{"product_id":"detex-fv51-fire-rated-top-rod-exit-device-ea-alarm-fc3-conduit","title":"Detex FV51 Fire-Rated Top Rod Exit | Alarm \u0026 14BN Trim Options","description":"\u003ch2\u003eDetex FV51 Fire-Rated Top-Rod-Only Exit Device | Exit Only, Passage Trim or EA Alarm | 628 \/ 711\u003c\/h2\u003e\u003cp\u003eChoose genuine \u003cstrong\u003eDetex Value Series FV51 fire-rated top-rod-only surface vertical rod exit hardware\u003c\/strong\u003e for properly approved commercial fire-door assemblies. The FV51 uses a \u003cstrong\u003esingle top surface vertical rod and top latch\u003c\/strong\u003e, with \u003cstrong\u003eno bottom rod, floor latch or bottom strike\u003c\/strong\u003e. It is distinct from the FV50 top-and-bottom-rod model. These configurations feature \u003cstrong\u003e628 \/ US28 clear-anodized satin aluminum\u003c\/strong\u003e or \u003cstrong\u003e711 satin-black anodized aluminum\u003c\/strong\u003e, the \u003cstrong\u003e96 surface top strike\u003c\/strong\u003e, and \u003cstrong\u003eLD less dogging\u003c\/strong\u003e to preserve the required positive top latching of approved fire-exit installations.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eAdditional Product Specifications and Ordering Guidance\u003c\/h3\u003e\n\u003ch4\u003eExit Device Configuration, Hardware Schedule and Service\u003c\/h4\u003e\n\u003cp\u003eDetex exit devices must be selected for the complete opening and the intended mechanical, alarm or electrically controlled function. Rim, surface-vertical-rod and top-rod devices have different strike and door\/frame preparation; the full factory SKU controls compatibility.\u003c\/p\u003e\n\u003ch4\u003eModel and Option Identification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAvailable Configuration\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: EA Alarm + FC3 Conduit - 628 Satin Aluminum - 48x84\u003c\/td\u003e\n\u003ctd\u003eDTX-FV51-EA-FC3-LD-628-96-48X84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: No Alarm - No FC3 Conduit - 628 Satin Aluminum - 36x84\u003c\/td\u003e\n\u003ctd\u003eDTX-FV51-LD-628-96-36X84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: No Alarm - No FC3 Conduit - 711 Satin Black Anodized - 36x84\u003c\/td\u003e\n\u003ctd\u003eDTX-FV51-LD-711-96-36X84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration: No Alarm - 14BN Passage Trim - 711 Black Rail \/ 693 Painted Lever - 36x84\u003c\/td\u003e\n\u003ctd\u003eDTX-FV5114BN-LD-711-96-36X84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProduct Selection and Installation Checklist\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm door width, height, handing, stile and the designated Detex series and device length.\u003c\/li\u003e\n\u003cli\u003eMatch the panic\/exit device's latch and strike layout, outside trim, finish and required mechanical dogging state.\u003c\/li\u003e\n\u003cli\u003eReview the approved hardware schedule for fire-rated, windstorm, weatherized, alarmed, delayed-egress or electric-latch-retraction requirements.\u003c\/li\u003e\n\u003cli\u003eIdentify any separate power supply, access-control interface, key cylinder, required mullion or outside trim needed for complete use.\u003c\/li\u003e\n\u003cli\u003eSurface vertical rod and top-rod mechanisms must match the correct head strike, rod path, floor\/threshold latch as applicable, and factory device height. Do not substitute a rim device for a rod assembly.\u003c\/li\u003e\n\u003cli\u003eFor labeled fire exits, retain the complete listed assembly, certified mounting and latching configuration, fire-door-compatible strike and required no-dogging behavior.\u003c\/li\u003e\n\u003cli\u003eEA hardwired alarms, EB battery alarms and EB-W weatherized battery alarms have distinct power and control requirements; select by the specified factory code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAcceptance and Service Verification\u003c\/h4\u003e\n\u003cp\u003eCheck smooth latch engagement, free mechanical emergency exit, authorized dogging and any alarm, electrical release, automatic-door or reset sequences specified for the exact factory model.