Power and control compatible electrified exit devices with the ACSI 1406-04-AO Series 1400 Power Supply.
Designed specifically for ACSI Series 1550 electric solenoid latch-retraction exit devices, the 1406-04-AO provides the power, timing, sequencing, automatic-door-operator interface, and fire-alarm interface needed for sophisticated commercial access-control openings.
The system can control one or two exit devices independently, or sequence a pair of exit devices from a single activation input.
Key Features
-
Genuine ACSI – Architectural Control Systems
-
Model 1406-04-AO
-
ACSI Series 1400
-
Designed for ACSI Series 1550 Electric Solenoid Latch Retraction
-
Controls up to two electrified exit devices
-
Independent control of two single doors
-
Sequential control of a pair of doors
-
Automatic door operator interface
-
Two independent automatic-operator outputs
-
Fire alarm interface
-
Field-adjustable latch-retraction time delay
-
Auxiliary 24VDC output
-
Auxiliary 12VDC output
-
Class 2 rated outputs
-
Overload protection
-
Over-voltage protection
-
Short-circuit protection
-
UL Listed
-
Tested to UL 294
-
NEMA Type 1 enclosure
-
Designed for commercial access-control systems
-
Ideal for ACSI electrified panic and fire-exit hardware applications
Series 1550 Latch Retraction Power Supply
The 1406-04-AO is designed to operate exit devices equipped with compatible:
ACSI Series 1550 Electric Solenoid Latch Retraction
These high-current latch-retraction devices require a purpose-built power supply capable of providing the initial power needed to retract the exit-device latch and maintain proper operation.
Important
The 1406 is specifically identified by ACSI for its 1550 electric solenoid latch-retraction system.
Always verify compatibility when using newer ACSI motor-drive or other electrified exit-device configurations.
Controls Up to Two Exit Devices
The 1406 can provide power and control for:
Up to Two ACSI 1550 Electrified Exit Devices
The system can be configured for two different operating arrangements.
Independent Door Control
Two individual exit devices can be controlled through:
Separate Inputs
This is useful for two separate access-controlled doors that need independent operation.
Sequential Pair Operation
Two exit devices can also operate:
Sequentially from a Single Input
This is useful for paired-door applications where both devices must retract in a controlled sequence.
Automatic Door Operator Interface
The AO configuration incorporates interface capability for automatic door operators.
The 1406-04-AO provides:
Two Independent Automatic Door Operator Outputs
This makes it well suited for openings combining:
-
Electrified panic hardware
-
Access control
-
Automatic swing operators
-
ADA activation switches
-
Card readers
-
Keypads
Typical Automatic Door Sequence
A properly configured system can operate as follows:
-
Access credential is accepted
-
1406 receives an activation signal
-
Exit-device latch retracts
-
Adjustable time delay allows latch retraction to complete
-
Automatic door operator is activated
-
Door opens
-
Door completes its operating cycle
-
Hardware returns to secure operation
Proper sequencing helps prevent the automatic operator from attempting to open the door before the exit-device latch is fully retracted.
Field-Adjustable Latch Retraction Time Delay
The 1406 includes:
Field-Adjustable Latch Retraction Time Delay
This allows installers to coordinate the timing between:
-
Exit-device latch retraction
-
Automatic operator activation
-
Door movement
Correct timing is particularly important on automatic openings.
Fire Alarm Interface
The 1406 includes an input for connection to a:
Fire Alarm System
This allows the electrified opening to be integrated with applicable life-safety system requirements.
Actual fire-alarm behavior depends on the complete hardware and control configuration.
Always follow:
-
Exit-device listing requirements
-
Fire-door requirements
-
Building codes
-
Life-safety codes
-
Authority Having Jurisdiction requirements
Auxiliary Power Outputs
The non-battery-backup 1406 provides auxiliary constant-voltage outputs for powering compatible low-current devices.
24VDC Auxiliary Output
24VDC – 250mA
12VDC Auxiliary Output
12VDC – 250mA
These outputs may be used for compatible accessories such as:
-
Keypads
-
Motion detectors
-
Status indicators
-
Access-control accessories
-
Relays
Always verify the total accessory current before connection.
