- Manufacturer and part number on the existing component
- Door or operator model, plus size and finish where applicable
- Mounting style, handedness, and electrical specifications when relevant
Detex MS-2049 Form C Magnetic Switch | Flush, Surface, Conduit or Inswing
Replacement part details
The part number updates with your selected option. Confirm the size, finish, and configuration before ordering.
Check the specifications below for compatibility, then confirm your original part number and equipment details before ordering. Contact our parts team if you need help.
Detex MS-2049 Form C Magnetic Switch | Flush, Surface, Conduit or Inswing
Detex MS-2049 Form C Magnetic Switch | Flush, Surface, Conduit or Inswing
$226.00
$211.99
/
Buying several replacement parts? Choose the quantity, add this item to your cart, and continue shopping parts.
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Detex MS-2049 Heavy-Duty Form C Magnetic Door Switch | Flush, Surface, Conduit or Inswinging
Monitor the open/closed condition of compatible commercial doors using the Detex MS-2049 Heavy-Duty Magnetic Door Switch. This family of Form C / SPDT magnetic door contacts detects door movement and provides a dry-contact signal to approved exit alarms, access-control systems and remote monitoring equipment. Choose the correct factory mounting configuration: MS-2049F flush mount, MS-2049S standard surface mount, MS-2049SC surface mount with a thin-wall conduit connector, or MS-2049SI surface mount specifically for inswinging doors. Each uses manufacturer-specified color-coded leads, a 500mA at 24VDC maximum contact rating, and a compatible door-mounted magnet.
Additional Product Specifications and Ordering Guidance
Form-C Contact Selection and Door Position Monitoring
This Detex magnetic-switch family is available with different physical mountings and cable/conduit orientations. A form-C switch provides changeover contact behavior suitable for the monitoring circuit specified by the manufacturer; it does not independently lock or alarm the door.
Model and Option Identification
| Available Configuration | SKU |
|---|---|
| Mounting Style: Flush Mount | DTX-MS-2049F |
| Mounting Style: Surface Mount | DTX-MS-2049S |
| Mounting Style: Surface Mount with Thin-Wall Conduit Connector | DTX-MS-2049SC |
| Mounting Style: Surface Mount for In-Swinging Doors | DTX-MS-2049SI |
Product Selection and Installation Checklist
- Select the exact flush, surface, conduit or inswinging configuration by SKU and match the installed magnet and switch alignment.
- Confirm the switch contact form, maximum electrical ratings and intended panel input using the model's current wiring sheet.
- Check door/frame clearance, operating gap, magnet orientation, cable routing and whether the environment requires additional sealing.
- Identify any required wiring accessories, installation fasteners and separately ordered magnet kits.
Acceptance and Service Verification
Open and close the door through normal travel and measure contact changeover at the controller; confirm reliable reset and correct event display.
Factory Package and Related Components
The selected switch/contact assembly, with factory accessories only as stated for its specific SKU. Controller and field wiring are separate. Consult the original model specifications below when matching the factory SKU to an existing opening.
New MS-2049SC conduit-mount option: The Detex MS-2049SC is the surface-mounted contact configuration with a factory conduit connector intended for thin-wall electrical conduit. The magnet and its mounting bracket attach to the door; the switch/contact assembly, cover, conduit adapter and connector attach at the frame. This model is suited to installations where the contact lead must enter an approved conduit pathway, unlike the plain MS-2049S surface model. The connector is included, but a length of field-supplied conduit is not automatically included. Use Detex installation instructions INS-2049SC-3429 and verify conduit routing, bracket clearance and fastening.
MS-2049SI for inswinging doors: The new Detex MS-2049SI is the heavy-duty Form C magnetic switch designed for inward-opening commercial doors. Unlike the standard surface model, the SI contact and magnet use the factory inswing-specific surface mounting arrangement to suit an inswing door and frame. The sensor uses a Form C / SPDT dry contact, 12-inch color-coded concealed leads, and high-impact thermoplastic surface housing, with a maximum contact load of 500mA at 24VDC. Use the separate INS-2049SI-3430 installation instructions and verify actual swing, mounting clearances and contact alignment before ordering.