\u003c\/p\u003e\n\u003ch4\u003eFactory Package and Related Components\u003c\/h4\u003e\n\u003cp\u003eThe selected exit-device assembly and components stated for its factory SKU. Separate controllers, readers, facility keys, field wiring and installation are not automatically included. Consult the original model specifications below when matching the factory SKU to an existing opening.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003cstrong\u003eSelect the correct factory model, function and finish:\u003c\/strong\u003e The standard \u003cstrong\u003eFV51 LD 628 96 36X84\u003c\/strong\u003e and \u003cstrong\u003eFV51 LD 711 96 36X84\u003c\/strong\u003e are \u003cstrong\u003e36-inch, non-alarmed, exit-only fire-rated devices\u003c\/strong\u003e for 84-inch-high doors, with \u003cstrong\u003eno EA\/EB alarm, no FC3 conduit and no outside trim\u003c\/strong\u003e. Choose \u003cstrong\u003e628 satin aluminum\u003c\/strong\u003e or \u003cstrong\u003e711 satin-black anodized aluminum\u003c\/strong\u003e. The new \u003cstrong\u003eFV5114BN LD 711 96 36X84\u003c\/strong\u003e is a \u003cstrong\u003e36-inch, non-alarmed fire-rated FV51\u003c\/strong\u003e for the same 84-inch door height, but \u003cstrong\u003eincludes Detex Function 14 BN passage S-lever outside trim\u003c\/strong\u003e. Its exit-device rail is \u003cstrong\u003e711 satin-black anodized\u003c\/strong\u003e and its BN lever trim is \u003cstrong\u003e693 \/ SPBLK black painted\u003c\/strong\u003e. \u003cstrong\u003eFunction 14 is always active and requires no cylinder or key.\u003c\/strong\u003e The \u003cstrong\u003eFV51 EA FC3 LD 628 96 48X84\u003c\/strong\u003e is the separate \u003cstrong\u003e48-inch, EA hardwired-alarm device\u003c\/strong\u003e in 628 satin aluminum with the requested \u003cstrong\u003eFC3 3-foot flexible-conduit option\u003c\/strong\u003e; confirm FC3 contents with the factory. All listed models use \u003cstrong\u003eLD less dogging\u003c\/strong\u003e and the \u003cstrong\u003e96 surface top strike\u003c\/strong\u003e. Choose carefully based on the door size, finish and alarm\/outside-entry needs.\u003c\/p\u003e\u003ch3\u003eAvailable Models and Operating Differences\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFactory Model\u003c\/th\u003e\n\u003cth\u003eAlarm \/ Electrical Package\u003c\/th\u003e\n\u003cth\u003eDoor Size and Function\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV51 LD 628 96 36X84\u003c\/strong\u003e\u003cp\u003eSKU DTX-FV51-LD-628-96-36X84\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eStandard \/ No Alarm:\u003c\/strong\u003e Mechanical exit-only device without an EA hardwired alarm, 9V exit-alarm electronics or FC3 conduit. Does \u003cstrong\u003enot\u003c\/strong\u003e require power to permit normal inside egress.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e36-inch device for 84-inch door\u003c\/strong\u003e (3'0\" x 7'0\"); fire-rated top-rod-only SVR; less dogging; 96 surface top strike; 628 satin aluminum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV51 EA FC3 LD 628 96 48X84\u003c\/strong\u003e\u003cp\u003eSKU DTX-FV51-EA-FC3-LD-628-96-48X84\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEA Hardwired Exit Alarm:\u003c\/strong\u003e Audible exit alarm with external \u003cstrong\u003e12–24V AC\/DC\u003c\/strong\u003e wiring capability and the requested \u003cstrong\u003eFC3 3-foot flexible conduit\u003c\/strong\u003e. Verify FC3 kit and fittings on the factory order.