1550 Device Outputs
ACSI's current Series 1400 technical specifications list the 1406 latch-retraction outputs as:
40VDC – 1.5A Combined
Filtered / Unregulated
These outputs are specifically designed around compatible ACSI Series 1550 solenoid latch-retraction hardware.
Input Power
120VAC
0.75A
60Hz
The unit must be installed according to applicable electrical codes and ACSI installation instructions.
Class 2 Rated Outputs
The 1406 incorporates:
Class 2 Rated Outputs
for applicable low-voltage circuits.
Electrical Protection
Built-in protection includes:
-
Overload protection
-
Over-voltage protection
-
Short-circuit protection
These protections help safeguard the power supply and connected equipment against abnormal electrical conditions.
UL 294
The Series 1400 power supply is:
UL Listed and Tested to UL 294
for access-control system applications.
Enclosure
The 1406 is housed in a:
NEMA Type 1 Screw-Cover Junction Box
Enclosure Dimensions
Approximately:
10" x 10" x 4"
The enclosure is designed for indoor commercial electrical installations.
Approximate Weight
12 lbs.
Common Applications
Ideal for:
-
Electrified panic hardware
-
Electric latch-retraction exit devices
-
Automatic swing-door systems
-
Access-controlled entrances
-
ADA automatic-door openings
-
Schools
-
Universities
-
Hospitals
-
Healthcare facilities
-
Government buildings
-
Airports
-
Office buildings
-
Retail facilities
-
Institutional facilities
-
Paired-door openings
-
High-traffic commercial entrances
Compatible Hardware
Designed primarily for:
ACSI Series 1550 Electric Solenoid Latch Retraction Exit Devices
Additional system components may include:
-
ACSI Series 1100 electric hinges
-
Electrified power transfers
-
Access-control panels
-
Card readers
-
Keypads
-
Automatic door operators
-
Fire-alarm systems
-
Remote switches
Product Specifications
Brand: ACSI
Manufacturer: Architectural Control Systems, Inc.
Series: 1400
Model: 1406-04-AO
Product Type: Electric Latch Retraction Power Supply / Controller
Primary Application: ACSI Series 1550 Solenoid Latch Retraction
Number of Exit Devices: Up to 2
Door Control: Independent or Sequential
Input Voltage: 120VAC
Input Current: 0.75A
Input Frequency: 60Hz
1550 Device Output: 40VDC / 1.5A Combined
Device Output Type: Filtered / Unregulated
Auxiliary 24V Output: 24VDC / 250mA
Auxiliary 12V Output: 12VDC / 250mA
Automatic Operator Interface: Yes
Automatic Operator Outputs: 2 Independent
Fire Alarm Interface: Yes
Latch Retraction Delay: Field Adjustable
Class 2 Outputs: Yes
Overload Protection: Yes
Over-Voltage Protection: Yes
Short-Circuit Protection: Yes
UL 294: Yes
Enclosure: NEMA Type 1 Screw Cover
Enclosure Size: Approx. 10" x 10" x 4"
Approximate Weight: 12 lbs.
Battery Backup: No
What's Included
Standard 1406-04-AO package includes:
-
ACSI 1406 power-supply/controller assembly
-
Transformer
-
Control electronics
-
NEMA Type 1 enclosure
-
Automatic-operator interface circuitry
-
Fire-alarm interface
-
Installation documentation
Not Included
-
ACSI Series 1550 exit device
-
Electric hinge or power transfer
-
Automatic door operator
-
Card reader
-
Keypad
-
Access-control panel
-
Fire-alarm panel
-
Field wiring
-
Batteries
-
Door
-
Frame
-
Installation labor
Important Ordering Information
Before ordering, verify:
-
Exact electrified exit-device model
-
Solenoid latch-retraction compatibility
-
Number of exit devices
-
Independent or paired-door operation
-
Automatic-door-operator requirements
-
Fire-alarm interface requirements
-
Auxiliary-device current load
-
Wire size and distance
-
Required battery backup
Battery Backup
The standard 1406-04-AO does not include battery backup.
For battery-backup applications, use the appropriate:
ACSI 1406BB
configuration.
Day / Night Control
For applications requiring a separate day/night input, use the:
ACSI 1426
Series power supply.