Important: The MS-2049 family consists of passive door-position switches. These products do not include an audible alarm, battery, power supply, electric lock or exit device. A compatible alarm or monitoring panel is required to process the Form C contact signal and provide any notification.
Compare the Available Mounting Styles
| Detex Model and SKU | Mounting and Included Features | Shipping |
|---|---|---|
|
MS-2049F — Flush Mount SKU DTX-MS-2049F |
Concealed flush-mounted contact: switch recessed in door frame and magnet mortised into edge of door. Factory flush plates and 12-inch color-coded wiring leads. Requires appropriate frame/door mortising and manufacturer-approved clearances. | 0.75 lb distributor-listed Shopify shipping weight, unchanged. Verify packed carton dimensions. |
|
MS-2049S — Surface Mount SKU DTX-MS-2049S |
Standard surface-mounted contact: high-impact ABS switch cover installed at frame; mating magnet and bracket attach on door surface. 12-inch color-coded leads. No FC-style conduit connector specified for this SKU. | 1.1 lb provisional Shopify weight from retailer product-weight data. Verify packed carton dimensions and weight. |
|
MS-2049SC — Surface Mount with Conduit Connector SKU DTX-MS-2049SC |
Conduit-ready surface-mounted contact: switch housing, mounting cover, door magnet/bracket, thin-wall conduit connector and adapter, and 12-inch color-coded leads. Form C / SPDT contact. Connector permits suitable electrical-conduit entry; separate conduit run is field-supplied. | 1.5 lb retailer-listed shipping weight for exact model. Product dimensions listed by Grainger: approximately 5-3/16 × 3-1/2 × 1-1/4 inches. These are not verified carton dimensions. |
|
MS-2049SI — Inswinging Surface Mount SKU DTX-MS-2049SI |
Surface-mounted Form C door-position sensor specifically for inward-opening doors. Factory inswing-compatible contact and magnet/mounting configuration with durable high-impact ABS housing and 12-inch color-coded leads. Does not include the MS-2049SC thin-wall conduit connector. Install to the model-specific Detex INS-2049SI-3430 template. | 1.1 lb provisional Shopify weight, estimated from comparable MS-2049S surface-mount hardware. Actual SI packed weight and carton dimensions have not been verified. |
Which configuration to order: Choose F for recessed/flush installations, S for standard surface-mount wiring, SC when a thin-wall conduit connector is required, or SI when the monitored door is inswinging and requires Detex's dedicated surface-mount geometry. Do not substitute a different mounting model without reviewing the applicable door/frame template.
Key Features and Benefits
- Heavy-duty Detex OEM design: Commercial-door magnetic switch family designed to help detect unapproved opening, doors left ajar, or an open/closed door-position condition.
- Form C / SPDT output: Provides common, normally open and normally closed switching connections for suitable low-voltage monitoring inputs; wiring must follow the exact device contact diagram.
- Rated 24VDC at 0.5A: Detex documents a maximum dry-contact rating of 500 milliamps at 24 volts. This rating is for the switch contact and does not mean the sensor itself supplies 24VDC power.
- Color-coded 12-inch wire leads: Manufacturer standard leads for installation and wiring to approved security, exit-alarm and monitoring circuits.
- MS-2049SC conduit connector: A surface-mount connector and reversible adapter intended for thin-wall conduit. When locating the device near the latch side, permit adequate clearance for conduit; Detex notes the adapter can be reversed to bring conduit in from the hinge side.
- MS-2049SI inswinging option: Dedicated surface-mounted contact/magnet arrangement for inward-swinging commercial doors, with high-impact ABS protective housing. Designed for appropriate steel, aluminum and wood door/frame applications.
- Standard MS-2049S surface option: Contact and magnet assembly supplied with high-impact ABS protective covers for frame and door surface mounting, without the SC conduit entry configuration.
