- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex ECL-230D Alarmed Exit Control Lock | Black
Replacement part details
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex ECL-230D Alarmed Exit Control Lock | Black
Detex ECL-230D Alarmed Exit Control Lock | Black
$594.00
$365.90
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detex ECL-230D Black — Battery-Powered Alarmed Exit Control Lock, 100 dB, 1-Inch Deadbolt
Secure secondary commercial exits while maintaining immediate emergency egress with the Detex ECL-230D. This heavy-duty, black-finish, short-paddle exit control lock combines a saw-resistant single-point 1-inch throw deadbolt, a loud 100 dB battery-operated alarm, and a highly visible photoluminescent English push-plate sign. Ideal for loss prevention in retail, stockrooms, warehouses, distribution centers and commercial or institutional buildings.
Additional Product Specifications and Ordering Guidance
Exit-Control Lock, Alarm and Keying Selection
Detex ECL exit-control locks combine a mechanical locking function with specified alarm or security-control features. The correct ECL-230D, ECL-230X, weatherized or ECL-600 configuration must be selected for the original opening and manufacturer-approved latch/strike mounting arrangement.
Factory item on this listing: DTX-ECL-230D-BLACK.
Product Selection and Installation Checklist
- Identify the exact ECL series and confirm whether the assembly uses a deadbolt, long-bar, multiple locking points or a specified fire-rated configuration.
- Check mounted door width, stile/face clearance, strike locations, compatible door/frame and the factory black/gray finish.
- Determine the required cylinder, keys, battery or power source, key override, alarm arming and reset methods.
- For weatherized, delayed-egress or fire-exit applications, verify the manufacturer-approved model and full assembly listing rather than relying on common cover dimensions.
Acceptance and Service Verification
Confirm authorized access, alarm activation, lock engagement, interior release, key override/reset and the approved emergency-egress behavior.
Factory Package and Related Components
One ECL lock assembly as specified by its SKU. Extra trim, keys, strike accessories, controllers and installation are separate unless listed in the factory kit. Consult the original model specifications below when matching the factory SKU to an existing opening.
This listing is for the ECL-230D BLACK standard short-bar model. A compatible 5- to 7-pin rim cylinder is required but sold separately. The separate ECL-230D-PH is the long-bar configuration; the ECL-600 is the applicable Detex fire-exit-hardware series for appropriately rated doors.
Key Features and Benefits
- 100 dB audible alarm: Alerts occupants and facility staff when a controlled secondary exit is operated without authorization.
- 1-inch throw, saw-resistant deadbolt: Rugged single-point exit locking for demanding commercial openings.
- Heavy-duty security: Manufacturer describes attack resistance of over 2,200 lb of outside pull force.
- 9-volt battery operation: Battery included; no external electrical transformer or line-voltage wiring required for the onboard alarm.
- Alarm and lock coordination: Locking and unlocking the deadbolt automatically arms and disarms the alarm.
- Key-controlled alarm reset: Reset requires an appropriate control key.
- Photoluminescent push plate: Absorbs ambient light to help maintain visibility when surrounding light levels drop.
- Non-handed: Designed for compatible left-hand or right-hand doors.
- Rim-cylinder flexibility: Accommodates compatible 5-, 6- or 7-pin standard and interchangeable-core rim cylinders. Cylinder not included.
- Commercial panic hardware: ECL-230D series is UL-listed panic hardware; confirm suitability with the complete opening and applicable local codes.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Series / Model | ECL-230D standard short-paddle exit control lock |
| Manufacturer Configuration | ECL-230D BLACK |
| Finish | Black |
| Device Type | Battery-alarmed single-point exit control deadbolt |
| Alarm Sound | Approximately 100 dB |
| Power | One 9V battery, included |
| Deadbolt | Single point, saw resistant, 1-inch throw |
| Exterior Pull Resistance | Over 2,200 lb (manufacturer design rating) |
| Door Handing | Non-handed |
| Door Thickness | Commonly used on 1-3/4-inch through 2-1/4-inch doors; verify preparation |
| Door Material | Compatible wood, hollow metal or aluminum doors with suitable reinforcement and preparation |
| Cylinder Requirement | 5- to 7-pin standard or interchangeable-core rim cylinder, sold separately |
| Control / Reset | Deadbolt operation arms/disarms; control key required for alarm reset |
| Push Plate | Short metal photoluminescent English warning paddle/sign |
| Standard Strike | ECL-437K adjustable surface strike; confirm factory kit contents and site preparation |
| Fire-Rated Openings | Standard ECL-230D is not the fire-rated ECL-600 model; confirm rating before installation |
Applications
- Retail rear doors, stockroom and inventory-control exits
- Warehouses, distribution centers and shipping/receiving areas
- Schools, healthcare facilities and government support areas
- Commercial buildings requiring audible monitoring of secondary exits
- Facility loss prevention without preventing immediate egress
Included and Not Included
Included: Black ECL-230D short-paddle exit control device with 100 dB alarm, photoluminescent warning sign and 9V battery. Typical standard factory hardware includes cover lock/keys and compatible keeper hardware; verify the supplied package against the current Detex kit specification.
Not included: Operating rim cylinder, facility keying or master-key system, installation labor and nonstandard accessories. Do not confuse the cover-lock keys with the separate operating rim cylinder.
Ordering and Installation Notes
Verify the required exit-hardware listing, door width, thickness, stile, frame/strike preparation and cylinder configuration before purchase. For long-paddle applications, select ECL-230D-PH; for fire-rated applications, consult Detex ECL-600; and for exposed exterior environments, check approved weatherized Detex alternatives. Follow applicable fire, building and life-safety codes and the latest manufacturer installation instructions.