- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex ECL-230X Alarmed Exit Locks | 1–5 Point
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex ECL-230X Alarmed Exit Locks | 1–5 Point
Detex ECL-230X Alarmed Exit Locks | 1–5 Point
$1,242.00
$765.07
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detex ECL-230X Alarmed Exit Control Locks | Single- to Five-Point Security
The Detex ECL-230X series combines mechanically secured panic-exit operation with an integrated 100 dB battery-powered alarm and a high-visibility photoluminescent English push-plate sign. Choose from single-point, two-point, three-point or five-point locking to match the approved secondary-exit opening. These nine selections are standard Gray, non-weatherized configurations with different locking arrangements, door-height options and operating-cylinder packages.
These are panic-exit control locks, not automatically fire-rated fire-exit devices. Confirm the opening's required hardware listing, door dimensions, access control and local life-safety requirements before selecting a configuration. Standard Detex ECL-230X hardware is designed for 36–48 in. door widths; extended-height options are available for selected multi-point models.
Compare the Nine Available Configurations
| Selection | Locking Points / Door Application | Operating Cylinder |
|---|---|---|
| ECL-230X — Standard Gray | 1 point: 1 in. throw central deadbolt | Not included. Order compatible rim cylinder and keys separately. |
| ECL-230X W-CYL KA | 1 point: same central deadbolt | Included: conventional operating rim cylinder, keyed alike. Verify keyway and matching-key group. |
| ECL-230X-TB | 2 points: top and bottom locking bolts; no central deadbolt | Not included. Factory-standard cover lock does not replace the operating rim cylinder. |
| ECL-230X-TD | 2 points: top bolt plus central deadbolt | Not included. Order compatible rim cylinder and keys separately. |
| ECL-230X-TDB | 3 points: top bolt, central deadbolt and bottom bolt | Not included. Order compatible rim cylinder and keys separately. |
| ECL-230X-TDB 96 | 3 points: TDB arrangement with extended-height rods for 7–8 ft doors | Not included. Order compatible rim cylinder and keys separately. |
| ECL-230X-TDB DX2 IC7R | 5 points: TDB's three bolts plus two DX2 hinge-side bolts | IC7R small-format interchangeable-core rim housing installed. Removable 7-pin core, operating keys and core control key are extra. |
| ECL-230X-TDB IC7R | 3 points: TDB arrangement without DX2 hinge-side bolts | IC7R small-format interchangeable-core rim housing installed. Removable 7-pin core and keys are extra. |
| ECL-230X-TDB W-CYL KA | 3 points: top bolt, central deadbolt and bottom bolt | Included: conventional operating rim cylinder, keyed alike. Confirm facility keying requirements. |
Important: TB means top and bottom bolts with no central deadbolt. TD means top bolt plus deadbolt. TDB means top, deadbolt and bottom. TDB 96 refers to the extended-height rod configuration, not additional locking points. DX2 adds two hinge-side locking bolts, creating five points on the TDB configuration. IC7R supplies a rim-cylinder housing but not the removable interchangeable core or its keys.
Key Features
- 100 dB audible exit alarm: Battery-operated local warning helps alert personnel when the protected secondary exit is activated.
- Photoluminescent push-plate sign: English emergency-exit warning sign absorbs ambient light for better visibility in low-light conditions.
- 9V battery operation: Standard alarm power uses a supplied 9-volt battery. A compatible BE-961 power-conversion accessory is available separately where specified.
- One- to five-point mechanical security: A central 1 in. throw, saw-resistant deadbolt is used on configurations that include a deadbolt; selected multi-point models add 3/4 in. throw top and/or bottom locking bolts.
- Alarm control and reset: Follow the factory instructions for arming/disarming on the selected configuration. Alarm reset uses the designated control key.
- Low-profile, non-handed design: Standard ECL-230X profile is designed to meet the manufacturer's 4 in. maximum-projection guidance and for suitable left- or right-hand openings.
- Multiple cylinder packages: Choose a less-cylinder model, a factory W-CYL KA keyed-alike conventional rim cylinder, or an IC7R small-format interchangeable-core housing supplied less core and keys.
- Extended-height and hinge-side options: TDB 96 accommodates a specified 7–8 ft door height; the TDB DX2 IC7R uses two additional hinge-side bolts and mounting components.
- Service-door applications: Suitable for appropriately specified warehouse, retail, stockroom, industrial and institutional secondary exits.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Series | ECL-230X alarmed exit control hardware |
| Finish | Gray, standard non-weatherized |
| Locking Configurations | Single point; TB or TD two-point; TDB three-point; TDB DX2 five-point |
| Deadbolt | 1 in. throw, saw-resistant, on models that include a central deadbolt |
| Top / Bottom Locking Bolts | 3/4 in. throw on applicable TB, TD and TDB arrangements |
| Alarm Sound | Approx. 100 dB |
| Alarm Power | 9V battery, supplied |
| Signage | Photoluminescent English exit-warning push plate |
| Standard Door Width | 36–48 in.; confirm actual application and factory template |
| TDB Rod-Height Options | Standard 84 in. arrangement for 6 ft 8 in.–7 ft doors; TDB 96 for 7–8 ft doors |
| Handing | Non-handed, subject to door preparation |
| Operating Cylinder | Compatible rim cylinder; W-CYL KA variants include a keyed-alike conventional cylinder |
| IC7R Option | Factory-installed small-format interchangeable-core rim-cylinder housing; removable core and keys not supplied |
| Environmental Configuration | Non-weatherized; Detex ECL-230X-W weatherized models are separate |
| Fire-Exit Rating | Do not assume fire-rated fire-exit hardware; verify the listed assembly required by the opening |
What Is Included
One Detex ECL-230X series alarmed exit-control lock in the selected configuration, with the manufacturer's standard push plate, alarm components, 9V battery, and model-specific mechanical locking assemblies and factory mounting/strike components. W-CYL KA models include the specified keyed-alike operating rim cylinder. IC7R models include the installed interchangeable-core rim housing but do not include a removable core or keys. The DX2 variant includes the two designated hinge-side locking bolts and associated mounting components. Confirm exact package contents against the Detex packing list for the ordered model.
Sold Separately
Operating rim cylinder and keys on standard less-cylinder models; removable 7-pin small-format interchangeable core, keys and applicable core-control key for IC7R models; optional exterior trim, power conversion, specialty strikes/rod guards and other accessories not expressly part of the selected factory model; door, frame and installation services.
Ordering and Life-Safety Notes
Before ordering, verify the number and location of locking points, actual door width and height, the correct rod and strike arrangement, factory-approved mounting template, rim cylinder or IC core format, keyway/keying, Gray finish and non-weatherized exposure conditions. The ECL-230X-W weatherized family and ECL-600 fire-exit hardware are separate products with different application requirements.
Follow current Detex ECL-230X installation instructions for the specific variant. Test mechanical engagement of every locking point, alarm operation, control-key reset and unrestricted interior emergency egress. Comply with the approved panic/exit hardware listing and the authority having jurisdiction; this listing does not by itself establish fire-door compatibility.