{"product_id":"detex-ecl-600-fire-rated-alarmed-exit-control-lock-black","title":"Detex ECL-600 Fire-Rated Alarmed Exit Control Lock | Black or Gray","description":"\u003cp\u003e\u003cstrong\u003eDetex ECL-600 Fire-Rated Alarmed Exit Control Lock | Black or Gray | Long Bar | 100 dB Exit Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProtect commercial fire-exit openings while maintaining positive relatching with the \u003cstrong\u003eDetex ECL-600\u003c\/strong\u003e, a rugged \u003cstrong\u003eWarnock Hersey-listed fire-exit control lock\u003c\/strong\u003e featuring a long push bar, a \u003cstrong\u003e100-decibel audible alarm\u003c\/strong\u003e, a \u003cstrong\u003e1-inch saw-resistant deadbolt\u003c\/strong\u003e, and a \u003cstrong\u003e3\/4-inch deadlocking latchbolt\u003c\/strong\u003e. Choose the \u003cstrong\u003eBlack or Gray factory finish\u003c\/strong\u003e to coordinate with compatible 36- to 48-inch-wide exit doors in retail, industrial, commercial, institutional and warehouse facilities.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eAdditional Product Specifications and Ordering Guidance\u003c\/h3\u003e\n\u003ch4\u003eExit-Control Lock, Alarm and Keying Selection\u003c\/h4\u003e\n\u003cp\u003eDetex ECL exit-control locks combine a mechanical locking function with specified alarm or security-control features. The correct ECL-230D, ECL-230X, weatherized or ECL-600 configuration must be selected for the original opening and manufacturer-approved latch\/strike mounting arrangement.\u003c\/p\u003e\n\u003ch4\u003eModel and Option Identification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAvailable Configuration\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Black\u003c\/td\u003e\n\u003ctd\u003eDTX-ECL-600-BLACK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish: Gray\u003c\/td\u003e\n\u003ctd\u003eDTX-ECL-600-GRAY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProduct Selection and Installation Checklist\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify the exact ECL series and confirm whether the assembly uses a deadbolt, long-bar, multiple locking points or a specified fire-rated configuration.\u003c\/li\u003e\n\u003cli\u003eCheck mounted door width, stile\/face clearance, strike locations, compatible door\/frame and the factory black\/gray finish.\u003c\/li\u003e\n\u003cli\u003eDetermine the required cylinder, keys, battery or power source, key override, alarm arming and reset methods.\u003c\/li\u003e\n\u003cli\u003eFor weatherized, delayed-egress or fire-exit applications, verify the manufacturer-approved model and full assembly listing rather than relying on common cover dimensions.\u003c\/li\u003e\n\u003cli\u003eFor labeled fire exits, retain the complete listed assembly, certified mounting and latching configuration, fire-door-compatible strike and required no-dogging behavior.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAcceptance and Service Verification\u003c\/h4\u003e\n\u003cp\u003eConfirm authorized access, alarm activation, lock engagement, interior release, key override\/reset and the approved emergency-egress behavior.\u003c\/p\u003e\n\u003ch4\u003eFactory Package and Related Components\u003c\/h4\u003e\n\u003cp\u003eOne ECL lock assembly as specified by its SKU. Extra trim, keys, strike accessories, controllers and installation are separate unless listed in the factory kit. Consult the original model specifications below when matching the factory SKU to an existing opening.\u003c\/p\u003e\u003c\/section\u003e\n\u003cp\u003e\u003cstrong\u003eChoose Black or Gray. Both finishes ship without the operating rim cylinder.\u003c\/strong\u003e It includes the factory cover lock with two keys, a 9V alarm battery, standard keeper and strike kit, and Detex's ECL-2109 English photoluminescent paddle-bar sign, subject to the current manufacturer packing list. \u003cstrong\u003eCover-lock keys are not a substitute for the separately required operating rim cylinder and its keys.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eChoose Your Finish\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFinish Variant\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECL-600 BLACK\u003c\/td\u003e\n\u003ctd\u003eBlack-finish fire-rated relatching exit control lock, 100 dB battery alarm, 1-inch deadbolt, 3\/4-inch deadlocking latchbolt, long operating bar. \u003cstrong\u003eOperating rim cylinder sold separately.\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGray\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECL-600 GRAY\u003c\/td\u003e\n\u003ctd\u003eGray-finish version of the same ECL-600 fire-rated relatching exit control lock, with identical alarm, deadbolt\/latchbolt, bar and fire-hardware configuration. \u003cstrong\u003eOperating rim cylinder sold separately.