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e48-inch device for 84-inch door\u003c\/strong\u003e (4'0\" x 7'0\"); fire-rated top-rod-only SVR; less dogging; 96 surface top strike; 628 satin aluminum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV51 LD 711 96 36X84\u003c\/strong\u003e\u003cp\u003eSKU DTX-FV51-LD-711-96-36X84\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eStandard \/ No Alarm:\u003c\/strong\u003e Mechanical exit-only device in \u003cstrong\u003e711 \/ DC35 Satin Black Anodized Aluminum\u003c\/strong\u003e. No EA hardwired alarm, 9V alarm electronics, FC3 conduit or outside operating trim. No electrical power is needed for ordinary inside egress.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e36-inch device for 84-inch door\u003c\/strong\u003e (3 ft x 7 ft); fire-rated top-rod-only SVR; less dogging; 96 surface top strike; \u003cstrong\u003e711 satin-black anodized finish\u003c\/strong\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV5114BN LD 711 96 36X84\u003c\/strong\u003e\u003cp\u003eSKU DTX-FV5114BN-LD-711-96-36X84\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNo Alarm — 14BN Passage Lever Trim Included:\u003c\/strong\u003e 711 satin-black anodized FV51 rail with \u003cstrong\u003e693 \/ SPBLK black-painted BN narrow S-lever trim\u003c\/strong\u003e. \u003cstrong\u003eBHMA Function 14:\u003c\/strong\u003e exterior lever always active; \u003cstrong\u003eno operating cylinder or keys\u003c\/strong\u003e.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e36-inch device for an 84-inch door\u003c\/strong\u003e (3 ft × 7 ft); fire-rated top-rod-only SVR; LD less dogging, 96 top surface strike. Outside passage trim is included, unlike the exit-only models.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e \"LD\" means \u003cstrong\u003eless\/no dogging\u003c\/strong\u003e, which does not permit the fire-exit latch to be held mechanically retracted. \u003cstrong\u003eEA\u003c\/strong\u003e specifies the hardwired audible exit alarm; \u003cstrong\u003eFC3\u003c\/strong\u003e specifies a 3-foot flexible conduit. The \u003cstrong\u003e36-inch standard FV51 LD\u003c\/strong\u003e models in 628 or 711 have \u003cstrong\u003eneither EA nor FC3\u003c\/strong\u003e. None of these devices is a delayed-egress model. \u003cstrong\u003eOnly the FV5114BN package includes outside trim\u003c\/strong\u003e, a \u003cstrong\u003eFunction 14 always-active, no-cylinder BN passage lever\u003c\/strong\u003e; the three standard FV51 LD \/ EA FC3 models are exit-only and have no included outside trim.\u003c\/p\u003e\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetex FV51 fire-exit series:\u003c\/strong\u003e Fire-rated version of the Value Series V51 top-rod-only exit-device family. Suitable for the properly listed commercial fire-door assembly, with manufacturer fire listings supporting certain metal doors up to 3 hours when the entire assembly is approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop-rod-only latching:\u003c\/strong\u003e Pressing the inside touchbar releases the approved \u003cstrong\u003esingle top vertical rod latch\u003c\/strong\u003e. There is \u003cstrong\u003eno bottom rod or bottom bolt\u003c\/strong\u003e; do not order or install a V50 bottom-latching arrangement by mistake.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory 96 surface top strike:\u003c\/strong\u003e The \u003cstrong\u003e96\u003c\/strong\u003e code specifies the surface strike configuration. Verify the exact manufacturer strike\/installation template and frame preparation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess dogging (LD):\u003c\/strong\u003e Factory no-dogging function supports positive latching on a fire-exit opening. Fire-rated doors must not be dogged or modified in ways that defeat latching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose 628 Satin Aluminum or 711 Satin Black Anodized:\u003c\/strong\u003e \u003cstrong\u003e628 \/ US28\u003c\/strong\u003e is clear-anodized satin aluminum on the standard 36-inch and EA 48-inch device rails. \u003cstrong\u003e711 \/ DC35\u003c\/strong\u003e is satin-black anodized aluminum on the standard 36-inch exit-only rail and the new \u003cstrong\u003eFV5114BN\u003c\/strong\u003e rail. The \u003cstrong\u003e14BN S-lever outside trim is 693 \/ SPBLK Black Painted\u003c\/strong\u003e, not 711 black anodized. Match each component's finish to the opening's hardware schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36-inch non-alarmed configurations:\u003c\/strong\u003e \u003cstrong\u003eFV51 LD 628\u003c\/strong\u003e and \u003cstrong\u003eFV51 LD 711\u003c\/strong\u003e are \u003cstrong\u003eexit-only\u003c\/strong\u003e, whereas \u003cstrong\u003eFV5114BN LD 711\u003c\/strong\u003e includes the \u003cstrong\u003ealways-active 14BN outside passage trim\u003c\/strong\u003e. All three fit appropriately approved \u003cstrong\u003e36-inch-wide by 84-inch-high\u003c\/strong\u003e doors. No audible alarm, electrical wiring, alarm power supply or flexible alarm conduit is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48-inch EA alarm configuration:\u003c\/strong\u003e\u003cstrong\u003eFV51 EA FC3 LD 628 96 48X84\u003c\/strong\u003e is intended for a \u003cstrong\u003e48-inch-wide by 84-inch-high\u003c\/strong\u003e door and includes the factory-designated \u003cstrong\u003eEA audible exit alarm\u003c\/strong\u003e with hardwired control provisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEA power and alarm control:\u003c\/strong\u003e The EA option supports external \u003cstrong\u003e12–24V AC\/DC\u003c\/strong\u003e supply and remote alarm\/bypass connections according to Detex EA wiring instructions. Manufacturer EA literature also provides for a 9V battery and piezo horn with red\/green arming indicators. Confirm exact controller, battery, cylinder and power-supply details against the factory package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC3 wiring transfer:\u003c\/strong\u003e On the \u003cstrong\u003eEA FC3 48-inch model only\u003c\/strong\u003e, the FC3 designation calls for \u003cstrong\u003e3 feet of flexible conduit\u003c\/strong\u003e for routing the electrical connection. Verify that the included conduit and fittings match the manufacturer's final order and door arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade installation:\u003c\/strong\u003e Detex Value Series uses an extruded-aluminum rail and manufacturer mounting\/strike locator provisions. Check the latest Detex fire-exit mounting instructions before field preparation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory 14BN passage trim — FV5114BN only:\u003c\/strong\u003e The complete package includes Detex's \u003cstrong\u003eBN narrow-escutcheon S-lever\u003c\/strong\u003e in \u003cstrong\u003e693 black painted\u003c\/strong\u003e. \u003cstrong\u003eBHMA Function 14\u003c\/strong\u003e provides a normally active outside lever to retract the latch without a key. The escutcheon is \u003cstrong\u003eblank\u003c\/strong\u003e, with no mortise-cylinder preparation. This option is for openings where unkeyed exterior reentry is permitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside trim selection:\u003c\/strong\u003e Three variants are \u003cstrong\u003einterior exit-device-only\u003c\/strong\u003e packages and require compatible outside trim purchased separately where external entry is needed. \u003cstrong\u003eFV5114BN\u003c\/strong\u003e includes the specific \u003cstrong\u003e14BN passage S-lever outside trim\u003c\/strong\u003e; it does not include any alarm or lockable cylinder function.