ACSI ACL9080EU/EL-LMRXDPS Electric Mortise Lock | LM + RX + DPS
ACSI ACL9080EU/EL-LMRXDPS Electric Mortise Lock | LM + RX + DPS
ACSI ACL9080EU/EL-LMRXDPS Electric Mortise Lock | LM + RX + DPS
$828.85
/
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Combine electronic access control with advanced lock and door monitoring using the ACSI ACL9080EU/EL-LMRXDPS Electrified Mortise Lock Body.
Designed around the Schlage L9080 mortise-lock platform, this configuration provides field-selectable Fail Safe / Fail Secure operation along with three monitoring functions:
-
LM – Latch Bolt Monitor
-
RX – Request to Exit
-
DPS – Door Position Switch
The ACL9080EU/EL-LMRXDPS operates on 12/24VAC or DC and is designed for commercial access-control openings where the system needs to monitor not only authorized egress, but also whether the latchbolt is fully extended and whether the door is actually open or closed.
Key Features
-
Genuine ACSI – Architectural Control Systems
-
Model ACL9080EU/EL-LMRXDPS
-
Electrified commercial mortise lock body
-
Based on compatible Schlage L9080 mortise-lock architecture
-
Field-selectable:
-
EU – Fail Secure / Power Unlock
-
EL – Fail Safe / Power Lock
-
-
LM – Latch Bolt Monitor
-
RX – Request-to-Exit monitoring
-
DPS – Door Position Switch
-
12VAC
-
12VDC
-
24VAC
-
24VDC
-
Continuous-duty electrification
-
Connector included
-
Electrically controlled outside trim
-
Mechanical inside egress
-
Key override capability with compatible cylinder
-
Advanced access-control monitoring
-
Compatible with life-safety system integration
-
Lock body only – trim and cylinder sold separately
Three Monitoring Functions
The ACL9080EU/EL-LMRXDPS combines three separate monitoring functions in one electrified lock body.
LM – Latch Bolt Monitor
The Latch Bolt Monitor monitors:
Full extension of the main latchbolt
This provides the access-control system with feedback indicating whether the latchbolt has returned to its fully extended position.
LM can help determine whether the door is:
-
Properly latched
-
Not fully latched
-
Mechanically held open
-
Experiencing latch alignment problems
-
Not fully secured after closing
This provides more detailed lock-status information than door-position monitoring alone.
RX – Request to Exit
The built-in RX switch monitors operation of the inside lever.
When someone operates the inside trim to exit, the RX switch sends a signal to the connected access-control system.
RX Can Be Used To
-
Recognize authorized egress
-
Shunt door-forced-open alarms
-
Log exit events
-
Coordinate security-system logic
-
Signal access-control software
-
Distinguish authorized egress from forced entry
Important
The RX switch is a:
Monitoring Function
It does not itself electrically unlock the exterior lever.
DPS – Door Position Switch
The Door Position Switch monitors whether the door is physically:
-
Open
-
Closed
ACSI uses a magnetic sensor incorporated into the mortise-lock assembly that reacts to a corresponding magnet mounted behind the compatible ASA strike.
This eliminates the need for a separate conventional door-position contact in many applications.
DPS Can Help Identify
-
Door closed
-
Door open
-
Door held open
-
Door opened after authorized egress
-
Door remaining open beyond the programmed time
LM vs. DPS
These two monitoring functions provide different information.
DPS
Answers:
Is the door physically open or closed?
LM
Answers:
Is the main latchbolt fully extended?
A door can potentially be physically closed without the latchbolt being fully engaged.
Using both monitoring functions allows the access-control system to identify this condition.
Complete RX + LM + DPS Monitoring
Together, the three sensors allow sophisticated door-state monitoring.
Normal Secured Door
-
DPS indicates door closed
-
LM indicates latchbolt fully extended
-
RX inactive
The opening is closed and latched.
