Add electrically controlled access and integrated door-position monitoring to a commercial mortise-lock opening with the ACSI ACL9080EU/EL-DPS Electrified Mortise Lock Body.
Based on the Schlage L9080 mortise-lock platform, this configuration combines field-selectable Fail Safe / Fail Secure electrification with ACSI's integrated DPS Door Position Sensor.
The DPS system monitors whether the door is open or closed through a magnetic sensor incorporated into the mortise lock and a corresponding magnet positioned behind the ASA strike.
This configuration is ideal for commercial access-control systems that need both electrical control of the outside lever and reliable door-position status without adding a separate surface-mounted door contact.
Key Features
-
Genuine ACSI – Architectural Control Systems
-
Model ACL9080EU/EL-DPS
-
Based on the Schlage L9080 mortise-lock platform
-
Electrified commercial mortise lock body
-
Field-selectable:
-
EU – Fail Secure / Power Unlock
-
EL – Fail Safe / Power Lock
-
-
DPS – Door Position Sensor included
-
Monitors door open / closed status
-
Magnetic sensor integrated into mortise lock
-
Strike-mounted magnet activates DPS sensor
-
12VAC
-
12VDC
-
24VAC
-
24VDC
-
Continuous-duty rated
-
Electrically controlled outside trim
-
Mechanical inside egress
-
Key override capability with compatible cylinder
-
Suitable for access-control systems
-
Interfaces with compatible life-safety systems
-
Commercial Grade 1 mortise-lock platform
-
Lock body only – trim and cylinder sold separately
DPS – Door Position Sensor
The DPS suffix adds integrated:
Door Position Monitoring
ACSI's DPS system uses a magnetic sensor inside the mortise-lock assembly.
A magnet positioned behind the compatible ASA strike interacts with the lock-mounted sensor when the door reaches the closed position.
This allows the connected access-control system to determine whether the door is:
-
Closed
-
Open
-
Held open
-
Not fully returned to the secure position
Integrated Door Monitoring
Because the sensor is integrated into the mortise-lock assembly, the DPS option can eliminate the need for a separate exposed surface-mounted magnetic contact in many applications.
This provides a cleaner installation while still allowing the access-control system to monitor door status.
Typical DPS Operation
A properly configured system may operate as follows:
-
Door is closed
-
Lock-mounted magnetic sensor detects the strike magnet
-
DPS indicates the door is in the closed position
-
User opens the door
-
Sensor moves away from the strike magnet
-
DPS changes state
-
Access-control system recognizes the door as open
-
Door closes and DPS returns to the closed-door state
The access-control panel determines how the DPS signal is interpreted and reported.
Door Held Open Monitoring
When used with a compatible access-control system, the DPS signal can help create:
Door Held Open Alerts
For example, if the door remains open longer than the programmed allowable time, the system can generate an alarm or notification.
This is useful for:
-
Secure offices
-
Server rooms
-
Hospitals
-
Schools
-
Government facilities
-
Controlled storage areas
Door Forced Open Applications
DPS can also be used as part of a:
Door Forced Open Monitoring System
If the door changes from closed to open without the expected authorization event, the access-control panel can be programmed to treat the event as an alarm.
The exact behavior depends on the connected access-control system and other installed monitoring equipment.
Field-Selectable Fail Safe / Fail Secure
The ACL9080EU/EL-DPS allows the electrical operating mode to be selected for the opening.
EU – Fail Secure / Power Unlock
Power Applied = Outside Lever Unlocked
Power Removed = Outside Lever Locked
If electrical power is lost, the outside side remains secured.
This configuration is commonly selected where security must be maintained during a power failure.
EL – Fail Safe / Power Lock
Power Applied = Outside Lever Locked
Power Removed = Outside Lever Unlocked
If electrical power is lost, the outside side becomes unlocked.
This configuration may be required for certain life-safety or emergency-release applications.
Important
Fail-safe versus fail-secure operation should be selected according to:
-
Building code requirements
-
Fire code requirements
-
Security requirements
-
Egress requirements
-
Access-control sequence
-
Life-safety requirements
-
Authority Having Jurisdiction requirements
L9080-Style Electrified Storeroom Function
The ACL9080EU/EL-DPS is based on the commercial L9080 storeroom-type function.
Typical operation includes:
Outside Lever
Electrically controlled according to the selected EU or EL mode.
Inside Lever
Provides mechanical egress.
Key Cylinder
A compatible mortise cylinder can provide mechanical outside access.
Door Position
Monitored through the integrated DPS sensor.
Mechanical Key Override
When fitted with a compatible mortise cylinder, the latchbolt can be mechanically retracted with a key when required.
This provides authorized mechanical access even when the outside lever is electrically secured.
Electrical operation resumes according to the access-control system after key operation.
12 / 24 VAC or DC Operation
The ACL9080EU/EL-DPS can operate from:
-
12VAC
-
12VDC
-
24VAC
-
24VDC
This provides flexibility for integration into new or existing commercial access-control systems.