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eDetex Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eValue Series FV51, fire-rated top-rod-only surface vertical rod exit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable Models\u003c\/th\u003e\n\u003ctd\u003eFV51 LD 628 96 36X84; FV51 LD 711 96 36X84; FV51 EA FC3 LD 628 96 48X84; \u003cstrong\u003eFV5114BN LD 711 96 36X84\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Type\u003c\/th\u003e\n\u003ctd\u003eFire-rated FV51 top-rod-only surface vertical rod exit device; select \u003cstrong\u003eexit-only or factory-included 14BN passage trim\u003c\/strong\u003e configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRod and Latch Arrangement\u003c\/th\u003e\n\u003ctd\u003eSingle \u003cstrong\u003etop rod and top latch\u003c\/strong\u003e; no bottom rod, bottom latch or floor strike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard Non-Alarm Models\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV51 LD 628 96 36X84\u003c\/strong\u003e or \u003cstrong\u003eFV51 LD 711 96 36X84\u003c\/strong\u003e — 36-inch exit device for 84-inch-high door, no exit alarm or FC3 conduit; choose 628 satin aluminum or 711 satin black anodized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardwired Alarm Model\u003c\/th\u003e\n\u003ctd\u003eFV51 EA FC3 LD 628 96 48X84 — \u003cstrong\u003e48-in. device for 84-in.-high door\u003c\/strong\u003e, EA hardwired exit alarm plus FC3 3-ft conduit designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e14BN Passage Trim Package\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV5114BN LD 711 96 36X84\u003c\/strong\u003e: 36-inch exit device \/ 84-inch door, no exit alarm, included 14BN S-lever passage trim. \u003cstrong\u003e711 anodized device rail \/ 693 black-painted outside trim\u003c\/strong\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDogging\u003c\/th\u003e\n\u003ctd\u003eLD — less dogging \/ no latch hold-back on \u003cstrong\u003eall configurations\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStrike\u003c\/th\u003e\n\u003ctd\u003e96 — surface top strike, verify final factory packing list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e628 \/ US28 Satin Aluminum, Clear Anodized\u003c\/strong\u003e (36-inch standard and 48-inch EA); \u003cstrong\u003e711 \/ DC35 Satin Black Anodized Aluminum\u003c\/strong\u003e (36-inch standard exit only or FV5114BN with passage trim). \u003cstrong\u003e14BN lever trim: 693 \/ SPBLK Black Painted\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm — Standard 36-in. Model\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNone for FV51 LD 628, FV51 LD 711 or FV5114BN LD 711.\u003c\/strong\u003e No exit-alarm electronics, alarm battery or hardwired power requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm — EA 48-in. Model\u003c\/th\u003e\n\u003ctd\u003eEA — hardwired audible exit alarm for exit-activation monitoring; external 12–24V AC\/DC capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEA Control and Battery\u003c\/th\u003e\n\u003ctd\u003eEA option includes factory-specified alarm controls and 9V battery provision; check manufacturer wiring and arming instructions. Only applicable to EA version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlexible Conduit\u003c\/th\u003e\n\u003ctd\u003eFC3 — 3-ft conduit on \u003cstrong\u003eEA 48-in. variant only\u003c\/strong\u003e; confirm fittings and inclusion on supplier order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire Listing\u003c\/th\u003e\n\u003ctd\u003eManufacturer-listed FV51 fire-exit hardware for compatible fire door assemblies; ratings up to 3 hours for qualifying metal openings. Check exact listing, door and AHJ requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHanding\u003c\/th\u003e\n\u003ctd\u003eUse manufacturer-approved factory handing\/rehanding and fire-exit installation instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside Trim\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV5114BN LD 711 includes factory 14BN Function 14 passage S-lever exterior trim.\u003c\/strong\u003e Other variants do not include outside trim; select separately where needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e14BN Operating Function\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBHMA Function 14 — always-active outside S-lever passage\u003c\/strong\u003e. No operating mortise cylinder, key or keyed lock function required. Blank narrow escutcheon. Confirm correct handed mounting per Detex FV5114BN templates.