Detex ECL-600 — Heavy-Duty Fire Rated Exit Control Lock with Integrated Alarm
Detex ECL-600 — Heavy-Duty Fire Rated Exit Control Lock with Integrated Alarm
Detex ECL-600 — Heavy-Duty Fire Rated Exit Control Lock with Integrated Alarm
$956.21
/
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
3-Hour Fire Exit Hardware | 36"–48" Door Width | 100 dB Alarm | Relatching Deadbolt & Latchbolt
Protect secondary fire exits with the Detex ECL-600 Fire-Rated Exit Control Lock, a rugged commercial security device combining fire exit hardware, automatic relatching, high-security locking, and an integrated 100 dB alarm.
Designed for demanding retail, commercial, institutional, and industrial applications, the ECL-600 uses a 1" throw deadbolt and 3/4" deadlocking latchbolt to provide secure positive latching while maintaining the operation required of a properly configured fire exit opening.
The long operating bar is designed for 36" to 48" wide doors, and the factory photoluminescent plate clearly identifies the opening as an emergency exit.
Key Features
-
Genuine Detex ECL-600
-
Heavy-duty fire-rated exit control lock
-
Warnock Hersey / Intertek listed fire exit hardware
-
UL 10B listed
-
Up to 3-hour fire rating when installed in an approved assembly
-
For 36"–48" wide doors
-
1" throw deadbolt
-
3/4" deadlocking latchbolt
-
Automatic relatching
-
Saw-resistant deadbolt
-
Built-in 100 dB alarm
-
Includes 9V battery
-
Photoluminescent metal exit plate
-
Long operating bar
-
Non-handed
-
Corrosion-resistant alloy lock body
-
Accepts compatible rim cylinders
-
Alarm can only be reset with the control key
-
Available in Gray or Black
-
Keeper and strike kit included
-
Designed for high-abuse secondary fire exits
Fire-Rated Exit Control Hardware
The ECL-600 is specifically designed for openings that require both fire-door positive latching and controlled secondary-exit security.
Detex lists the ECL-600 for:
Single Metal Door:
Up to 4'0" x 8'0"
Up to 3 Hours
Pair of Doors:
Up to 8'0" x 8'0"
Up to 3 Hours when used with the appropriate listed Detex fire-rated mullion configuration.
The actual rating of the opening depends on the listing and proper installation of the complete door, frame, hardware, and associated components.
Automatic Relatching
One of the major differences between the ECL-600 and a conventional alarmed deadbolt is its relatching design.
The device incorporates:
-
1" deadbolt
-
3/4" deadlocking latchbolt
The latchbolt automatically engages when the door closes, helping maintain the positive-latching function required at compatible fire-door openings.
1" Saw-Resistant Deadbolt
The ECL-600 incorporates a:
1" Throw Saw-Resistant Deadbolt
This provides additional security against forced entry at secondary exits.
Detex states that the device's attack-resistant design withstands more than 2,200 lb of outside pull force.
3/4" Deadlocking Latchbolt
In addition to the deadbolt, the ECL-600 uses a:
3/4" Deadlocking Latchbolt
This additional latching point allows the opening to relatch automatically after the door closes, an important distinction for fire-rated openings.
Integrated 100 dB Alarm
The ECL-600 incorporates a loud:
100 dB Audible Alarm
The alarm helps alert facility personnel when the protected secondary exit is operated.
Common uses include:
-
Loss prevention
-
Unauthorized-exit deterrence
-
Emergency-exit monitoring
-
Restricted secondary exits
-
Employee-only exit doors
Key Reset
Once the ECL-600 alarm has been activated:
The alarm can only be reset using the control key.
This prevents an unauthorized user from simply silencing the alarm after opening the door.
Key Operation Arms & Disarms the Alarm
Detex states that locking and unlocking the deadbolt automatically arms and disarms the alarm.
This integrates normal mechanical locking operation with the alarm system and simplifies daily use.
Photoluminescent Emergency Exit Plate
The ECL-600 includes a durable metal photoluminescent English paddle-bar plate.
The standard factory plate is:
Detex ECL-2109
It provides high-visibility emergency-exit identification and remains more visible under reduced-light conditions.