Before installation, verify:
-
Available voltage
-
Power-supply capacity
-
Wire gauge
-
Wire distance
-
Control relay rating
-
Power-transfer requirements
Continuous-Duty Operation
ACSI's Series 1500 electrified mortise-lock platform is designed for:
Continuous-Duty Operation
This allows the electrification to remain energized for extended periods when properly powered.
Typical applications include:
-
Scheduled access periods
-
Business-hours locking
-
Business-hours unlocking
-
Controlled office entrances
-
Secure rooms
-
Institutional access control
Access-Control Integration
The ACL9080EU/EL-DPS can be integrated with compatible:
-
Card readers
-
Keypads
-
Mobile credential readers
-
Access-control panels
-
Time schedules
-
Remote switches
-
Control relays
-
Building management systems
-
Security management systems
The DPS signal connects to an appropriate monitoring input on the access-control system.
DPS vs RX
The ACL9080EU/EL-DPS does not include RX Request-to-Exit monitoring unless separately specified.
DPS
Monitors:
Door Position
RX
Monitors:
Operation of the Inside Trim / Authorized Egress
If both functions are required, use the appropriate:
ACL9080EU/EL-RXDPS
configuration.
DPS vs LM
The DPS option should also not be confused with:
LM – Latch Bolt Monitor
DPS
Monitors whether the:
Door is open or closed
LM
Monitors whether the:
Main latchbolt is fully extended
These are separate monitoring functions.
Life-Safety Integration
ACSI electrified mortise locks can be incorporated into compatible:
-
Fire alarm systems
-
Emergency-release circuits
-
Stairwell control systems
-
Access-control systems
-
Building security systems
Final system behavior depends on the selected fail mode and the requirements of the complete opening.
Mortise Lock Construction
Lock Type: Commercial Mortise Lock
Platform: Schlage L9080
Typical Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Function: Electrified Storeroom / Controlled Entry
Inside Egress: Mechanical
Outside Access: Electrically Controlled
Door Position Monitoring: Integrated DPS
Fire-Rated Applications
Compatible electrified mortise-lock configurations can be used as part of properly listed fire-door assemblies.
For fire-rated applications, verify the complete:
-
Door
-
Frame
-
Mortise lock
-
Lever trim
-
Cylinder
-
Strike
-
DPS installation
-
Electrification
-
Power supply
-
Wiring
-
Access-control system
The complete opening must maintain its required listing.
Common Applications
Ideal for:
-
Server rooms
-
Data centers
-
Hospitals
-
Healthcare facilities
-
Schools
-
Universities
-
Government facilities
-
Stairwell doors
-
Secure offices
-
Employee-only areas
-
Pharmaceutical storage
-
Controlled laboratories
-
Institutional facilities
-
Access-controlled commercial openings
Product Specifications
Brand: ACSI
Manufacturer: Architectural Control Systems, Inc.
Model: ACL9080EU/EL-DPS
Product Type: Electrified Mortise Lock Body
Platform: Schlage L9080
Function: Electrified Storeroom / Controlled Entry
Fail Mode: Field Selectable
EU: Fail Secure / Power Unlock
EL: Fail Safe / Power Lock
Door Position Monitoring: Yes
DPS: Included
DPS Type: Magnetic Door Position Sensor
Request to Exit: No
Latch Bolt Monitor: No
Voltage: 12/24VAC/DC
Duty: Continuous
Typical Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Inside Egress: Mechanical
Outside Lever: Electrically Controlled
Key Override: With Compatible Cylinder
Lever Trim Included: No
Cylinder Included: No
What's Included
Standard configuration includes:
-
ACSI electrified L9080-style mortise lock body
-
EU/EL selectable electrical operation
-
DPS Door Position Sensor
-
DPS magnetic components required for the lock-monitoring function
-
Electrical connection components
-
Internal lock-case components
Exact factory packaging may vary.
Not Included
Unless specifically stated:
-
Exterior lever trim
-
Interior lever trim
-
Rose
-
Escutcheon
-
Mortise cylinder
-
Interchangeable core
-
Keys
-
RX Request-to-Exit switch
-
LM Latch Bolt Monitor
-
Power supply
-
Power transfer
-
Card reader
-
Keypad
-
Access-control panel
-
Door
-
Frame
-
Installation labor
Important Ordering Information
Before ordering, verify:
-
Model ACL9080EU/EL-DPS
-
DPS door-position monitoring required
-
Fail-safe or fail-secure operation
-
Supply voltage
-
AC or DC power
-
Door thickness
-
Backset
-
Lever design
-
Rose or escutcheon style
-
Cylinder format
-
Finish
-
ASA strike preparation
-
DPS magnet installation
-
Power-transfer requirements
-
Fire-rating requirements
-
Access-control monitoring inputs
Monitoring Configuration Comparison
ACL9080EU/EL
Electrified lock body only
ACL9080EU/EL-DPS
Electrified lock body + Door Position Sensor
ACL9080EU/EL-RX
Electrified lock body + Request to Exit
ACL9080EU/EL-RXDPS
Electrified lock body + Request to Exit + Door Position Sensor
Recently viewed products
Describe your recently viewed products here