Securitron M62 MagnaLock – 1,200 lb Holding Force – 12/24VDC – Satin Stainless Steel
Securitron M62 MagnaLock – 1,200 lb Holding Force – 12/24VDC – Satin Stainless Steel
Securitron M62 MagnaLock – 1,200 lb Holding Force – 12/24VDC – Satin Stainless Steel
$659.00
$593.10
/
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Secure high-traffic commercial openings with the Securitron M62 MagnaLock, a heavy-duty electromagnetic lock delivering up to 1,200 lb of holding force.
Designed for interior, perimeter, and exterior access-control applications, the M62 features automatic dual-voltage 12/24VDC operation, fully sealed electronics, instant release with no residual magnetism, and a durable US32D / 630 Satin Stainless Steel finish.
Its high holding force and weather-resistant construction make it an excellent choice for commercial doors requiring reliable electromagnetic locking.
Key Features
-
Genuine Securitron / ASSA ABLOY
-
Model: M62
-
1,200 lb holding force
-
Automatic 12/24VDC dual-voltage
-
No field voltage adjustment required
-
Current draw:
-
250 mA @ 12VDC
-
150 mA @ 24VDC
-
-
Fully sealed electronics
-
Suitable for indoor or outdoor use
-
Instant-release circuit
-
No residual magnetism
-
Built-in MOV noise suppression
-
Rust-resistant plated ferrous components
-
10 ft jacketed conductor cable
-
Direct-mount configuration
-
US32D / 630 Satin Stainless Steel
-
3-hour fire-rated platform
-
UL 10C Listed
-
ANSI/UL 294 Listed
-
ANSI/BHMA A156.23 Grade 2
-
MagnaCare® lifetime replacement warranty
1,200 lb Holding Force
The M62 provides:
Holding Force: 1,200 lb / 544 kg
This makes it suitable for higher-security commercial openings where greater resistance to forced entry is required.
Typical applications include:
-
Exterior entrances
-
Controlled-access doors
-
Government facilities
-
Schools
-
Hospitals
-
Warehouses
-
Offices
-
Industrial buildings
-
Secure interior openings
Automatic 12/24VDC Operation
The M62 automatically accepts either:
12VDC
or
24VDC
No internal jumper or field voltage adjustment is required.
Electrical Requirements
12VDC: 250 mA
24VDC: 150 mA
Use a properly sized, filtered and regulated power supply appropriate for the complete access-control system.
Instant Release – No Residual Magnetism
Securitron incorporates an instant-release circuit designed to eliminate residual magnetism when power is removed.
This helps ensure that the door releases immediately when the MagnaLock is de-energized.
Fail-Safe Operation
Like standard electromagnetic locks, the M62 is:
Fail Safe
When power is applied, the magnetic lock secures the door.
When power is removed, the lock releases.
Because fail-safe maglocks affect means of egress, the complete installation must include all release controls required by applicable building, fire, accessibility, and life-safety codes.
Fully Sealed Electronics
The M62 features fully sealed electronics for demanding installations.
Securitron publishes the M62 for:
Indoor or Outdoor Use
with an operating temperature range of approximately:
-40°F to +140°F
-40°C to +60°C
This allows the M62 to be used in many exterior and perimeter access-control applications.
Satin Stainless Steel Finish
US Finish: US32D
BHMA Finish: 630
Description: Brushed / Satin Stainless Steel
The architectural stainless finish provides a clean commercial appearance and coordinates with common stainless door hardware.
Lock Dimensions
MagnaLock:
-
Length: 8"
-
Height: 3"
-
Depth: 1-3/4"
Standard Strike Plate:
-
Length: 6"
-
Height: 2-3/4"
-
Thickness: 1/2"
Direct-Mount Design
The standard M62 uses a direct-mount configuration.
Securitron uses heavy-duty blind mounting nuts to secure the lock to compatible door frames.
Optional mounting and strike configurations are available for specialized installations.
Available M62 Options
Securitron offers additional M62 configurations including:
-
B – BondSTAT magnetic bond sensor
-
D – Door Position Switch
-
BD – BondSTAT + Door Position Switch
-
F – Face Drilled
-
G – Gate Conduit
-
OS – Offset Strike
-
SS – Split Strike
-
SASM – Shock Absorbing Strike Mount
This listing is for the standard M62 unless one of these options is specifically selected.
Fire & Access-Control Listings
Current Securitron documentation lists the M62 as:
-
UL 10C Listed
-
ANSI/UL 294 Listed
-
CAN4-S104 / CAN-ULC-S533 Listed
-
CSA C22.2 No. 205 Listed
-
ANSI/BHMA A156.23 Grade 2
-
California State Fire Marshal approved
The M62 platform is also published as 3-hour fire rated when used in an appropriate listed opening.
MagnaCare® Warranty
The M62 is covered by Securitron’s MagnaCare® Lifetime Replacement Warranty.
Securitron describes MagnaCare as a no-fault, no-questions-asked lifetime replacement program for covered electromagnetic locking products.
Common Applications
Ideal for:
-
Access-controlled entrances
-
Exterior commercial doors
-
Interior secure doors
-
Office buildings
-
Hospitals
-
Healthcare facilities
-
Schools and universities
-
Government facilities
-
Warehouses
-
Industrial facilities
-
Perimeter security
-
High-security commercial openings
Product Specifications
Brand: Securitron
Manufacturer: ASSA ABLOY
Model: M62
Product Type: Electromagnetic Lock / MagnaLock
Holding Force: 1,200 lb
Input Voltage: Automatic 12/24VDC
Current Draw @ 12VDC: 250 mA
Current Draw @ 24VDC: 150 mA
Operation: Fail Safe
Mounting: Direct Mount
Lock Dimensions: 8" L x 3" H x 1-3/4" D
Strike Dimensions: 6" L x 2-3/4" H x 1/2" D
Finish: US32D / 630
Finish Description: Satin Stainless Steel
Environment: Indoor / Outdoor
Operating Temperature: -40°F to +140°F
Fire Rating: Up to 3 Hours Where Applicable
Grade: ANSI/BHMA A156.23 Grade 2
UL Listing: UL 10C / UL 294
Warranty: MagnaCare Lifetime Replacement
What's Included
-
Securitron M62 MagnaLock
-
Standard armature / strike plate
-
10 ft jacketed conductor cable
-
Standard mounting components supplied with the lock
Not Included Unless Specifically Stated
-
Power supply
-
Access-control panel
-
Card reader
-
Keypad
-
Request-to-exit device
-
Emergency release device
-
Door position switch
-
BondSTAT monitor
-
Specialized mounting brackets
-
Door or frame
Important Ordering Information
Before ordering, verify:
-
Required 1,200 lb holding force
-
12VDC or 24VDC system
-
Door and frame construction
-
Direct-mount suitability
-
Interior versus exterior installation
-
Required monitoring options
-
Required strike style
-
Fire-alarm release requirements
-
Request-to-exit requirements
-
Applicable local egress codes
Electromagnetic locks must be installed as part of a compliant access-control and egress system.