{"product_id":"detex-v40-ee-fc3-cd-delayed-egress-rim-exit-device-36-48-628","title":"Detex V40 EE FC3 CD Delayed Egress Rim Exit Device | 36\" or 48\" | 628","description":"\u003cp\u003eThe \u003cstrong\u003eDetex V40 EE FC3 CD Value Series Delayed-Egress Rim Exit Device\u003c\/strong\u003e combines controlled 15-second delayed exit operation with a built-in audible alarm and the commercial strength of a Detex V40 wide-stile rim panic device. This listing covers only the matching \u003cstrong\u003eEE \/ FC3 \/ CD \/ 99 strike \/ 628 Satin Aluminum\u003c\/strong\u003e configuration, available in a \u003cstrong\u003e36-inch or 48-inch\u003c\/strong\u003e device length.\u003c\/p\u003e\u003csection\u003e\u003ch3\u003eAdditional Product Specifications and Ordering Guidance\u003c\/h3\u003e\n\u003cp\u003eThis Detex commercial egress assembly must match the door type, factory exit-device model and approved hardware schedule. A standard mechanical panic device, an alarmed device, a delayed-egress assembly and an electrically retracting device are distinct functions even when the housings look similar.\u003c\/p\u003e\n\u003ch4\u003eExact Variant and SKU Reference\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfigured Option\u003c\/th\u003e\n\u003cth\u003eShopify SKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Length: 36 in (3 ft)\u003c\/td\u003e\n\u003ctd\u003eDTXV40-EE-FC3-CD-36-628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Length: 48 in (4 ft)\u003c\/td\u003e\n\u003ctd\u003eDTX-V40-EE-FC3-CD-48-628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBefore You Order\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure the actual door width and height and confirm rim versus vertical-rod or top-rod construction and the specified strike arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify the complete SKU for dogging, exterior trim, keyed entry, finish, factory options and any permitted field sizing.\u003c\/li\u003e\n\u003cli\u003eFor electrified functions, coordinate controller, low-voltage supply, door-to-frame transfer, reset\/bypass and required fire-alarm release interfaces.\u003c\/li\u003e\n\u003cli\u003eConfirm any fire-rated, hurricane-rated or weatherized designation against the complete opening design and current listing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelayed egress:\u003c\/strong\u003e Verify the programmed release, required signage, emergency unlock and applicable authority approval before installation; a delayed-egress part alone does not establish code compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eField Installation and Performance Checks\u003c\/h4\u003e\n\u003cp\u003eFollowing installation, test positive latch engagement, free emergency egress, proper dogging if allowed, and every applicable alarm, motorized, reset or delayed-release function.\u003c\/p\u003e\n\u003ch4\u003ePackage and Compatibility Scope\u003c\/h4\u003e\n\u003cp\u003eOne selected Detex exit-device assembly or package; outside trim, cylinders, controller, power source, special mullion and installation are not necessarily included. The complete model-specific specifications remain in the original description below.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch3\u003eCore Device Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetex V40 Value Series rim exit hardware:\u003c\/strong\u003e Commercial wide-stile mechanical panic-bar platform intended for compatible outswinging door openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEE delayed-egress control:\u003c\/strong\u003e Manufacturer-specified standard 15-second delay before release after a valid delayed-egress attempt, subject to the complete approved system and jurisdictional requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproximately 100 dB audible alarm:\u003c\/strong\u003e Alerts staff when the device is actuated in its armed delayed-egress mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC3 flexible conduit kit:\u003c\/strong\u003e Factory-specified 3-foot flex conduit provision for associated wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCD cylinder dogging configuration:\u003c\/strong\u003e This exact factory designation is retained; verify the permitted dogging function and correct cylinder\/key arrangement for the installed opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e99 surface strike:\u003c\/strong\u003e Standard specified rim-latch strike for a compatible door and frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e628 Satin Aluminum finish:\u003c\/strong\u003e Common architectural aluminum finish across both length variants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength-specific factory assemblies:\u003c\/strong\u003e Order the correct 36-inch or 48-inch model to match the opening's hardware and field-cut allowances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFactory Models and Ordering\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCommercial Door Worx SKU\u003c\/th\u003e\n\u003cth\u003eExit Device Length\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDTXV40-EE-FC3-CD-36-628\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 inches\u003c\/td\u003e\n\u003ctd\u003eV40 EE delayed egress; FC3 conduit; CD; 99 strike; 628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDTX-V40-EE-FC3-CD-48-628\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 inches\u003c\/td\u003e\n\u003ctd\u003eV40 EE delayed egress; FC3 conduit; CD; 99 strike; 628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImportant Delayed-Egress Requirements\u003c\/h3\u003e\u003cp\u003eDelayed-egress exit devices are specialized life-safety products. The 15-second operation must be allowed by the governing building and fire codes and installed with the required controls, labels, power source, release interfaces and testing. \u003cstrong\u003eNot every entrance or exit is eligible for delayed egress.\u003c\/strong\u003e Confirm the authority having jurisdiction (AHJ), occupancy classification, fire alarm integration, emergency release requirements and current Detex installation instructions before specifying the complete system.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\u003cp\u003eApproved delayed-egress openings in commercial or institutional facilities such as healthcare and assisted-living sites, museums, retail security exits, controlled warehouse passages and other buildings where the code and hardware schedule permit delayed egress.\u003c\/p\u003e\n\u003ch3\u003eSelection and Installation Checklist\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eVerify the exact \u003cstrong\u003eV40 EE FC3 CD\u003c\/strong\u003e hardware function, 99 rim strike and satin aluminum finish, and confirm compatibility with the door stile, swing and frame.\u003c\/li\u003e\n\u003cli\u003eChoose the \u003cstrong\u003e36-inch\u003c\/strong\u003e or \u003cstrong\u003e48-inch\u003c\/strong\u003e factory device and check the manufacturer's cut-down limits.\u003c\/li\u003e\n\u003cli\u003eConfirm wiring pathway and the required FC3 3-foot flex-conduit installation; verify the complete controller and power-supply specification separately.\u003c\/li\u003e\n\u003cli\u003eCheck the appropriate cylinder, keying and CD operation, including any fire-door dogging restrictions.\u003c\/li\u003e\n\u003cli\u003eIntegrate approved fire-alarm\/emergency release circuits and door-monitoring outputs if required by the installation.\u003c\/li\u003e\n\u003cli\u003eCommission delayed-release timing, alarm sound, power loss behavior, permitted authorized reset\/bypass functions and required signage.\u003c\/li\u003e\n\u003cli\u003eVerify that the installed door meets its complete egress, accessibility, and any fire-rating requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhat Is Included and Shipping\u003c\/h3\u003e\u003cp\u003eOne selected Detex \u003cstrong\u003eV40 EE FC3 CD delayed-egress rim exit device\u003c\/strong\u003e at the ordered length and identified factory configuration. Compatible power supply, system controller, keys\/cylinders, monitoring accessories and other required life-safety system elements must be verified and ordered separately where not expressly included. Both variants currently use a \u003cstrong\u003e25 lb Shopify shipping weight\u003c\/strong\u003e, retained by SKU.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"36 in (3 ft)","offer_id":47707283030231,"sku":"DTXV40-EE-FC3-CD-36-628","price":1629.08,"currency_code":"USD","in_stock":true},{"title":"48 in (4 ft)","offer_id":68003142795479,"sku":"DTX-V40-EE-FC3-CD-48-628","price":1679.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/V40-EB.png?v=1763391363","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-v40-ee-fc3-cd-delayed-egress-rim-exit-device-36-48-628","provider":"Commercial Door Worx","version":"1.0","type":"link"}