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShopify Shipping Weight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e25 lb provisional for exit-device-only variants\u003c\/strong\u003e; \u003cstrong\u003e30 lb provisional for FV5114BN with supplied 14BN trim\u003c\/strong\u003e. These are shipping-setting estimates, not factory-verified packed weights. Check carton weight and dimensions before calculating parcel or freight charges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSelect the Correct FV51 Configuration\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eStandard non-alarmed FV51 LD 628 or 711 96 36X84:\u003c\/strong\u003e Choose when the door schedule requires fire-rated \u003cstrong\u003etop-only latching\u003c\/strong\u003e without an audible alarm or electrical wiring. Both 36-inch devices are exit-only and include \u003cstrong\u003eno FC3 conduit\u003c\/strong\u003e. Select \u003cstrong\u003e628 Satin Aluminum\u003c\/strong\u003e or \u003cstrong\u003e711 Satin Black Anodized\u003c\/strong\u003e to match the hardware schedule. A compatible outside trim must be purchased separately if keyed or lever-controlled entry is desired.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFV5114BN LD 711 96 36X84 — Passage S-Lever Included:\u003c\/strong\u003e Select this fire-rated, 36-inch FV51 top-rod-only exit device when an approved opening requires \u003cstrong\u003ealways-active outside passage by lever\u003c\/strong\u003e without a key or cylinder. Its \u003cstrong\u003e711 black-anodized exit rail\u003c\/strong\u003e is supplied with a \u003cstrong\u003e693 black-painted 14BN narrow S-lever\u003c\/strong\u003e. It remains non-alarmed and does not use FC3 conduit. \u003cstrong\u003eDo not select Function 14 for doors where exterior access must remain locked.\u003c\/strong\u003e Confirm factory handing, fire-rating compatibility and the mounting plate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEA\/FC3 alarmed FV51 EA FC3 LD 628 96 48X84:\u003c\/strong\u003e Choose for a wider 48-inch opening where an audible alarm should alert personnel that a monitored exit has been used. EA alarm power and wiring must be installed to Detex specifications, and the requested FC3 conduit package should be confirmed with the distributor. Alarm operation must \u003cstrong\u003enot\u003c\/strong\u003e obstruct free egress.\u003c\/p\u003e\u003ch3\u003eTypical Commercial Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFire-rated exit-only service openings using a manufacturer-approved single top vertical latch\u003c\/li\u003e\n\u003cli\u003eSchools, offices, hospitals and municipal facilities needing properly listed fire-exit hardware\u003c\/li\u003e\n\u003cli\u003eWarehouses, industrial facilities and institutional service exits\u003c\/li\u003e\n\u003cli\u003eEA model: fire-exit doors requiring audible exit monitoring and wiring transfer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's Included\u003c\/h3\u003e\u003cp\u003eOne \u003cstrong\u003eDetex FV51 fire-rated top-rod-only exit-device assembly\u003c\/strong\u003e in the selected size\/function\/finish, with manufacturer-supplied standard mounting and strike parts for its exact factory model. The \u003cstrong\u003e36-inch standard FV51 LD models\u003c\/strong\u003e in 628 or 711 are non-alarmed and are \u003cstrong\u003eexit-only (no outside trim)\u003c\/strong\u003e. The \u003cstrong\u003e36-inch FV5114BN LD 711\u003c\/strong\u003e is non-alarmed but \u003cstrong\u003eincludes its 14BN Function 14 passage S-lever exterior trim in 693 black painted\u003c\/strong\u003e. The \u003cstrong\u003e48-inch EA FC3\u003c\/strong\u003e model has the EA alarm with specified FC3 wiring option, but no outside lever trim. Confirm final packing contents, including conduit fittings, alarm parts, batteries, mounting fasteners and strikes, using the manufacturer's order confirmation and packing list.