{"product_id":"detex-sifv-ea-cd-48-hardwired-exit-alarm-filler-kit","title":"Detex SIFV-EA-CD-48 Value Series Slide-In Filler Kit – 48\" (No Cylinder)","description":"\u003ch1 data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eDetex SIFV-EA-CD-48 Value Series Slide-In Filler Kit – 48\"\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHardwired Exit Alarm | Cylinder Dogging | 48\" Value Series Device | Cylinder Not Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUpgrade or repair a compatible Detex Value Series exit device with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex SIFV-EA-CD-48 Slide-In Filler Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e48\" Detex Value Series exit devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this filler assembly adds the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEA hardwired exit-alarm function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with pushpad monitoring, remote signaling, remote bypass capability, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecylinder dogging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen an unauthorized exit attempt is made, the EA system activates an approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 dB alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping alert facility personnel while maintaining normal life-safety egress operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex Value Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e replacement component\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel: SIFV-EA-CD-48\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e48\" devices\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHardwired \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEA Exit Alarm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 dB audible alarm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCylinder Dogging (CD)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePushpad monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote signal capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote bypass input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisual and audible arming indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/8-turn cylinder dogging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAllows authorized bypass and alarm control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSlide-in filler design simplifies service and retrofit work\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible Detex Value Series exit devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMortise cylinder not included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHardwired Exit Alarm\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e option is intended for doors requiring a hardwired alarmed panic device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the pushpad is activated while the system is armed, the approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 dB alarm sounds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to alert personnel of an unauthorized exit attempt.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe EA system also provides:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote alarm signaling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote bypass\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePushpad monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eArmed\/disarmed indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKey-controlled operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eElectrical Requirements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDetex currently lists the SIFV-EA as a:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12VAC–24VAC Hardwired Exit Alarm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify the existing Detex wiring, transformer, voltage, and power source before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCylinder Dogging – CD\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCD configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows authorized personnel to dog the pushpad down so the latch remains retracted during periods when free push\/pull operation is desired.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDetex specifies:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\/8-turn cylinder dogging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMortise cylinder required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard Yale-style cam required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible cylinder lengths are accommodated by the filler assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCylinder Not Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThis listing does not include the mortise cylinder.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emortise cylinder with standard Yale cam\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e must be supplied separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSlide-In Filler Design\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDetex Slide-In Filler Kits allow the function of a compatible exit device to be changed or upgraded after the original installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes the SIFV-EA-CD-48 ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit device upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlarm retrofits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepair work\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDamaged filler replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity system upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial door maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for applicable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDetex Value Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e configurations, including compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eV40 Rim Exit Devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eV50 \/ V51 Surface Vertical Rod Exit Devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e48\" Value Series Devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the exact device series and configuration before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail Emergency Exits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStockroom Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWarehouses\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial Facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGovernment Buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLoss Prevention Openings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestricted Exit Doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstitutional Facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detex\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Value Series\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SIFV-EA-CD-48\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electric Slide-In Filler Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDevice Length:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48\"\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EA Hardwired Exit Alarm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAlarm Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 100 dB\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12–24VAC Hardwired\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDogging:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Cylinder Dogging (CD)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCylinder Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/8 Turn\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePushpad Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRemote Signal:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRemote Bypass:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCylinder Required:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCylinder Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRequired Cylinder Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mortise Cylinder with Standard Yale Cam\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible Detex Value Series Exit Devices\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMortise cylinder is not included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCylinder dogging is intended for appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epanic-hardware applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Fire-rated exit devices require the proper fire-rated configuration and generally use \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLess Dogging (LD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than mechanical cylinder dogging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify the device series, length, electrical requirements, dogging configuration, cylinder, and existing hardware before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":48283683258583,"sku":"DTX-SIFV-EA-CD-48","price":638.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/DETEX_a9db042e-18ea-4394-8402-a3f3f8eb570e.png?v=1770818976","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-sifv-ea-cd-48-hardwired-exit-alarm-filler-kit","provider":"Commercial Door Worx","version":"1.0","type":"link"}