Long Bar for 36"–48" Doors
The ECL-600 is supplied with the long operating bar designed for:
36" to 48" Door Widths
This makes one model suitable for many standard:
-
3'0" doors
-
3'6" doors
-
4'0" doors
Verify the actual door width and installation dimensions before ordering.
Rim Cylinder Operation
The ECL-600 accepts compatible rim cylinders.
Detex specifies compatibility with:
-
5-pin standard rim cylinders
-
6-pin configurations
-
7-pin configurations
-
Compatible interchangeable-core rim cylinders
A cylinder collar may be required for certain 6- or 7-pin cylinder configurations.
Important
The ECL-600 is factory supplied:
Less Control Cylinder
A compatible rim cylinder must be ordered separately.
Non-Handed Design
The ECL-600 is non-handed, allowing it to be used on compatible left- or right-hand openings without ordering separate handed lock bodies.
Door swing and complete installation requirements must still be verified before installation.
Available Finishes
Detex currently offers the ECL-600 in:
-
Gray
-
Black
Product Specifications
Manufacturer: Detex
Model: ECL-600
Product Type: Fire-Rated Exit Control Lock
Door Width: 36"–48"
Fire Listing: Warnock Hersey / Intertek
Fire Test Listing: UL 10B
Maximum Listed Rating: Up to 3 Hours
Maximum Single Door: 4'0" x 8'0"
Maximum Listed Pair: 8'0" x 8'0" with compatible listed mullion
Deadbolt: 1" Throw
Latchbolt: 3/4" Deadlocking
Alarm: 100 dB
Power: 9V Battery
Battery Included: Yes
Operation: Relatching
Handing: Non-Handed
Cylinder: Rim Cylinder Required – Sold Separately
Plate: ECL-2109 English Photoluminescent Long Plate
Finishes: Gray or Black
Application: Secondary Fire Exit / Commercial Security
Supplied With
The current factory configuration includes:
-
ECL-600 exit control lock
-
Long operating bar
-
9V battery
-
Cover lock
-
2 cover-lock keys
-
Keeper and strike kit
-
ECL-2109 English photoluminescent paddle-bar plate
Optional Accessories
Compatible ECL-600 accessories include:
-
ECL-620 Outside Lever Trim
-
ECL-445K Rim Cylinder
-
ECL-1595 Cylinder Collar for applicable 6- or 7-pin cylinders
-
BE-961 Hardwired Conversion Kit
-
F90KR Keyed Removable Fire-Rated Mullion
-
ECL-435K Adjustable Surface Keeper Bracket
-
ECL-2100K Bar Guard Kit where required by the application
ECL-620 Outside Lever Trim
For openings requiring exterior lever access, the compatible:
Detex ECL-620 Outside Lever Trim
is available separately.
The lever retracts the latchbolt only, while the rim cylinder operates the deadbolt.
Battery or Hardwired Operation
The standard ECL-600 is powered by a:
9V Battery – Included
For applications where battery operation is not preferred, Detex offers the BE-961 hardwired conversion kit as an optional accessory.
Common Applications
Ideal for:
-
Retail back doors
-
Fire-rated secondary exits
-
Warehouses
-
Distribution centers
-
Schools
-
Universities
-
Hospitals
-
Healthcare facilities
-
Government buildings
-
Manufacturing facilities
-
Industrial buildings
-
Stockrooms
-
Commercial facilities
-
Loss-prevention exits
-
Restricted emergency exits
Fire Door Compliance Note
A Detex ECL-600 by itself does not make an opening fire rated.
The complete opening must use properly listed and compatible:
-
Door
-
Frame
-
ECL-600
-
Keeper / strike
-
Hinges or pivots
-
Door closer
-
Mullion where applicable
-
Seals and gasketing where required
-
Other required fire-door hardware
The door must properly close and positively latch after use.
The ECL-600's published three-hour rating applies only when it is installed as part of the appropriate tested and listed fire-door assembly.
Important Ordering Information
Before ordering, verify:
-
Door width is between 36" and 48"
-
Door height
-
Door and frame construction
-
Required fire rating
-
Single or paired-door application
-
Required Gray or Black finish
-
Rim-cylinder keyway
-
Cylinder type and length
-
Outside lever-trim requirements
-
Mullion requirements on pairs
-
Applicable local fire and life-safety requirements
What's Included
(1) Detex ECL-600 Fire-Rated Exit Control Lock