Authorized Egress
-
RX activates
-
LM changes as latch retracts
-
DPS changes when door opens
The access-control system can recognize a normal authorized exit.
Door Closed but Not Latched
-
DPS indicates closed
-
LM does not indicate full latch extension
The door may be physically against the frame but not properly latched.
This can help identify:
-
Door alignment problems
-
Strike alignment issues
-
Obstructions
-
Binding hardware
-
Door closer problems
Door Forced Open
Depending on system programming:
-
DPS changes to open
-
RX did not activate
-
No authorized entry event occurred
The access-control system may interpret this as a:
Door Forced Open
condition.
Door Held Open
If DPS remains in the open state longer than the programmed time, the access-control system may generate a:
Door Held Open
alarm.
Field-Selectable Fail Safe / Fail Secure
The electrical locking function can be configured according to the requirements of the opening.
EU – Fail Secure / Power Unlock
Power Applied = Outside Lever Unlocked
Power Removed = Outside Lever Locked
During a loss of power, the exterior side remains secured.
Fail-secure operation is commonly used where maintaining security during power failure is required.
EL – Fail Safe / Power Lock
Power Applied = Outside Lever Locked
Power Removed = Outside Lever Unlocked
During a loss of electrical power, the outside lever unlocks.
Fail-safe operation may be required for certain life-safety applications.
Important
Fail mode should be selected based on:
-
Building code
-
Fire code
-
Life-safety requirements
-
Security requirements
-
Fire alarm sequence
-
Access-control sequence
-
Authority Having Jurisdiction requirements
Electrified Storeroom-Type Operation
The ACL9080EU/EL-LMRXDPS is based on an electrified L9080 storeroom-type mortise lock function.
Typical operation includes:
Outside Lever
Electrically controlled according to the selected EU or EL mode.
Inside Lever
Provides mechanical egress and activates the RX monitoring switch.
Main Latchbolt
Monitored through the LM switch.
Door Position
Monitored through the DPS magnetic sensor.
Key Cylinder
A compatible cylinder can provide mechanical override from the exterior.
Mechanical Key Override
When equipped with the appropriate cylinder, the key can mechanically retract the latchbolt even if the outside lever is electrically locked.
Key operation does not necessarily change the electrical state of the lock.
After key operation, the lock continues to follow the access-control command.
12 / 24 VAC or DC Operation
The ACL9080EU/EL-LMRXDPS supports:
-
12VAC
-
12VDC
-
24VAC
-
24VDC
This gives installers flexibility when integrating the lock into new or existing access-control systems.
Always verify:
-
Power-supply voltage
-
Power-supply capacity
-
Wire gauge
-
Wire distance
-
Power-transfer requirements
-
Relay ratings
Continuous-Duty Electrification
The lock is designed for:
Continuous-Duty Operation
This allows the electrified locking function to remain energized for extended periods when supplied with the proper voltage and power.
Typical applications include:
-
Business-hours access control
-
Scheduled unlocking
-
Stairwell control
-
Secure offices
-
Controlled rooms
-
Institutional access systems
Access-Control Integration
The ACL9080EU/EL-LMRXDPS can integrate with compatible:
-
Access-control panels
-
Card readers
-
Keypads
-
Mobile credential readers
-
Time schedules
-
Security-management systems
-
Building-management systems
-
Fire alarm interfaces
-
Remote release controls
Advanced Door Status Monitoring
With RX, LM, and DPS signals connected to an access-control panel, the system can potentially monitor events such as:
-
Credential accepted
-
Door unlocked
-
Inside lever operated
-
Authorized egress
-
Latchbolt retracted
-
Latchbolt fully extended
-
Door opened
-
Door closed
-
Door closed but not latched
-
Door forced open
-
Door held open
Actual reporting depends on the access-control panel and programming.
Life-Safety Integration
ACSI Series 1500 electrified mortise locks are designed to interface with compatible life-safety systems.