- MS-2049F concealed option: Contact recessed into a properly prepared frame and magnet mortised into the door edge for applications where surface housings are undesirable.
- Durability for active commercial doors: Potted switch components resist ordinary shock and moisture exposure under manufacturer-specified conditions; surface-mounted units use protective high-impact ABS housings.
- More than one million loaded cycles: Detex literature specifies more than one million switch operations under load.
- Tamper-resistant mounting: Mounting screws are not accessible while the door is properly closed, which reduces opportunities for unintended removal.
- Steel, aluminum or wood doors: Manufacturer-approved door/frame surfaces; consult Detex templates for stiles as narrow as 1-3/8 inches and applicable installation clearances.
- Compatible monitoring applications: Trigger a manufacturer-compatible Detex EAX-2500 exit alarm, remote status display, security-panel input or related door-monitoring arrangement after contact and wiring compatibility are confirmed.
- Fire-door accessory applications: MS-2049F, S and SC have been listed by Detex as UL-Classified Miscellaneous Fire Door Accessories; the installation must still meet the door assembly listing and permitted field preparations.
- Three-year limited manufacturer warranty: Subject to current Detex warranty terms and correct installation.
Technical Specifications
| Manufacturer | Detex Corporation |
|---|---|
| Series | MS-2049 Heavy-Duty Magnetic Switch |
| Models Available | MS-2049F — Flush; MS-2049S — Surface; MS-2049SC — Surface / Conduit Connector; MS-2049SI — Inswinging Surface Mount |
| Primary Function | Dry-contact sensing of door-open or door-closed magnetic condition |
| Contact Type | Form C, SPDT (single-pole, double-throw) |
| Maximum Contact Load | 0.5A / 500mA at 24VDC |
| Wiring | 12-inch color-coded leads; confirm contact functions in factory diagram |
| MS-2049F Mounting | Flush/recessed contact in frame, magnet mortised in door edge |
| MS-2049S Mounting | Surface-mounted contact and magnet/bracket with protective high-impact ABS covers |
| MS-2049SI Mounting | Surface mount for inswinging doors; factory model-specific door/frame geometry and aligned magnet/contact, with high-impact ABS protective case |
| MS-2049SI Contact | Form C / SPDT, 12-inch concealed color-coded leads, 0.5A at 24VDC maximum contact rating |
| MS-2049SC Mounting | Surface-mounted contact and magnet with thin-wall conduit connector and adapter |
| MS-2049SC Connector | Conduit connector specified for thin-wall conduit; use approved conduit size, fit and wiring pathway per INS-2049SC-3429 |
| MS-2049SC Connector Routing | Install with correct clearance at latch side; Detex describes a reversible conduit adapter for hinge-side approach |
| MS-2049SC Reference Dimensions | Grainger catalog overall: approximately 5-3/16 in long × 3-1/2 in wide × 1-1/4 in high. Verify installation outline with Detex's current factory template. |
| MS-2049F Faceplate | Approximate flush plate 1-1/4 × 4-7/8 inches per model drawing; verify installation template |
| Magnet to Contact Location | Position so door opening greater than 2 inches produces the connected alarm condition, per Detex SC installation instructions |
| MS-2049F Max Misalignment | Existing flush-model instructions specify approximately 1/8 inch; use model-specific alignment requirements rather than transferring this tolerance to SC |
| Durability | More than one million operations under load per Detex literature |
| Door and Frame Materials | Manufacturer-approved steel, aluminum and wood |
| Narrow-Stile Applications | Detex states models may be installed on stiles as narrow as 1-3/8 inches, subject to hardware and template constraints |
| Fire Door Use | MS-2049 family has manufacturer literature describing fire-door accessory uses. MS-2049SI's exact model/assembly fire-door listing must be independently confirmed before use on a rated opening; comply with approved preparations and local authority requirements |
| External Alarm | Not included; compatible security/exit-alarm monitoring equipment required for audible or remote alerts |
| MS-2049F Instructions | INS-2049F-3427 |
