ACSI ACL9080EU/EL-RXDPS Electrified Mortise Lock | RX + Door Position
ACSI ACL9080EU/EL-RXDPS Electrified Mortise Lock | RX + Door Position
ACSI ACL9080EU/EL-RXDPS Electrified Mortise Lock | RX + Door Position
$725.85
/
Pickup available at NC Warehouse
Usually ready in 2-4 days
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Combine electrically controlled access with comprehensive door monitoring using the ACSI ACL9080EU/EL-RXDPS Electrified Mortise Lock Body.
Based on the Schlage L9080 mortise-lock platform, this configuration combines field-selectable Fail Safe / Fail Secure electrification with both a built-in Request-to-Exit (RX) switch and Door Position Switch (DPS).
The lock operates from 12/24VAC or DC and provides electronically controlled outside access while maintaining mechanical egress from the inside in the applicable L9080 configuration.
This listing is for the electrified mortise lock body with connector, RX monitoring, and DPS monitoring. Lever trim and cylinder are sold separately unless specifically stated.
Key Features
-
Genuine ACSI – Architectural Control Systems
-
Model ACL9080EU/EL-RXDPS
-
Schlage L9080-style mortise-lock platform
-
Electrified commercial mortise lock body
-
Field-selectable:
-
EU – Fail Secure / Power Unlock
-
EL – Fail Safe / Power Lock
-
-
RX – Request-to-Exit monitoring
-
DPS – Door Position Switch
-
12VAC
-
12VDC
-
24VAC
-
24VDC
-
Continuous-duty electrification
-
Electrical connector included
-
Electrically controlled outside trim
-
Mechanical inside egress
-
Key override capability with compatible cylinder
-
Door-position monitoring built into mortise-lock system
-
Interfaces with access-control systems
-
Interfaces with compatible life-safety systems
-
Commercial mortise-lock platform
-
Lock body only – trim and cylinder sold separately
Dual Monitoring Functions
The ACL9080EU/EL-RXDPS provides two important monitoring functions in one lock body:
RX – Request to Exit
and
DPS – Door Position Switch
Together, these allow an access-control system to determine both:
-
Whether someone is operating the inside trim to exit
-
Whether the door itself is open or closed
This provides much more complete door-status information than the standard electrified lock body alone.
RX – Request-to-Exit Monitoring
The built-in RX switch monitors use of the inside lever.
When the inside lever is operated, the RX switch changes state and sends a signal to the connected access-control system.
RX Can Be Used To
-
Recognize authorized egress
-
Shunt a door-forced-open alarm
-
Log an egress event
-
Signal a security console
-
Coordinate access-control logic
-
Integrate with other door-monitoring functions
Typical RX Sequence
-
Door is closed and secured
-
User operates the inside lever
-
RX switch changes state
-
Access-control system recognizes authorized egress
-
User exits
-
Door closes
-
System returns to its normal monitored condition
Important
The RX switch is a monitoring function.
It does not itself electrically unlock the exterior lever.
DPS – Door Position Switch
The DPS option monitors whether the door is open or closed.
ACSI's mortise-lock DPS system uses:
-
A magnetic sensor incorporated into the mortise-lock assembly
-
A corresponding magnet mounted behind the ASA strike
When the door closes and the lock approaches the strike, the magnetic relationship changes the status of the DPS circuit.
This allows the access-control system to monitor the actual position of the door.
DPS Can Help Identify
-
Door closed
-
Door open
-
Door held open
-
Door opened after authorized egress
-
Door remaining open beyond the programmed time
The exact alarm and reporting behavior is determined by the connected access-control system.
RX + DPS Access-Control Monitoring
Combining RX and DPS provides valuable information about what is happening at the opening.
For example:
Authorized Egress
RX activates + DPS changes to open
The system can recognize that someone intentionally exited through the door.
Door Open Without RX
DPS changes to open without RX activation
Depending on system programming, this may be treated as a potential:
Door Forced Open
condition.
Door Remains Open
If the DPS continues indicating an open door beyond the programmed time, the access-control system may generate a:
Door Held Open
condition.
This makes the RXDPS configuration useful for monitored commercial and institutional openings.
Field-Selectable Fail Safe / Fail Secure
The ACL9080EU/EL-RXDPS allows the electrical locking function to be selected for the opening.
EU – Fail Secure / Power Unlock
Power Applied = Outside Lever Unlocked
Power Removed = Outside Lever Locked
During a power failure, the secure side remains locked.
Fail-secure operation is commonly used where maintaining security during loss of power is important.
EL – Fail Safe / Power Lock
Power Applied = Outside Lever Locked
Power Removed = Outside Lever Unlocked
During a power failure, the secure side unlocks.
Fail-safe operation may be required on certain openings depending on life-safety and emergency-release requirements.
Important Fail-Mode Selection
Fail-safe versus fail-secure operation must be selected according to:
-
Building code
-
Fire code
-
Security requirements
-
Egress requirements
-
Access-control sequence
-
Fire alarm requirements
-
Authority Having Jurisdiction requirements
L9080-Style Electrified Storeroom Function
The ACL9080EU/EL-RXDPS is based on an electrified L9080 storeroom-type mortise-lock function.
Typical operation includes:
Outside Lever
Electrically locked or unlocked according to the selected EU/EL mode.
Inside Lever
Provides mechanical egress and activates the RX monitoring switch.
Door Position
Monitored through the integrated DPS sensor.
Key Cylinder
A compatible cylinder can provide mechanical override from the exterior.
Mechanical Key Override
A compatible mortise cylinder allows mechanical access when required.
The key can retract the latchbolt even when the exterior lever is electrically secured.