Applications may include:
-
Fire alarm control
-
Emergency unlocking
-
Stairwell unlocking
-
Access-control systems
-
Security systems
The final system sequence must comply with applicable codes and the requirements of the complete opening.
Mortise Lock Construction
Typical L9080-platform characteristics include:
Lock Type: Mortise
Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Function: Electrified Storeroom / Controlled Entry
Inside Egress: Mechanical
Outside Access: Electrically Controlled
DPS Magnetic Monitoring
The DPS system uses a:
Magnetic Sensor in the Mortise Lock
that reacts to a:
Magnet Located Behind the ASA Strike
Proper strike and magnet alignment is important for dependable door-position reporting.
Fire-Rated Applications
Compatible electrified mortise locks may be used as part of properly listed fire-door assemblies.
For fire-rated openings, verify the complete system including:
-
Door
-
Frame
-
Mortise lock
-
Lever trim
-
Cylinder
-
Electrification
-
RX monitoring
-
LM monitoring
-
DPS monitoring
-
Strike
-
Power transfer
-
Power supply
-
Access-control system
The complete opening must maintain its required listing.
Common Applications
Ideal for:
-
Server rooms
-
Data centers
-
Hospitals
-
Healthcare facilities
-
Schools
-
Universities
-
Government buildings
-
Stair towers
-
Secure offices
-
Pharmaceutical storage
-
Laboratories
-
Employee-only areas
-
Institutional facilities
-
High-security commercial openings
-
Access-controlled doors requiring detailed status monitoring
Product Specifications
Brand: ACSI
Manufacturer: Architectural Control Systems, Inc.
Model: ACL9080EU/EL-LMRXDPS
Product Type: Electrified Mortise Lock Body
Platform: Schlage L9080-Type Mortise Lock
Function: Electrified Storeroom / Controlled Entry
Fail Mode: Field Selectable
EU: Fail Secure / Power Unlock
EL: Fail Safe / Power Lock
Latch Bolt Monitor: Yes
LM: Included
Request to Exit: Yes
RX: Included
Door Position Switch: Yes
DPS: Included
Voltage: 12/24VAC/DC
Duty: Continuous
Typical Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Inside Egress: Mechanical
Outside Lever: Electrically Controlled
Key Override: With Compatible Cylinder
Connector: Included
Lever Trim: Not Included
Cylinder: Not Included
What's Included
Standard package includes:
-
ACSI ACL9080 electrified mortise lock body
-
EU/EL field-selectable electrification
-
LM Latch Bolt Monitor
-
RX Request-to-Exit switch
-
DPS Door Position Sensor
-
DPS magnetic components as applicable
-
Electrical connector
-
Internal lock components required for operation
Exact factory packaging may vary.
Not Included
Unless specifically stated:
-
Exterior lever trim
-
Interior lever trim
-
Rose
-
Escutcheon
-
Mortise cylinder
-
Interchangeable core
-
Keys
-
Power supply
-
Power transfer
-
Card reader
-
Keypad
-
Access-control panel
-
Door
-
Frame
-
Installation labor
Important Ordering Information
Before ordering, verify:
-
Model ACL9080EU/EL-LMRXDPS
-
Fail-safe or fail-secure operation
-
Latch-monitor requirement
-
Request-to-exit requirement
-
Door-position monitoring requirement
-
Supply voltage
-
AC or DC power
-
Door thickness
-
Backset
-
Lever design
-
Rose or escutcheon
-
Cylinder format
-
Hardware finish
-
Strike preparation
-
Power-transfer requirements
-
Fire-rating requirements
-
Available access-control monitoring inputs
Monitoring Configuration
ACL9080EU/EL
Electrified lock body
ACL9080EU/EL-RX
Electrified lock body + Request to Exit
ACL9080EU/EL-RXDPS
Electrified lock body + Request to Exit + Door Position Switch
ACL9080EU/EL-LMRXDPS
Electrified lock body + Latch Bolt Monitor + Request to Exit + Door Position Switch