\u003c\/p\u003e\u003ch3\u003eSold Separately\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eExterior pull\/lever\/cylinder trim and keys for the three device-only configurations\u003c\/strong\u003e where external entry is required; door, frame, any required throughbolts or special retrofit accessories, and installation labor. The \u003cstrong\u003eFV5114BN includes the 14BN outside passage S-lever\u003c\/strong\u003e and has \u003cstrong\u003eno keyed operating cylinder or keys\u003c\/strong\u003e because Function 14 does not require them. On \u003cstrong\u003eEA configurations only\u003c\/strong\u003e, confirm whether a separate key-control cylinder, external building power supply, electrical interface or other controls are required and provided in the factory kit. The \u003cstrong\u003estandard non-EB\/non-EA FV51 LD\u003c\/strong\u003e requires none of these alarm components.\u003c\/p\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003cp\u003eShopify carrier settings are \u003cstrong\u003e25 lb provisional for the three FV51 exit-device-only variants\u003c\/strong\u003e and \u003cstrong\u003e30 lb provisional for the FV5114BN passage-trim package\u003c\/strong\u003e to allow for the additional lever assembly. \u003cstrong\u003eNeither weight is verified for the exact shipped carton.\u003c\/strong\u003e Confirm actual weight and dimensions before calculating rates; these models have differing lengths and contents. Large exit-device cartons may require special parcel or freight handling.\u003c\/p\u003e\u003ch3\u003eOrdering, Installation and Life-Safety Requirements\u003c\/h3\u003e\u003cp\u003eConfirm \u003cstrong\u003e36 vs. 48 inch device length\u003c\/strong\u003e, \u003cstrong\u003e628 satin-aluminum vs. 711 satin-black anodized device finish\u003c\/strong\u003e, \u003cstrong\u003e693 black-painted 14BN trim on FV5114BN\u003c\/strong\u003e, \u003cstrong\u003eexit-only vs. always-active passage trim vs. EA hardwired alarm\u003c\/strong\u003e, \u003cstrong\u003eFC3 conduit (EA variant only)\u003c\/strong\u003e, 84-inch door height, correct 96 surface strike, door handing and manufacturer-approved installation pattern. For the separate EA\/FC3 model, confirm the FC3 conduit package against Detex's full \u003cstrong\u003eFV51 EA FC3 LD 628 96 48X84\u003c\/strong\u003e factory order. For \u003cstrong\u003eFV5114BN\u003c\/strong\u003e, verify the Function 14 trim is approved for the opening, the factory handing is correct and the black-painted BN trim is supplied with the required mounting components. Maintain unrestricted egress and positive top latching. Never add mechanical dogging, an unauthorized bottom-latching modification or any other changes that compromise the door's fire listing. Follow the latest Detex installation and alarm instructions and the authority having jurisdiction.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"EA Alarm + FC3 Conduit - 628 Satin Aluminum - 48x84","offer_id":68054539567319,"sku":"DTX-FV51-EA-FC3-LD-628-96-48X84","price":1346.58,"currency_code":"USD","in_stock":true},{"title":"No Alarm - No FC3 Conduit - 628 Satin Aluminum - 36x84","offer_id":68054573121751,"sku":"DTX-FV51-LD-628-96-36X84","price":968.97,"currency_code":"USD","in_stock":false},{"title":"No Alarm - No FC3 Conduit - 711 Satin Black Anodized - 36x84","offer_id":68054623420631,"sku":"DTX-FV51-LD-711-96-36X84","price":968.97,"currency_code":"USD","in_stock":false},{"title":"No Alarm - 14BN Passage Trim - 711 Black Rail \/ 693 Painted Lever - 36x84","offer_id":68054627549399,"sku":"DTX-FV5114BN-LD-711-96-36X84","price":1239.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/DTX_V51LD_628.png?v=1794513575","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-fv51-fire-rated-top-rod-exit-device-ea-alarm-fc3-conduit","provider":"Commercial Door Worx","version":"1.0","type":"link"}