Important
Key operation does not necessarily change the electrical lock state.
After the key operation is completed, the lock continues to follow the selected electrical control logic.
12 / 24 VAC or DC Operation
The ACL9080EU/EL-RXDPS supports:
-
12VAC
-
12VDC
-
24VAC
-
24VDC
This provides flexibility when integrating the lock into commercial access-control systems.
Before installation, verify:
-
Supply voltage
-
Power-supply rating
-
Wire gauge
-
Wire distance
-
Relay capacity
-
Power-transfer requirements
Continuous-Duty Electrification
The lock is designed for:
Continuous-Duty Operation
This allows the electrified locking function to remain energized for extended periods when properly powered.
Applications include:
-
Business-hours access control
-
Scheduled locking and unlocking
-
Controlled office entrances
-
Secure rooms
-
Stairwell control
-
Institutional access-control systems
Access-Control Integration
The ACL9080EU/EL-RXDPS can integrate with compatible:
-
Card readers
-
Keypads
-
Mobile credential systems
-
Access-control panels
-
Time schedules
-
Remote release switches
-
Building management systems
-
Security-management systems
-
Fire alarm interfaces
Comprehensive Door Monitoring
The RXDPS configuration can be combined with access-control software to monitor events such as:
-
Credential accepted
-
Door unlocked
-
Inside lever operated
-
Authorized egress
-
Door opened
-
Door closed
-
Door forced open
-
Door held open
This makes the lock particularly useful where detailed audit and door-status information is required.
Life-Safety Integration
ACSI Series 1500 electrified mortise locks are designed for integration with compatible life-safety systems.
A properly designed system may coordinate with:
-
Fire alarm controls
-
Emergency-release circuits
-
Stairwell unlocking
-
Access-control panels
-
Security systems
The required behavior depends on the selected fail mode and applicable code requirements.
DPS Installation
The Door Position Switch relies on proper alignment between:
Sensor in Mortise Lock
and
Magnet at the Strike
The magnet is installed behind the compatible ASA strike so that the sensor can detect whether the door is in the closed position.
Proper alignment is essential for reliable door-status monitoring.
Mortise Lock Construction
The ACL9080EU/EL-RXDPS installs within the edge of a compatible commercial door.
Typical L9080-platform specifications include:
Lock Type: Mortise
Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Function: Electrified Storeroom / Controlled Entry
Inside Egress: Mechanical
Outside Access: Electrically Controlled
Fire-Rated Applications
Compatible L Series mortise-lock configurations may be used as part of listed fire-door openings when properly specified.
For a fire-rated application, verify the complete:
-
Door
-
Frame
-
Mortise lock
-
Lever trim
-
Cylinder
-
Electrification
-
RX monitoring
-
DPS monitoring
-
Strike
-
Power supply
-
Wiring
-
Access-control system
The complete opening must maintain its required listing.
Common Applications
Ideal for:
-
Server rooms
-
Data centers
-
Hospitals
-
Healthcare facilities
-
Schools
-
Universities
-
Government facilities
-
Stairwell doors
-
Secure offices
-
Employee-only areas
-
Pharmaceutical storage
-
Controlled laboratories
-
Institutional facilities
-
High-security commercial openings
-
Access-controlled doors requiring detailed monitoring
Product Specifications
Brand: ACSI
Manufacturer: Architectural Control Systems, Inc.
Model: ACL9080EU/EL-RXDPS
Product Type: Electrified Mortise Lock Body
Platform: Schlage L9080-Type Mortise Lock
Function: Electrified Storeroom / Controlled Entry
Fail Mode: Field Selectable
EU: Fail Secure / Power Unlock
EL: Fail Safe / Power Lock
Request to Exit: Yes
RX Switch: Included
Door Position Switch: Yes
DPS Sensor: Included
Voltage: 12/24VAC/DC
Duty: Continuous
Typical Backset: 2-3/4"
Typical Door Thickness: 1-3/4"
Inside Egress: Mechanical
Outside Lever: Electrically Controlled
Key Override: With Compatible Cylinder
Connector: Included
Lever Trim: Not Included
Cylinder: Not Included
What's Included
Standard package includes:
-
ACSI ACL9080 electrified mortise lock body
-
EU/EL field-selectable electrification
-
RX Request-to-Exit switch
-
DPS Door Position Sensor
-
DPS strike magnet components as applicable
-
Electrical connector
-
Internal lock components required for operation
Exact packaging may vary with production revisions.
Not Included
Unless specifically stated:
-
Exterior lever trim
-
Interior lever trim
-
Rose
-
Escutcheon
-
Mortise cylinder
-
Interchangeable core
-
Keys
-
Power supply
-
Power transfer
-
Card reader
-
Keypad
-
Access-control panel
-
Door
-
Frame
-
Installation labor
Important Ordering Information
Before ordering, verify:
-
Model ACL9080EU/EL-RXDPS
-
Fail-safe or fail-secure operation required
-
RX monitoring required
-
DPS monitoring required
-
Supply voltage
-
AC or DC power
-
Door thickness
-
Backset
-
Lever design
-
Rose or escutcheon style
-
Cylinder format
-
Finish
-
Strike preparation
-
Power-transfer requirement
-
Fire-rating requirements
-
Access-control monitoring inputs
-
Life-safety sequence
Important
Choose the correct version based on required monitoring:
ACL9080EU/EL
Electrified lock body only
ACL9080EU/EL-RX
Electrified lock body + Request to Exit
ACL9080EU/EL-RXDPS
Electrified lock body + Request to Exit + Door Position Switch
Recently viewed products
Describe your recently viewed products here