{"product_id":"detex-v40eex-w-ld-rwe-48-weatherized-delayed-egress-exit-device","title":"Detex V40EEX-W-LD-RWE-48 Delayed Egress Exit Device – Weatherized Panic Bar with Internal Blocker for Gates \u0026 Healthcare","description":"\u003cp\u003eThe \u003cstrong\u003eDetex V40EEX-W-LD-RWE-48 Delayed Egress Exit Device\u003c\/strong\u003e is a rugged, code-compliant \u003cstrong\u003epanic hardware solution\u003c\/strong\u003e engineered for \u003cstrong\u003econtrolled and delayed egress applications\u003c\/strong\u003e. Featuring the advanced \u003cstrong\u003eEEX internal blocking system with pushpad switch\u003c\/strong\u003e, this device allows seamless integration with a \u003cstrong\u003elogic controller\u003c\/strong\u003e—eliminating the need for magnetic locks while maintaining superior safety and security.\u003c\/p\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003erim and surface vertical rod (SVR) applications\u003c\/strong\u003e, this \u003cstrong\u003eweatherized exit device\u003c\/strong\u003e is ideal for both \u003cstrong\u003eoutdoor gate security\u003c\/strong\u003e and \u003cstrong\u003ehealthcare-controlled environments\u003c\/strong\u003e. Whether securing \u003cstrong\u003egarden centers, stadiums, or pool gates\u003c\/strong\u003e, or managing \u003cstrong\u003epatient safety in psychiatric, memory care, and NICU settings\u003c\/strong\u003e, this device delivers reliable performance where it matters most.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEEX Internal Blocking System:\u003c\/strong\u003e Built-in blocker and pushpad switch enable delayed or controlled egress\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Magnetic Lock Required:\u003c\/strong\u003e Panic hardware provides secure delayed exit without maglocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Controller Integration:\u003c\/strong\u003e Controls power to the internal blocker for precise operation \u003cem\u003e(required, sold separately)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeatherized (RWE):\u003c\/strong\u003e Ideal for exterior gates and harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePushpad Activation:\u003c\/strong\u003e Triggers nuisance alarm (delayed egress) or full alarm (controlled egress) while maintaining security\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Safety:\u003c\/strong\u003e Allows immediate egress during power failure or fire alarm conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Most Doors:\u003c\/strong\u003e Versatile design complements nearly any door and décor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built for long-term, trouble-free use in high-traffic areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Pre-engineered design reduces install time, errors, and maintenance costs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure System Design:\u003c\/strong\u003e Enhances reliability and minimizes service issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eSystem Requirements \u0026amp; Notes:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Controller Required (Sold Separately)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eExample: \u003cem\u003eDetex 106595-1 Power Supply\/Logic Controller (NEMA 4X enclosure)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFactory-programmed, pre-wired controller options available\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Alarm Override Required\u003c\/strong\u003e (connected at power supply\/logic controller)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRemote bypass and signaling supported via controller\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode-Compliant Signage Available:\u003c\/strong\u003e ECL-395, 101906\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGarden center gates \u0026amp; outdoor retail\u003c\/li\u003e\n\u003cli\u003eAmusement parks \u0026amp; sports arenas\u003c\/li\u003e\n\u003cli\u003eSwimming pool enclosures\u003c\/li\u003e\n\u003cli\u003ePerimeter fencing \u0026amp; courtyards\u003c\/li\u003e\n\u003cli\u003ePsychiatric \u0026amp; behavioral health facilities\u003c\/li\u003e\n\u003cli\u003eMemory care \u0026amp; dementia units\u003c\/li\u003e\n\u003cli\u003eHospitals, NICUs, and birthing centers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eWhy Choose Detex EEX Exit Devices?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eDetex EEX technology provides a \u003cstrong\u003esafer alternative to maglocks\u003c\/strong\u003e, combining \u003cstrong\u003elife safety, code compliance, and security\u003c\/strong\u003e in one durable exit device. With built-in intelligence and seamless controller integration, it’s the ideal solution for \u003cstrong\u003ehigh-risk and regulated environments\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Default Title","offer_id":48545822539991,"sku":"DTXV40EEX-W-LD-RWE-48","price":1435.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/4933\/1927\/files\/DETEXEEX.png?v=1777400401","url":"https:\/\/shop.commercialdoorworx.com\/products\/detex-v40eex-w-ld-rwe-48-weatherized-delayed-egress-exit-device","provider":"Commercial Door Worx","version":"1.0","type":"link"}