| Contact Mounting | Flush door magnetic switch for FK kit; install to suit door/frame gap and manufacturer template |
| Transformer Included? | Yes on FK, FK IC7 and FK W-CYL KA; no on five alarm-only F configurations |
| Mortise Cylinder / Removable Core Included? | Base FK: no cylinder. FK IC7: housing yes, core and keys no. FK W-CYL KA: factory-supplied keyed-alike mortise cylinder included. Other variants as described above. |
| Shipping Weight (estimated) | Standard F 2.1 lb; IC7 F 2.5 lb; W-CYL KA F 2.5 lb; KS F 2.2 lb; MC65 F 2.5 lb; FK Gray 5 lb; FK Gray IC7 5 lb; FK Gray W-CYL KA 5 lb. Verify actual packed weight before carrier fulfillment. |
| Required Local Compliance | Free mechanical egress and compatible fire-door/door-closing function must be maintained; install per manufacturer instructions and local codes. |
Recommended Applications
- Commercial emergency exits: Audible alert for unauthorized door openings without restricting emergency exit.
- Schools, universities, hospitals and government facilities: Monitor egress doors where staff need a local warning.
- Warehouses and distribution centers: Loss prevention, shipping-area exit monitoring and restricted personnel-door alarms.
- Retail and public facilities: Alert security personnel when a door is opened outside authorized procedures.
- New full flush-mount installations: Choose FK when you need the compatible transformer and magnetic contact in the same order.
- Facilities standardizing keyed-alike cylinders: Choose FK W-CYL KA when a full alarm kit and keyed-alike mortise cylinder are both needed; confirm exact keying with the supplier.
- Facilities using a 7-pin interchangeable-core key system: Choose FK IC7 if the electrical kit and a factory-installed 7-pin IC housing are required; add a compatible removable core and keys.
What Is Not Included — Important Selection Notes
All variants: Door, commercial exit bar/lockset, electrical field wiring, central monitoring panel, extra security controls, installation labor and the separate Detex 102640 retrofit conversion plate are excluded unless expressly quoted. F without K: Flush magnetic contact and transformer are extra. FK (without IC7): A suitable operating mortise cylinder and keys must be ordered separately. FK IC7: The seven-pin IC housing is factory-installed, but its interchangeable core and keys are not included. FK W-CYL KA: Factory-supplied keyed-alike conventional mortise cylinder included, with exact keying to be confirmed. The magnetic contact and transformer ARE included in all three FK kit configurations. Confirm the exact 9V backup-battery option and the vendor packing list before installation.
Ordering and Installation Guidance
Model decoding: EAX-2500 = external-powered exit alarm; F = flush mount; FK = full flush-mount installation kit with flush magnetic door contact and 24VAC transformer; GRAY = standard gray; IC7 = factory 7-pin interchangeable-core housing (core not included); MC65 = complete factory mortise cylinder; W-CYL KA = keyed-alike conventional cylinder; KS = Key Stop. Coordinate compatible transformer wiring, door-contact placement, mortise cylinder or interchangeable core, facility keying, and any remote relay/bypass input. Do not assume IC7 includes the physical keying core. Confirm Detex installation instructions, alarm test and free egress requirements with the site installer. Shipping weights are preliminary estimates only and should be replaced with actual sealed-carton values before fulfilling UPS orders.