\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBoth finishes include the factory-supplied cover lock and its keys, 9V alarm battery, keeper\/strike kit, and photoluminescent English exit plate. Confirm the actual door, frame and strike requirements for the rated assembly.\u003c\/p\u003e\n\u003ch3\u003eFire-Rated Exit Hardware with Automatic Relatching\u003c\/h3\u003e\n\u003cp\u003eUnlike a conventional single-deadbolt alarmed exit control device, the \u003cstrong\u003eDetex ECL-600\u003c\/strong\u003e uses a \u003cstrong\u003e1-inch throw saw-resistant deadbolt\u003c\/strong\u003e together with a \u003cstrong\u003e3\/4-inch deadlocking latchbolt\u003c\/strong\u003e. The latchbolt provides an automatic relatching function when the door closes, helping maintain the positive-latching performance required on compatible fire-rated exit openings.\u003c\/p\u003e\n\u003cp\u003eThe ECL-600 is identified by Detex as \u003cstrong\u003eWarnock Hersey-listed fire exit hardware\u003c\/strong\u003e with a \u003cstrong\u003emaximum three-hour listing\u003c\/strong\u003e for properly configured fire door assemblies: \u003cstrong\u003esingle doors up to 4 ft x 8 ft\u003c\/strong\u003e, or \u003cstrong\u003epairs up to 8 ft x 8 ft\u003c\/strong\u003e with the required approved hardware and compatible fire-rated mullion where specified. The door, frame, strikes, closer, assembly and installation must each meet applicable listings, codes and approvals. The device alone does not make an opening fire-rated.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-exit hardware:\u003c\/strong\u003e Warnock Hersey-listed ECL-600 long-bar exit control for suitable listed three-hour openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo mechanical latching elements:\u003c\/strong\u003e The \u003cstrong\u003e1-inch deadbolt\u003c\/strong\u003e provides added security, while the \u003cstrong\u003e3\/4-inch deadlocking latchbolt\u003c\/strong\u003e relatches as the door closes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated 100 dB audible alarm:\u003c\/strong\u003e Alerts facility personnel to exit activation and helps discourage unauthorized use of a protected secondary exit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V battery operated:\u003c\/strong\u003e A 9-volt battery is supplied; an optional \u003cstrong\u003eBE-961 hardwired conversion kit\u003c\/strong\u003e is available separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArms and disarms with the deadbolt:\u003c\/strong\u003e Locking\/unlocking the deadbolt operates the alarm arming function as designed by Detex.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey-controlled alarm reset:\u003c\/strong\u003e Alarm reset requires the designated cover-lock control key.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttack-resistant construction:\u003c\/strong\u003e Saw-resistant deadbolt and corrosion-resistant alloy lock body; Detex reports resistance exceeding \u003cstrong\u003e2,200 lb of outside pull force\u003c\/strong\u003e under its stated test conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotoluminescent exit signage:\u003c\/strong\u003e Durable steel \u003cstrong\u003eECL-2109 English push plate\u003c\/strong\u003e provides visible emergency-exit instructions, even after lighting is reduced.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong operating bar:\u003c\/strong\u003e Designed for \u003cstrong\u003e36- to 48-inch-wide doors\u003c\/strong\u003e, including common 3 ft and 4 ft commercial openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-handed:\u003c\/strong\u003e Compatible with appropriate left- and right-hand door applications, subject to door and frame preparation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack or Gray factory finish:\u003c\/strong\u003e Select Black for darker openings, or Gray for a neutral appearance; both have the same ECL-600 fire-rated relatching design, alarm and supplied hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating cylinder flexibility:\u003c\/strong\u003e Accepts suitable 5-, 6- or 7-pin conventional or interchangeable-core \u003cstrong\u003erim cylinders\u003c\/strong\u003e; a cylinder collar may be required for some six- or seven-pin configurations. \u003cstrong\u003eOperating cylinder and keys sold separately.