2 Amp 24VDC Power Supply Box | Commercial Access Control
2 Amp 24VDC Power Supply Box | Commercial Access Control
2 Amp 24VDC Power Supply Box | Commercial Access Control
$432.44
/
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
24VDC Access Control Power Supply | 2 Amp Output | Enclosed Commercial Power Supply
Provide dependable low-voltage power for compatible electrified door hardware with this 2 Amp 24VDC Power Supply Box, designed for commercial access-control and security applications.
Delivering 24VDC output with up to 2 amps of available current, this enclosed power supply is ideal for powering compatible electric strikes, magnetic locks, electrified locks, access-control components, and other 24VDC door hardware.
The protective enclosure keeps the power supply components organized and protected, making it well suited for commercial, institutional, and security-system installations.
Key Features
-
Commercial access-control power supply
-
24VDC output
-
2 Amp output capacity
-
Enclosed power-supply design
-
Designed for compatible low-voltage door hardware
-
Helps provide centralized power for access-control systems
-
Suitable for electric locks and strikes
-
Ideal for commercial and institutional installations
-
Clean, protected enclosure
-
Suitable for new installations, replacements, and system upgrades
24VDC Output
This power supply provides:
Output Voltage: 24VDC
24VDC is commonly used with a wide range of commercial electrified door and access-control components.
Always verify the voltage requirement of the connected device before installation.
2 Amp Capacity
Maximum available output:
2 Amps
The total current draw of all connected devices must remain within the rated capacity of the power supply.
For example, when multiple devices are connected, add their individual current requirements together before determining whether the 2A supply is suitable.
Common Access-Control Applications
Suitable for compatible:
-
Electric strikes
-
Magnetic locks
-
Electrified mortise locks
-
Electrified cylindrical locks
-
Electric exit-device trim
-
Request-to-exit devices
-
Access-control relays
-
Door controllers
-
Keypads
-
Card-reader systems
-
Other compatible 24VDC equipment
Centralized Power for Electrified Doors
Using a dedicated power supply allows compatible door hardware to receive properly regulated low-voltage power from a centralized enclosure.
This can simplify:
-
Wiring
-
Service
-
Troubleshooting
-
Power distribution
-
Access-control upgrades
-
Replacement of failed power supplies
Enclosed Design
The power-supply components are housed inside a protective box for a clean commercial installation.
An enclosure helps protect wiring and electrical components while providing an organized location for system connections.
Mounting location should allow adequate access for:
-
Service
-
Wiring
-
Troubleshooting
-
Inspection
Product Specifications
Product Type: Access Control Power Supply
Output Voltage: 24VDC
Output Capacity: 2 Amps
Configuration: Enclosed Power Supply Box
Application: Commercial Access Control
Use: Electrified Door Hardware / Security Systems
Installation: New / Replacement / Retrofit
Common Applications
Ideal for:
-
Commercial buildings
-
Retail stores
-
Office buildings
-
Schools
-
Universities
-
Hospitals
-
Healthcare facilities
-
Warehouses
-
Government buildings
-
Industrial facilities
-
Apartment common areas
-
Secure employee entrances
-
Institutional facilities
Current Load Calculation
Before connecting multiple devices, determine the total current draw.
Example:
Electric Strike: 0.40A
Maglock: 0.50A
Access-Control Device: 0.10A
Total Load: 1.00A
A 2A power supply provides sufficient rated capacity for this example, assuming all devices are compatible with 24VDC and the manufacturer's installation requirements are followed.
Additional design margin may be appropriate depending on the system.
Important Compatibility Note
Before ordering, verify:
-
Required output voltage
-
Total current draw
-
Number of connected devices
-
Lock operating mode
-
Access-control wiring requirements
-
Required relay functions
-
Battery-backup requirements
-
Fire-alarm interface requirements
-
Local electrical and life-safety requirements
Do not connect equipment requiring a different voltage unless specifically approved for 24VDC operation.
Battery Backup
Some access-control power supplies support standby batteries, while others do not.
Do not assume batteries, charging circuitry, or battery-backup capability are included unless specifically stated for the selected model.
If battery backup is required, verify:
-
Battery compatibility
-
Charging capability
-
Required amp-hour capacity
-
Required standby time
-
Available enclosure space
Fire Alarm & Life Safety
Access-controlled openings may require integration with:
-
Fire alarm systems
-
Emergency release circuits
-
Egress hardware
-
Life-safety controls
System design must comply with the requirements of the complete opening and applicable codes.
The power supply alone does not determine whether an opening is code compliant.
Installation Notes
Installation should include proper consideration of:
-
AC input requirements
-
Low-voltage wiring
-
Wire gauge
-
Voltage drop
-
Current load
-
Grounding
-
Short-circuit protection
-
Device polarity
-
Enclosure mounting
-
Access-control sequencing
Follow the instructions supplied with the actual power supply and connected hardware.