| MS-2049S Instructions | INS-2049S-3428 |
| MS-2049SC Instructions | INS-2049SC-3429 |
| MS-2049SI Instructions | INS-2049SI-3430, surface magnetic switch for inswing doors |
| MS-2049F Shipping Weight | 0.75 lb existing Shopify setting from distributor-listed data |
| MS-2049S Shipping Weight | 1.1 lb provisional Shopify setting pending exact carton verification |
| MS-2049SC Shipping Weight | 1.5 lb, Grainger-listed shipping weight for exact MS-2049SC model |
| MS-2049SI Shipping Weight | 1.1 lb provisional estimate based on comparable MS-2049S surface assembly; not a confirmed manufacturer/distributor packed weight |
| Shipping Carton Dimensions | Not verified for F, S, SC or SI; do not substitute switch body size for packed carton |
| Warranty | Detex 3-year limited warranty, subject to current manufacturer terms |
Commercial Applications
- Detex EAX-2500 and compatible exit-alarm systems requiring a door position input
- Warehouse, stockroom, retail, healthcare, education and office door-position monitoring
- Surface-mounted installations using thin-wall conduit for low-voltage security wiring (MS-2049SC)
- Monitoring of commercial inswinging doors requiring the model-specific MS-2049SI surface-mount arrangement
- Door monitoring in compatible listed fire-door openings with approved contact mounting
- Door-forced-open and held-open conditions reported through a separately supplied control panel
What's Included
One selected Detex MS-2049 factory switch assembly, the corresponding door magnet and required manufacturer-standard mounting components and 12-inch color-coded wire leads. MS-2049F is flush-mounted; MS-2049S includes the standard surface-contact and magnet housings; MS-2049SC includes the model-specific surface contact, protective housing, magnet/bracket, thin-wall conduit connector and reversible adapter. MS-2049SI supplies the inswing-specific surface magnetic contact and mating magnet assembly with standard factory hardware and 12-inch leads. Confirm replacement fasteners, exact mounting-bracket contents and all accessories against the current Detex packing list.
Sold Separately
Alarm or monitoring controller, Detex EAX-2500 or other exit alarm, security-panel power source, extension wiring, door and frame, any actual run of thin-wall electrical conduit for the SC connector, approved field conduit fittings not included with the switch, and installation labor. Field-supplied inswing-specific shims or specialty anchors not included by the factory should be purchased separately.
Shipping Information
MS-2049F flush mount: 0.75 lb (existing Shopify shipping weight). MS-2049S surface mount: 1.1 lb provisional retailer weight. MS-2049SC surface/conduit mount:1.5 lb Grainger-listed shipping weight for exact model. MS-2049SI inswinging surface mount: 1.1 lb provisional estimate based on comparable surface-mount unit (not a verified SI packaged shipping weight). Manufacturer-packed box dimensions have not been independently verified; compare distributor-packed weights and measurements with actual warehouse cartons before buying UPS labels.
Installation and Life-Safety Notes
Use the manufacturer's model-specific installation instructions: INS-2049F-3427 for F, INS-2049S-3428 for S, INS-2049SC-3429 for the conduit connector, or INS-2049SI-3430 for the inswinging model. The MS-2049SC is intended for thin-wall conduit and must allow adequate space for the connector. The MS-2049SI must be installed with the dedicated inswinging mounting template; do not assume S/SC mounting geometry is appropriate for inward-swinging doors. Detex notes that its adapter is reversible to bring conduit from the hinge-side if required. Keep the contact and magnet aligned so a door cannot open more than two inches without creating the expected signal to the connected alarm. The contact is rated 500mA at 24VDC maximum; do not connect high-current security loads directly. On fire-rated doors, verify the exact factory model's approval, particularly the SI variant, and use only permitted preparations consistent with the door listing and authority having jurisdiction. This component senses door status but does not independently lock, power, alarm or delay egress.
Recently viewed products
Describe your recently viewed products here