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eDetex Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eECL-600 — Black or Gray finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eFire-rated, alarmed, relatching exit control lock with long push bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory Finish\u003c\/th\u003e\n\u003ctd\u003eBlack or Gray, selected in the Finish dropdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire-Hardware Listing\u003c\/th\u003e\n\u003ctd\u003eWarnock Hersey fire exit hardware; up to 3 hours in approved assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Listed Single Door\u003c\/th\u003e\n\u003ctd\u003e4 ft x 8 ft, subject to complete fire-door assembly approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Listed Pair\u003c\/th\u003e\n\u003ctd\u003e8 ft x 8 ft with compatible listed pair-door hardware\/mullion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard Door Width\u003c\/th\u003e\n\u003ctd\u003e36–48 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDeadbolt\u003c\/th\u003e\n\u003ctd\u003e1-inch throw, saw-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLatchbolt\u003c\/th\u003e\n\u003ctd\u003e3\/4-inch deadlocking latchbolt, relatching design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Volume\u003c\/th\u003e\n\u003ctd\u003eApproximately 100 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Power\u003c\/th\u003e\n\u003ctd\u003e9-volt battery, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Reset\u003c\/th\u003e\n\u003ctd\u003eControl key required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHanding\u003c\/th\u003e\n\u003ctd\u003eNon-handed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eCorrosion-resistant alloy lock body, steel push plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExit Sign\u003c\/th\u003e\n\u003ctd\u003eECL-2109 English photoluminescent metal paddle-bar plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Rim Cylinder\u003c\/th\u003e\n\u003ctd\u003eRequired; sold separately (compatible 5–7 pin conventional or IC rim cylinder)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard Included Hardware\u003c\/th\u003e\n\u003ctd\u003eKeeper\/strike kit, cover lock and two keys, push plate and 9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside Lever Trim\u003c\/th\u003e\n\u003ctd\u003eOptional Detex ECL-620, sold separately; lever retracts latchbolt only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFire-rated secondary exits and retail back-of-house openings\u003c\/li\u003e\n\u003cli\u003eWarehouses, distribution centers and loading-area service exits\u003c\/li\u003e\n\u003cli\u003eSchool, healthcare, government and institutional fire exit openings\u003c\/li\u003e\n\u003cli\u003eCommercial facilities seeking relatching and alarmed exit monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial sites requiring mechanical security and positive latching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded with Each ECL-600 Finish\u003c\/h3\u003e\n\u003cp\u003eOne Detex ECL-600 alarmed fire-exit control lock in the \u003cstrong\u003eselected Black or Gray finish\u003c\/strong\u003e with the long operating bar, 1-inch deadbolt and 3\/4-inch deadlocking latchbolt, \u003cstrong\u003e100 dB alarm\u003c\/strong\u003e, \u003cstrong\u003e9V battery\u003c\/strong\u003e, \u003cstrong\u003ecover lock with two cover-lock keys\u003c\/strong\u003e, keeper\/strike kit and English ECL-2109 photoluminescent metal exit warning plate, per the Detex factory package.\u003c\/p\u003e\n\u003ch3\u003eAccessories and Parts Sold Separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRim operating cylinder and operating keys\u003c\/strong\u003e (required; not supplied with this model)\u003c\/li\u003e\n\u003cli\u003eDetex \u003cstrong\u003eECL-445K\u003c\/strong\u003e 5-pin rim cylinder and suitable cylinder-keying options\u003c\/li\u003e\n\u003cli\u003eDetex \u003cstrong\u003eECL-1595\u003c\/strong\u003e collar where needed for applicable 6-\/7-pin cylinders\u003c\/li\u003e\n\u003cli\u003eDetex \u003cstrong\u003eECL-620\u003c\/strong\u003e outside lever trim (lever retracts the latchbolt only)\u003c\/li\u003e\n\u003cli\u003eDetex \u003cstrong\u003eBE-961\u003c\/strong\u003e optional hardwired power conversion kit\u003c\/li\u003e\n\u003cli\u003eDetex \u003cstrong\u003eECL-2100K\u003c\/strong\u003e bar guard, and approved listed mullions\/strikes as needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering and Fire-Door Compliance Notes\u003c\/h3\u003e\n\u003cp\u003eSelect the required \u003cstrong\u003eBlack or Gray finish\u003c\/strong\u003e and verify door width, handing, mounting preparation, strike\/keeper installation, opening fire-rating requirements, permitted key operation, operating rim-cylinder compatibility and the complete fire-door listing. The \u003cstrong\u003eECL-600\u003c\/strong\u003e has a relatching latchbolt in addition to the deadbolt; do not substitute ECL-230D or ECL-230X mechanical details. Install in accordance with current Detex instructions and local fire\/life-safety requirements. Check all supplied components before field work.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Black","offer_id":68050247319767,"sku":"DTX-ECL-600-BLACK","price":691.77,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":68050309152983,"sku":"DTX-ECL-600-GRAY","price":691.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/ECL-600.png?v=1760983259","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-ecl-600-fire-rated-alarmed-exit-control-lock-black","provider":"Commercial Door Worx","version":"1.0","type":"link"}